video corpo

Flow tester D26 SPEED
for the pharmaceutical industryfor packagingautomatic

Flow tester - D26 SPEED - Ateq - for the pharmaceutical industry / for packaging / automatic
Flow tester - D26 SPEED - Ateq - for the pharmaceutical industry / for packaging / automatic
Flow tester - D26 SPEED - Ateq - for the pharmaceutical industry / for packaging / automatic - image - 2
Add to favorites
Compare this product

Characteristics

Tested parameter
flow
Applications
for the pharmaceutical industry, for packaging
Operating mode
automatic, semi-automatic
Configuration
compact
Other characteristics
USB
Weight

1.5 kg
(3.3 lb)

Width

163 mm
(6.4 in)

Height

88 mm
(3.5 in)

Description

Without any doubt, the smallest high-performance flow tester on the market (240 parts/min).

Specially adapted for automatic and semi-automatic test machine, the D26 Speed has a full range of specifications at a very competitive price.

Valves, lighter, pneumatic and hydraulic fitting…

FEATURES

• Continuous flow measurement
• Flow rate 500 l/h – 2 bar (other range possible)
• Wide range of measurement
• 8 programs
• Set up on line via USB port
• Recalculated flow at the nominal pressure
• Air operation or in gas
• 0-10V analog output
• Controllable auto-zero
• I/O TOR
• Compact enclosure (h 163 x l 88 x P 85)
• Flexible mounting styles

ENVIRONMENT :
ROHS standard

FLEXIBLE COMMUNICATION FORMAT :

•RS232: USB, printer, PC

SPECIFICATIONS
PHYSICAL

Weight : 1.5 Kg
Dimensions : (WxHxD) 163x88x85 mm
ELECTRICAL SUPPLY

24VDC/1.6A
Main adaptater included 110 – 230 VAC
TEMPERATURE

Operating : + 5°C at + 45°C
Storage : 0°C at + 60°C
INDICATOR LIGHTS

Cycle in progress
CAN
Ethernet 24V
AIR SUPPLY

Clean and dry air
Air quality standard to be applied (ISO 8573-1)

TECHNOLOGY
Sometimes a leak can be considered as a “small flow”, or a flow as a “big leak”. When your reject level is too high for other technologies, it may be necessary to use a laminar flow tester. A flow takes place between the pressure line and the leak hole of the part.
Our instrument features a laminar flow element across which our differential pressure transducer is connected.

Every flow generates a pressure difference between the inlet and outlet of the laminar flow element, and this variation is measured by the pressure transducer.
When the fluid (gas) enters the device 1, it moves through a calibrated flow tube 2 which causes a drop in pressure. The pressure drop is measured by a differential pressure sensor 3. The pressure of the part under test 5 is measured by the sensor 4.

Catalogs

No catalogs are available for this product.

See all of Ateq‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo