video corpo

Optical spectrometer AvaSpec-NIR256-1.7-HSC-EVO
near-infraredcompacthigh-sensitivity

Optical spectrometer - AvaSpec-NIR256-1.7-HSC-EVO - Avantes - near-infrared / compact / high-sensitivity
Optical spectrometer - AvaSpec-NIR256-1.7-HSC-EVO - Avantes - near-infrared / compact / high-sensitivity
Optical spectrometer - AvaSpec-NIR256-1.7-HSC-EVO - Avantes - near-infrared / compact / high-sensitivity - image - 2
Optical spectrometer - AvaSpec-NIR256-1.7-HSC-EVO - Avantes - near-infrared / compact / high-sensitivity - image - 3
Optical spectrometer - AvaSpec-NIR256-1.7-HSC-EVO - Avantes - near-infrared / compact / high-sensitivity - image - 4
Add to favorites
Compare this product

Characteristics

Type
optical, near-infrared
Configuration
compact
Other characteristics
high-sensitivity
Wavelength

Min.: 900 nm

Max.: 1,700 nm

Length

185 mm
(7.3 in)

Width

145 mm
(5.7 in)

Height

185 mm
(7.3 in)

Weight

3.5 kg
(7.7 lb)

Description

For measurements in the near-infrared range up to 1.7 µm, Avantes offers a series of cooled spectrometer configurations. The AvaSpec-NIR256-1.7-HSC-EVO and the AvaSpec-NIR512-1.7-HSC-EVO offer the high-sensitivity 100mm optical bench (HSC) with the next generation of electronics (EVO). Both instruments deliver exceptional performance specifications, such as a high sample speed and integration times as fast as 20 μs, as the Avantes instruments you have come to trust. For applications where resolution is key or more data points for modeling are required, the 512-pixel detector will be the best choice. The AvaSpec-NIR256/512-1.7-HSC-EVO spectrometers pair the same trusted InGaAs array detectors with our ultra-low-noise electronics board, featuring a USB3 and Giga-Ethernet connection port. The instruments are equipped with a Replaceable Slit. Digital and analog I/O ports enable external triggering and control over the shutter and pulsed light sources. Choose from two distinct software-controlled gain-setting modes: high-sensitivity mode (HS, default) and low-noise mode (LN). Cooling ensures optimum noise conditions, even at longer integration times. All NIR-1.7 instruments are available with a choice of four different gratings, making it possible to choose the bandwidth fitting your application. Product Information Resolution - 1.9-32 nm Sensitivity HS in counts/µW per ms integration time - 4,800.000 (integral 1000-1750 nm) Dynamic range HS - 4900:1 Signal/noise HS - 1900:1 Integration time HS - 20 µs-500 ms Sensitivity LN in counts /µW per ms integration time - 160,000 (integral 1000-1750 nm) Dynamic range LN - 7600:1 Signal/noise LN - 5000:1

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.