Overview Put the power of versatility to work for your lab with a smart and efficient clinical chemistry analyzer solution. The AU480 chemistry analyzer is the ideal primary clinical chemistry analyzer for low- to mid-volume hospitals and laboratories, or dedicated specialty chemistry or STAT analyzer for larger laboratories. With throughput of up to 400 photometric tests per hour (up to 800 with ISEs), increased onboard testing, reduced sample volume and easy operation, the AU480 delivers efficiency for laboratories around the world.
Robust testing capabilities - Broaden your test offerings with more than 120 different Beckman Coulter system reagent applications available
- Conduct quick priority testing using the AU480 clinical chemistry analyzer’s STAT wheel
- Turn around critical samples fast with sample pre-dilution and auto-repeat of over-range results
Efficient reagent and consumable use - Minimize hands-on time and reduce daily reagent inventory tasks with ready-to-use liquid concentrated reagents
- Experience lower total cost of ownership with low consumable requirements
Convenient operational features - Provide the right operator support when needed using context-sensitive help screens and instructional videos
- Simplify operations with user-friendly graphical user interface design and touch-screen monitor
- Reduce tech-to-tech variation and achieve consistent result quality with AU family of chemistry analyzers' standardized processes
Product variants - A91961 - AU480 Chemistry Analyzer, without ISE, 210V
- A91965 - AU480 Chemistry Analyzer, with ISE, 210V
Specifications Analytical System: Fully automated, random access chemistry system with STAT capability
Analytical Principle: Spectrophotometry and potentiometry
Analytical Types: Endpoint, rate, fixed point and indirect ISE
Analytical Methods: Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE
Simultaneously Processed Analytes: 60 photometric tests + 3 ISE, 120 pre-programmed onboard tests
Throughput: 400 photometric tests/hour; maximum of 800 with ISE
ISE Throughput: 200 samples/hr. Maximum tests/hr: 600 if ISE only
Sample Types: Serum, plasma, urine, other
Sample Feeder: Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 80 samples; continuous loading
Sample Tubes: Primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm, nestled micro sample cups
STAT samples: Up to 22 positions for STAT samples via cooled turntable. Easy-to-operate interrupts between tests. Auto-repeat run capability.
Sample Volume: 1–25 μl in 0.1 μl steps (1-25 μl for repeats)
Reagent Capacity: 76 positions for (R1+R2, detergent position). Holds 15, 30 and 60ml bottles.
Reagent Storage: Refrigerated (4–12°C)
Reagent Volume: R1: 10–250 μl; R2: 10–250 μl (in 1 μl increment)
Total Reaction Volume: 90–350 μl
Reaction Cuvette: Permanent glass cuvettes
Reaction Time: Up to 8 minutes, 37.5 seconds
Reaction Incubation: 37°C, dry bath
Photometry System: Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible
Wavelength: 13 different wavelengths between 340–800 nm
Calibration: Auto calibration, cooled calibrator positions; master calibration established by two-dimensional barcode
Quality Control: Auto QC, cooled QC positions
Rerun: 1. Auto rerun and manual rerun available; 2. Automatic sample increase, decrease or normal repeat; 3. Reflex testing
Sample Pre-dilution: Dilution ratio: Fixed to 3, 5, 10, 15, 20, 25, 50, 76 or 100
Test Requisition: Individual and profile test requisition via online, mouse, function keys and touch-screen
Sample Integrity: Lipaemia, Haemolysis and Icterus analysis. Sample clot detection and probe crash protection.
Online: RS232C. Full uni- and bidirectional communication possible.
Software: Windows 7®
Data Storage: Sample number 100,000 samples. Reaction Data 200,000 tests.
Dimensions (W x H x D): ANL: 1450 mm x 1205 mm x 770 mm
Power Supply: 100–240v; 60 Hz/ < 3.5 kVA
Caractéristiques / Spécifications techniques - Analytical System: Fully automated, random access with STAT capability
- Throughput: Up to 400 photometric tests/hour (up to 800 with ISE)
- Simultaneously processed analytes: 60 photometric + 3 ISE; 120 onboard tests
- Sample types: Serum, plasma, urine and others
- Sample volume: 1–25 μl (0.1 μl steps)
- Reagent capacity: 76 positions; refrigerated storage (4–12°C)
- Reaction cuvette: Permanent glass cuvettes; reaction volume 90–350 μl
- Wavelengths: 13 wavelengths between 340–800 nm
- Software: Windows 7
- Data capacity: 100,000 samples; 200,000 reaction data entries
- Dimensions: ANL 1450 x 1205 x 770 mm
- Power: 100–240 V, 60 Hz, < 3.5 kVA