• Products
  • Catalogs
  • News & Trends
  • Exhibitions

Automatic biochemistry analyzer AU200
benchtoprandom accesswith ISE

Automatic biochemistry analyzer - AU200 - Beijing Strong Biotechnologies, Inc - benchtop / random access / with ISE
Automatic biochemistry analyzer - AU200 - Beijing Strong Biotechnologies, Inc - benchtop / random access / with ISE
Add to favorites
Compare this product

Characteristics

Operation
automatic
Configuration
benchtop
Technology
random access, with ISE
Throughput

200 p/h

Sample volume

Min.: 0.002 ml
(0.000068 US fl oz)

Max.: 0.05 ml
(0.001691 US fl oz)

Number of sample positions

40 unit

Reagent volume

Min.: 0.01 ml
(0 US fl oz)

Max.: 0.45 ml
(0.02 US fl oz)

Number of reagent positions

40 unit

Weight

50 kg
(110.2 lb)

Length

720 mm
(28.3 in)

Height

550 mm
(21.7 in)

Description

Designed for precision, speed, and reliability, the AU200 offers: ✔️ Random access for fast results ✔️ 50 high-transmittance reaction cuvettes ✔️ Built-in auto water blank test for accuracy ✔️ Real-time monitoring for sample & reagent status ✔️ Easy-to-use interface with multi-language support Perfect for modern laboratories aiming for high throughput and efficiency! Specifications Waler Consumption - Low - to - 5L/Hour Maximum Reaction Time - 14 minutes (Single reagent). 10 minutes(Dual reagent) Maximum Reaction Volume - 400 uL Testlng Mode - Regular mode(single&dual reagents), (ast mode(single reagent) Sample Mode - Random access. STAT sample prkyity Stability - <0.01Abs/hour CV - <1.5% Conter Wavelength Deviation - ±2nm Detector - Photodiode detector array Calibration Mode - One point linear, two point linear. multi-poml linear. Logit-4P, Logit-5P. sptine, exponential. polynominal Calibration Curve - Calibration curvo auto check. auto curvo fltting QC Rule - Westgard multi-rule. Cumulative sum check. Twin Plot QC Curve - Westgard multi-rule, Cumulative sum check, Twin Plot QC Warning - Out of control auto warning. data automatic record and analysis Operating System - Windows 7/10 Data Storage - Decided by computer hard dise capacity LIS Interface - Bi-LlS interface Phni Mode - Multi - default - formats, - user - defmed - formats Real time monitoring for sample disk, reagent disk, reaction disk. Real time monitonng for QC status. Real time monitoring for reaction cuvettes status, lamp status and température. Real time monitoring for reagent volume, reaclion curve, calibration curve and QC curve. Linearity range limitation,
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.