- Laboratory >
- Laboratory medicine >
- Stain reagent
Stain reagents
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

... coded calibration buffers, you always know you have the right solution in hand. These solutions do not contain any dyes that may stain the reference cell of a pH electrode. Condition for longer pH ...

Mindray's hematology controls and calibrators are the original standards with which to evaluate the precision and accuracy of hematology analyzers. Backed up by world-class development and manufacturing, these hematology controls and ...

... demanding cases. The genetic analysis is calibrated with BT5 Matrix. The Investigator Triplex AFS QS Kit is for forensic stain pre-selection, which serves as a starting point for genotyping strategies. It enables simultaneous ...

... single, cost-effective competition assay using IgG-capture beads, IgG fluorescent competing antibody, and a cell viability stain. Clone productivity ranking with more relevant data—Balancing IgG concentration, cell ...
Sartorius Group

... -and-read kit utilizes a DNA binding dye that fluoresces in proportion to DNA content for creating of cell cycle profiles and quantifying relative percentages of cells in each cell cycle phase. The DNA-selective dye ...
Sartorius Group

Sartorius offers a range of reagents, kits and consumables specifically designed around your application needs to enable long-term, kinetic live-cell imaging and analysis. Obtain specific and robust measurements of cell ...
Sartorius Group

Combines the components of the Alcian Blue and Periodic Acid Schiff (PAS) stain kits. Alcian Blue is normally prepared at an acidic pH of 2.5 PAS staining is mainly used for staining structures containing a high ...
Leica Biosystems

EA-65 is a light green, alcohol-based stain primarily used in the cytology laboratory for routine cytoplasmic staining. Available in various quantities.
Leica Biosystems

Three Gill formulations are available: The Gill I formula is generally recommended for cytology. The stronger Gill III is usually preferred for use in histology. GIll II is a medium strength hematoxylin. The Gill ...
Leica Biosystems

Storage temperature: 2 °C - 8 °C
... methods of quantitating protein rely either on Coomassie dye binding or protein-catalyzed reduction of cupric (Cu2+) ion to cuprous (Cu+) ion. Dye-binding assays cannot be used in the presence of any reagent ...

Bio-Optica marking dyes are special, non-toxic inks, made with natural polymers, used to mark surgical margins. The advantages of using Bio Marking Dyes are as follows: - They are non-toxic and made ...
BIO-OPTICA Milano

... . PRINCIPLE Sirius red picrate solution performs a double function: - to stain collagen by the binding between Sirius red and some proteins containing basic amino acids - to stain bilirubin by conjugation ...
BIO-OPTICA Milano

Packaging - 05-M05015 Primary container: white bottle in High Density Polyethylene (HDPE). Useful capacity 500 ml. HDPE cap. Tamper evident cap. - 05-05015/L Primary container: white bottle in High Density Polyethylene (HDPE). Useful ...
BIO-OPTICA Milano

Storage temperature: -70 °C - -20 °C
Purity: 99 % - 99 %
The basement membrane is a matrix under the basal surface of epithelial cells of animals. Scilia Extragel Matrix is a reconstituted matrix hydrogel formed by basement membrane components extracted from mouse tumor tissues. This matrix ...

Storage temperature: 10 °C - 30 °C
... of acidity, and it has a strong affinity with the basic stain(hematoxylin), while the cytoplasm is on the contrary, which has a certain degree of basicity and a strong affinity with the acid stain(eosin). ...
Dakewe (Shenzhen) Medical Equipment Co., Ltd.

Storage temperature: 10 °C - 30 °C
... of acidity, and it has a strong affinity with the basic stain (hematoxylin), while the cytoplasm is on the contrary, which has a certain degree of basicity and a strong affinity with the acid stain (eosin). ...
Dakewe (Shenzhen) Medical Equipment Co., Ltd.

Storage temperature: 10 °C - 30 °C
... called H&E (Hematoxylin and Eosin). H&E mainly contains the two dyes hematoxylin and eosin. Hematoxylin are often employed to color the nuclei of cells blue. Eosin is an acidic dye, it stains cytoplasm ...
Dakewe (Shenzhen) Medical Equipment Co., Ltd.

Inert yellow dye helps reduce pipetting errors Room temperature stable for up to 30 days Compatible with fast cycling protocols Highly sensitive for low copy number templates Includes Accuris Hot Start ...
BENCHMARK SCIENTIFIC

... of a variety of templates including low copy number and difficult sequences, while the proprietary qMax Green intercalating dye exhibits higher fluorescence and lower PCR inhibition than other popular green dyes. These ...
BENCHMARK SCIENTIFIC

... , 100bp and 1kb – to cover most common applications. Ready-to-use formulation includes loading buffer and tracking dye 500µl suitable for 100 lanes (5µl per lane) Higher intensity reference bands ...
BENCHMARK SCIENTIFIC

... nitrocellulose membrane or PVDF membrane, it could effectively detect the result of transfer proteins. The traditional way is to stain proteins with Ponceau S, which not only has the low sensitivity, but also fast discoloration ...

Storage temperature: -20 °C
Purity: 85 %
... Calibration is a preliminary step meant to adjust spectral profile for each single dye on the qPCR platforms. This allows to compensate for crosstalks between dyes (channels) in the context of multiplexed ...
Eurogentec

Storage temperature: -20 °C
Purity: 85 %
... Calibration is a preliminary step meant to adjust spectral profile for each single dye on the qPCR platforms. This allows to compensate for crosstalks between dyes (channels) in the context of multiplexed ...
Eurogentec

Storage temperature: -20 °C
The Fluorescein Passive Reference consists of an inert dye whose fluorescence is stable along the qPCR reaction, allowing the normalization of well-to-well variations that may result from pipetting errors or instrument ...
Eurogentec

Storage temperature: -20 °C
Fast single- and multiplex endpoint PCR assays! PCR results in 20 minutes. Reliable results in single and multiplex reactions. Stable for 2 months at room temperature. Robust performance. Suitable Sanger sequencing applications. Description SolisFAST® ...
Solis BioDyne

Storage temperature: -20 °C
... Concentration: 5x Hot-start: yes, 2 minutes initial incubation at 98 °C Ready-to-load: yes, includes two loading dyes Cloning Type: T/A cloning Amplicon Size: up to 5 kb Targets: 1-18 targets, depending ...
Solis BioDyne

Storage temperature: -20 °C
Fast single- and multiplex endpoint PCR assays! PCR Results in 20 minutes. Analyze one or multiple targets per reaction. Contains dUTP and UNG to prevent carryover contamination. Reliable results in Sanger sequencing applications. Description SolisFAST® ...
Solis BioDyne

... Fluorescein-Conjugated Goat IgG to Mouse Complement C3 is intended for laboratory use to qualitatively stain sections of frozen tissue, suitable for use as a reagent in immunofluorescence assays (IFA), ...

... immunoelectrophoresis because of the large pore size for rapid diffusion and for low background staining by Coomassie Blue G stain. The low EEO and high gel strength is specifically selected and tested for immunoelectrophoresis ...

... blue is also recommended for use in dye exclusion procedures for viable cell counting. Non-viable cells will up-take trypan blue at a faster rate than viable cells. Application Notes Trypan Blue is used as a vital ...

Storage temperature: 2 °C - 8 °C
... various types of automatic immunohistochemistry stainer. Reagent Composition MicroStacker™ Flex HRP-Polymer Detection Kit(Mouse Linker) Code: SD5100 (6 Components) Peroxidase Blocking Reagents Mouse ...
Celnovte Biotechnology Co., Ltd.

Storage temperature: 2 °C - 8 °C
... detection kit is suitable for various types of automatic immunohistochemistry stainer. Reagent Composition Code: SD5201 (6 Components) Peroxidase Blocking Reagents Linker MicroStacker™ HRP-Polymer 20*DAB ...
Celnovte Biotechnology Co., Ltd.

Storage temperature: 2 °C - 8 °C
... with the HRP polymer at a higher degree of polymerization, thus higher sensitivity. Reagent Composition Code: SD3202(5 Components) Peroxidase Blocking Reagents MicroStacker™ Anti-Mouse/Rabbit HRP-Polymer 20*DAB ...
Celnovte Biotechnology Co., Ltd.

Storage temperature: 4 °C
... of Coomassie brilliant blue dye to proteins at arginine, tryptophan, tyrosine, histidine, and phenylalanine residues. Specifically, the anionic dye binds to these residues producing an absorbance maximum ...
Bioquochem

... blue colour) after adding the reagents to samples containing ionic iron. Additional information Sizes: 100 and 200 tests Expiry date: 1 year Storage: Room temperature Reagents: Reagent ...
Bioquochem

Storage temperature: 2 °C - 8 °C
Schiff reagent solution is a ready-to-use solution used in the staining technique Periodic Acid Schiff (PAS). PAS is used to demonstrate simple polysaccharides, neutral muco-polisaccharides, mucoproteins, glycolipids, ...
Bioquochem

... 445, 465, 495, 525, 545, 565 and 595. With this size standard, your own custom marker fragments can be labeled with the dyes FAM™, VIC®, NED™ or PET® (G5 filterset, Life Technologies) or with FAM™, ZEL™, SOL™, FER™ ...
NimaGen B.V.

... 400, 450, 490 and 500 bp. With this size standard, your own custom marker fragments can be labeled with three different dyes , for example FAM™, VIC® , NED™ or TAMRA®. Each kit contains sufficient standard for at ...
NimaGen B.V.

... adopted as proven, high-quality reagents for laboratories using 310, 3100, 3130, 3500, 3730 Series Genetic Analyzers and SeqStudio™. Premium features BrilliantDye™ Terminator (v3.1) Cycle Sequencing Kit provides the ...
NimaGen B.V.

... fluorescent dye • Unique buffer system and antibody-mediated hot start enzyme • Early Cq, high RFU, and reduced primer-dimer formation • Convenient 2x concentrated premix • Fast, specific, sensitive, and reliable • ...

... amplification DIRECTLY from whole blood, animal, and plant tissues • Skip DNA purification • Applicable with intercalating dyes and probes • TIME and COST saving • Point-of-care diagnostic applications The RealHelix™ ...

... separately supplied ROX dye could be used as a passive reference dye with real-time PCR instruments that are compatible with the evaluation of the ROX signal. Contents • QRT Enzyme Mix [Green] • ...

... method in a routine hematoxylin and eosin (HE) staining in histology. Does not contain mercury oxide because of its toxicity; stains nuclear membrane, nucleoplasm and nucleolus exceptionally well.
Histo-Line Laboratories

Eosin Y solution in an alcohol-based, ready-to-use is a stain used primarily in histology for routine hematoxylin and eosin staining.. When used correctly, various shades of pink can be obtained to aid in visualization ...
Histo-Line Laboratories

Hematoxylin Mayer is one of the formulations of hematoxylin used in histopathology and immunohistochemistry for a more precise nuclear cell staining. It is applied progressively in a routine hematoxylin and eosin (HE) staining and ...
Histo-Line Laboratories

Storage temperature: 2 °C - 25 °C
... glutaric acid and methylresorufin.The color intensity of the red dye formed is directly proportional to the lipase activity. This activity can be measured at 578 nm. PRECAUTIONS 1. The reagents ...

Storage temperature: -20 °C
Magigen MagicScript LAMP amplification kits are one-step solution for Loop-Mediated Isothermal Amplification(LAMP) of DNA targets. The LAMP kits contain fluorescent dye, dNTPs, metal ion indicators for LAMP amplification. Introduction Magigen ...

Storage temperature: 4 °C
... Nucleic Acid Loading Dye, you do not need to add any dye to both gel matrix and running buffers. The dye is provided in a form of 6X sample loading dye and it is to be added to your sample ...
Maestrogen

2X DirectGO PreMix-CE is a premixed ready-to-use solution containing reaction buffer, dNTPs, loading dye, glycerol, PCR enhancers and Hot Start Taq DNA polymerase as 2-fold concentration. Comparing with conventional Taq polymerase, ...

... activity at temperature lower than 50°C. By using 2X ExpressGO PreMix-CE, “hot start PCR” can be achieved without any additional reagents or procedures. Thus, 2X ExpressGO PreMix-CE can easily amplify 5 kb DNA fragment ...

... Green Advance MIDORI Green Advance is a safe alternative to the traditional nucleic acid stain ethidium bromide. It is a non-carcinogenic and less mutagenic dye for detecting dsDNA, ssDNA and RNA in ...
Nippon Genetics

Storage temperature: -20, 4 °C
... yield and also reliable DNA amplification. Taq DNA Polymerase RED is a good alternative to Ampliqon Taq DNA Polymerase. The red dye in this product provides convenient identification of enzyme addition to the tube and ...
Ampliqon A/S
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining