Product typeCardiac Resynchronization Therapy Pacemakers (CRT‑P). VISIONIST™ X4 and VALITUDE™ X4 are MR‑conditional when used as part of the ImageReady™ MR‑Conditional Pacing System and when MRI Conditions of Use are met for 1.5T and 3T scans.
Key resources- Directions for Use
- ImageReady MR‑Conditional Pacing Systems
- RightRate™ Minute Ventilation Brochure
- Indications, Safety and Warnings
Product features- RightRate™ Respiration‑Based Pacing — Included on VISIONIST™ models to provide minute‑ventilation sensing for chronotropic responsiveness.
- ImageReady™ MR Conditional Systems — Support 1.5T and 3T Full Body MRI scans when MRI Conditions of Use are satisfied.
- 17 Pacing Vector Options — Offer flexibility to optimize left‑ventricular lead configuration, manage phrenic nerve stimulation and pacing thresholds.
- Battery Technology — 1.6 Ah EL battery technology with labeled longevity range of approximately 6.7 to 13.8 years.
- Atrial Arrhythmia Report — Provides comprehensive AT/AF status to inform AF treatment assessment.
- Automatic Daily Monitoring — Supports automatic daily monitoring with the LATITUDE™ NXT Patient Management System to improve clinic workflow.
- Post‑Operative System Test (POST) — Fully automatic evaluation of lead impedances, intrinsic amplitudes and capture thresholds prior to discharge.
- SmartDelay™ AV Delay Optimization — Adjusts paced and sensed AV delays to promote electrical fusion and optimize hemodynamic performance.
Mechanical specifications and documentationSpecification sheets are available for VISIONIST™ X4 CRT‑P and VALITUDE™ X4 CRT‑P. Detailed documents describe device dimensions, battery, electrical and pacing characteristics as published in the product specification sheets.
ReimbursementRhythm Management reimbursement resources are available to support coding and reimbursement for CRT‑P therapy.
Technical specifications- Device type: Cardiac Resynchronization Therapy Pacemaker (CRT‑P)
- Commercial designation / models: VISIONIST™ X4 and VALITUDE™ X4
- MRI conditionality: MR‑conditional for 1.5T and 3T when used as part of the ImageReady™ MR‑Conditional Pacing System and when MRI Conditions of Use are met
- RightRate™ sensor: Minute‑ventilation respiration‑based sensor included on VISIONIST™ models (supports chronotropic competence)
- Pacing vectors: 17 pacing vector options to optimize therapy and manage phrenic nerve stimulation and thresholds
- Battery: 1.6 Ah EL battery technology; labeled longevity approximately 6.7–13.8 years
- Monitoring & connectivity: Automatic daily monitoring supported with LATITUDE™ NXT Patient Management System
- Diagnostics & reports: Atrial Arrhythmia Report for AT/AF assessment; Post‑Operative System Test (POST) for automatic lead check prior to discharge
- AV optimization: SmartDelay™ AV delay optimization to promote electrical fusion and hemodynamic performance
- Available documentation: Directions for Use, RightRate brochure, VISIONIST™ and VALITUDE™ specification sheets, Indications/Safety/Warnings