Cubic MED-MZ001 is a multi-anesthesia sensor developed for simultaneous and continuous monitoring of anesthetic agents including Sevoflurane, Desflurane, and Isoflurane, as well as N2O and CO2 in patient respiratory gases. Utilizing advanced NDIR (Non-Dispersive Infrared) technology, MED-MZ001 provides high-precision measurements with rapid response. It features strong resistance to cross-gas interference, ensuring accurate measurements in complex gas mixtures. Equipped with integrated pressure and temperature compensation algorithms, MED-MZ001 delivers reliable measurements across varying environmental conditions. Its compact design enables seamless integration into anesthesia machines. MED-MZ001 provides a precise and reliable solution for anesthesia gas monitoring in operating rooms and critical care environments.
- NDIR (Non-Dispersive Infrared) technology
- Simultaneous detection of Sevoflurane, Desflurane, Isoflurane, N2O, and CO2 concentrations
- Strong resistance to cross-gas interference
- High accuracy measurement
- Fast Response Time
- Long-term stability
- Compact and lightweight design
Detecting Principle: NDIR (non-dispersive infrared) technology
Measurement gas: Sevoflurane (C4H3F7O), Desflurane (C3H2F6O), Isoflurane (C3H2ClF5O), CO2, N2O
Measurement Range: Sevoflurane: 0 - 8 %Vol; Desflurane: 0 - 18 %Vol; Isoflurane: 0 - 5 %Vol; CO2: 0 - 15 %Vol; N2O: 0 - 100 %Vol
Accuracy: Sevoflurane, Desflurane, Isoflurane: ±(0.15% Vol + 5% of reading); CO2: ±(0.2% Vol + 2% of reading); N2O: ±(2 %Vol+ 2% of reading) @ N2O ≤85%Vol
Resolution: Sevoflurane, Desflurane, Isoflurane: 0.15% Vol; CO2, N2O: 0.1% Vol
Sampling Frequency: 100Hz
Startup Time: ≤30s
Response time: Sevoflurane, Desflurane, Isoflurane: T90< 600ms; CO2, N2O: T90< 250ms
Sampling method: Suction; Air pump
Protection Level: IP65
Output: RS232
Dimensions: 45.5mm x 32.0mm x 29.5mm
Lifetime: ≥10 years
Shell Material: Photosensitive resin
Working Temperature: 10 ~ 40°C (50 - 104°F)
Storage Temperature: -25 ~ 60°C (-13 - 140°F)
Working Humidity: 10-98%RH (non-condensing)
Storage Humidity: 10-90%RH (non-condensing)
Working Pressure: 660~1060mbar (with pressure compensation)
Storage Pressure: 500~1060mbar
Power Supply: 5V±5% DC
Average Working Current: <300mA (@25°C, 5V)
Remarks:
- The sensor can simultaneously detect anesthetic gas (one of sevoflurane, desflurane, isoflurane) and CO2, N2O concentrations.
- The response time is measured by passing 120mL/min of gas into the sensor at a background gas concentration of 60% of the full scale.
- The current is measured at room temperature condition, and it may vary at high temperature or low temperature condition.
Technical Specifications:
- Detecting Principle: NDIR (non-dispersive infrared) technology
- Measurement gases: Sevoflurane, Desflurane, Isoflurane, CO2, N2O
- Measurement Ranges: Sevoflurane: 0-8%Vol; Desflurane: 0-18%Vol; Isoflurane: 0-5%Vol; CO2: 0-15%Vol; N2O: 0-100%Vol
- Accuracy: Sevoflurane/Desflurane/Isoflurane: ±(0.15%Vol + 5% of reading); CO2: ±(0.2%Vol + 2% of reading); N2O: ±(2%Vol + 2% of reading) @ N2O ≤85%Vol
- Resolution: Sevoflurane/Desflurane/Isoflurane: 0.15%Vol; CO2/N2O: 0.1%Vol
- Sampling Frequency: 100Hz
- Startup Time: ≤30s
- Response Time: Sevoflurane/Desflurane/Isoflurane: T90<600ms; CO2/N2O: T90<250ms
- Sampling Method: Suction; Air pump
- Protection Level: IP65
- Output: RS232
- Dimensions: 45.5mm x 32.0mm x 29.5mm
- Lifetime: ≥10 years
- Shell Material: Photosensitive resin
- Working Temperature: 10~40°C (50-104°F)
- Storage Temperature: -25~60°C (-13-140°F)
- Working Humidity: 10-98%RH (non-condensing)
- Storage Humidity: 10-90%RH (non-condensing)
- Working Pressure: 660~1060mbar (with pressure compensation)
- Storage Pressure: 500~1060mbar
- Power Supply: 5V±5% DC
- Average Working Current: <300mA (@25°C, 5V)