Digital veterinary X-ray system RV-32AL
digitalwith table

Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table
Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table
Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table - image - 2
Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table - image - 3
Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table - image - 4
Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table - image - 5
Digital veterinary X-ray system - RV-32AL - Dawei Medical - digital / with table - image - 6
Add to favorites
Compare this product

Characteristics

Technology
digital, digital
Ergonomics
with table

Description

Product Overview
RV-32AL is an animal / veterinary digital radiography (DR) system designed for fast, consistent, and low‑dose X‑ray imaging in veterinary clinics and pet hospitals. It combines a 32kW high‑frequency generator (200 kHz), a CsI flat panel detector, and intelligent DR software to support daily radiology workflows — from routine chest and orthopedic exams to abdominal and contrast studies.

Key Benefits (Why RV-32AL)
  • High stability for reliable daily DR use: Detector “zero-disconnect” design concept helps reduce common DR interruptions and keeps exams moving; long-term performance stability helps extend service intervals and lower total cost of ownership.
  • Low-dose veterinary X‑ray imaging: Up to 30% lower dose compared with traditional X‑ray systems (as stated); high-frequency generator (200 kHz) improves beam quality and supports low‑dose imaging; suitable for sensitive patients (young animals, pregnant animals, or cases requiring follow-up imaging).
  • Fast imaging to reduce animal stress: Full workflow in ~5 seconds from exposure to image display; detector preview time < 3 seconds.
  • High image quality for confident diagnosis: 16‑bit A/D for richer grayscale detail; 3.6 lp/mm spatial resolution for clear visualization of subtle lesions; AED (Automatic Exposure Detection) helps reduce retakes.

Smart DR software & connectivity
Built-in tools include WW/WL, measurement, annotation and more. DICOM 3.0 support for integration with PACS / HIS / RIS. Automatic calibration function to help keep exposures accurate. Supports large case storage for comparison and teaching.

Clinical Applications (Veterinary Radiology)
  • Chest X‑ray (thoracic radiography): pneumonia, cardiomegaly, mediastinal disease.
  • Orthopedic X‑ray: fracture, luxation, bone tumor localization.
  • Abdominal X‑ray: GI foreign body, obstruction, reproductive system assessment.
  • Contrast studies: digestive tract and urinary system imaging.

Technical Specifications
High‑Voltage Generator
Item — Specification
Output power — 32 kW
Rated input — 220 VAC ±10%, 50 Hz
Inverter frequency — 200 kHz ±10%
Exposure kV range — 40–150 kV
Exposure mA range — 10–400 mA
Exposure time range — 1–10,000 ms
Exposure mAs range — 0.1–320 mAs
Exposure techniques — kV‑mAs; kV‑mA‑ms
APR — Up to 2000 APR data sets
Communication — RS‑232
Auxiliary power — +24V DC 2A; 24V AC 8A

Flat Panel Detector (FPD)
Item — Specification
Detector technology — a‑Si (amorphous silicon)
Scintillator — CsI (cesium iodide)
Pixel matrix — 3072 × 3072
Pixel size — 139 μm
A/D conversion — 16‑bit
Spatial resolution — 3.6 lp/mm
Active imaging area — 404 mm × 404 mm
Detector size — 474 × 474 × 22.5 mm
Data interface — Gigabit Ethernet
Trigger modes — Soft trigger / Prep
Preview time — 3 s
Imaging time — 5 s
Weight — 3.5 kg
Power consumption — 220 W

Collimator
Item — Specification
Control — Manual
Max energy — 150 kV
Inherent filtration — 1 mm Al
Field size @ SID 100 cm — Min 2 × 2 cm; Max 43 × 43 cm
Field error — ≤ 1% of SID
X‑ray field error — ≤ 1% of SID
Light exposure time — 30 s
LED brightness @ SID 100 cm — ≥ 18,000 lux
Leakage (EN60601‑1‑3) — < 0.5 mGy/h
Power supply — 24V AC/DC, Max 4A
Size — 206 × 230 × 143 mm
Weight — 7.0 kg ±0.5 kg

X‑Ray Tube Assembly
Item — Specification
Max tube voltage — 125 kV
Focal spot — 1.0 mm (small) / 2.0 mm (large)
Max power — 20 kW (small) / 40 kW (large)
Anode heat capacity — 140 kHU

What’s Included / Options
  • Standard configuration: RV‑32AL DR system (table + stand), high‑voltage generator, X‑ray tube assembly, collimator, flat panel detector, DR software.
  • Optional / configurable items: workstation PC, displays, DICOM networking setup, clinic integration (PACS/HIS/RIS), training & installation services.

Catalogs

No catalogs are available for this product.

See all of Dawei Medical‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.