Humidity analyzer ProFoss™ 2 Dairy
controlfor milkcontinuous

Humidity analyzer - ProFoss™ 2 Dairy - FOSS - control / for milk / continuous
Humidity analyzer - ProFoss™ 2 Dairy - FOSS - control / for milk / continuous
Humidity analyzer - ProFoss™ 2 Dairy - FOSS - control / for milk / continuous - image - 2
Humidity analyzer - ProFoss™ 2 Dairy - FOSS - control / for milk / continuous - image - 3
Humidity analyzer - ProFoss™ 2 Dairy - FOSS - control / for milk / continuous - image - 4
Add to favorites
Compare this product

Characteristics

Tested parameter
control, humidity
Applications
for milk
Operating mode
continuous
Configuration
in-line
Tested marker
protein, lipid
Other characteristics
digital, in-situ
Analysis duration

Min.: 2 s

Max.: 3 s

Weight

25 kg
(55.1 lb)

Width

420 mm
(16.5 in)

Height

135 mm
(5.3 in)

Description

Overview
The ProFoss™ 2 Dairy is an inline dairy process analyser for continuous, real-time monitoring of dairy production. It supports a wide range of dairy products — from butter and cream to cheeses, Greek yogurt, mozzarella and dairy powders — enabling tighter process control and consistent product specifications.

Features
  • Value: Enables operation closer to targets, improves batch-to-batch consistency, optimises key parameters and reduces rework.
  • Sample type: Butter, fresh cheese, Greek yogurt, mozzarella, WPC/MPC, cream and dairy powders*.
  • Parameters: Fat, protein, moisture, total solids, solids non-fat (SNF) and protein-to-total-solids ratio.


Highlights
  • 3rd generation lateral transmittance: A lengthwise probe in the pipe measures from the core of the product using near infrared transmittance to penetrate deeper than surface-only methods.
  • Performance validation: Reduce error risk by validating ProFoss™ 2 predictions against a benchtop analyser without manual entry; matched results are saved for evaluation and reporting via digital services.
  • Trend analysis: Direct inline measurements minimise sampling and preparation errors; high-frequency readings (every few seconds) and intuitive graphical displays reveal process variation in real time.
  • High-resolution NIR: Diode array detector with fine spectral dispersion secures detailed and repeatable analysis results.


Applications and product variants
  • ProFoss™ 2 Butter: Continuous, direct measurements to improve yield and profitability in butter production.
  • ProFoss™ Dairy Powder: Continuous inline analysis for improved control and profit in dairy powder production.


Technical specification
Measuring Technology : Lateral Transmittance
Analysis frequency : Real time — average analysis time per result 2–3 seconds
Wavelength range : 850–1050 nm
Detector : Si Diode Array
Spectral dispersion : 1.0 nm/pixel
Optical fiber protection : Steel armoured (available lengths: 1, 3, 5 or 10 meters)
Process line interface : Sapphire process window 5 mm thick with food-grade FFPM O-ring seal; fits standard Varinline access units (Ø68 mm or Ø50 mm) or FOSS stainless steel welding
Product temperature : Max 150°C (302 °F)
Product pressure : Production pressure < 30 bar (< 435 PSI); Shock pressure < 75 bar (< 1088 PSI). Note: Varinline access units larger than DN 80 permit a maximum pressure of 10 bar (145 PSI)
Technology (general) : NIR technology
Software package : ISIscan™ NOVA for instrument control
Wavelength accuracy : < 0.5 nm
Wavelength precision : < 0.02 nm
Wavelength temperature stability : < 0.01 nm/°C
Spectral Noise : < 60 micro AU
Vibrations (require optical fiber fixation) : 0.4 Grms
Ambient operating temperature : ProFoss™ 2: -5°C to 40°C (23 °F to 104 °F); cooling with compressed air allows use up to 65°C (149 °F) | ProFoss™ 2 Ex: ATEX / IECEx: 0°C to 50°C (32 °F to 122 °F); cULus: 0°C to 40°C (32 °F to 104 °F)
Pressurised air – cooling (Amb. Temp. 45 - 65°C) : Cooling air flow rate minimum 5 l/min, >99.9% water free, >99.9% free of oil and fine particles down to 0.3 μm
Ambient humidity : < 90% RH
Dimensions (W x D x H) : 420 x 420 x 135 mm (16.5 x 16.5 x 5.3 inches) + brackets
Weight : 25 kg (55.1 lb)
Cabinet / Housing materials : 1.5 mm (lid 2.5 mm) Stainless Steel EN 1.4301 (SS2333)
Mechanical environment : Process control equipment
Degree of protection : ProFoss™ 2: IP69* | ProFoss™ 2 Ex: IP6X
Approvals : ProFoss™ 2: CE | ProFoss™ 2 Ex: CE, ATEX, IECEx and cULus certified (dust explosion approved)
Hygiene : 3-A hygiene and EHEDG hygiene certified
Communication : KEPServerEX (Ethernet, Analogue, Profibus/Profinet) to PLC/SCADA; FOSS IQX™
Network : High quality, shielded LAN cable; minimum category 5e. RJ45 (IP67) LAN connections
Power supply : 1 phase, 100–240 VAC (max ±10% of rated voltage), max. 40 VA, 50–60 Hz
Operation : Indoor use or outdoor shielded from rain and direct sunlight

Technical specifications
  • Measuring technology: Lateral transmittance (NIR)
  • Analysis time: 2–3 seconds per result (real time)
  • Wavelength range: 850–1050 nm; Si diode array detector; 1.0 nm/pixel spectral dispersion
  • Sapphire process window 5 mm with food-grade FFPM O-ring
  • Max product temperature: 150°C; production pressure < 30 bar; shock pressure < 75 bar
  • Ambient operating temperature: -5°C to 40°C (standard); optional cooling for up to 65°C; Ex variants available with specified ranges
  • Protection: IP69 (standard); Ex version IP6X
  • Approvals: CE; Ex versions: ATEX, IECEx, cULus
  • Hygiene certifications: 3-A and EHEDG
  • Dimensions: 420 x 420 x 135 mm; Weight: 25 kg
  • Communications: Ethernet/PLC/SCADA integration and FOSS IQX™ digital services

Catalogs

No catalogs are available for this product.

See all of FOSS‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.