Product DescriptionProduct Name: Anesthesia Laryngoscope
Main structural ComponentsThe anesthesia laryngoscope consists of a blade and handle. It features an LED light source with fiber-guide beam illumination. The product is reusable.
Applicable scope and applicable peopleScope of application: Used to assist tracheal intubation during clinical anesthesia or emergency care.
User group: Intended for clinicians performing tracheal intubation in anesthesia and emergency settings.
Representative product — Fiber Optic Model- Conduction principle: Light is conducted via fiber optic light guide as a cold light source.
- Position of the bulb: LED bulb located at the front of the handle for prolonged use.
- Disinfection frequency: Fiber optic tube does not require disassembly and can be sterilized for over 4000 cycles.
- Required battery model: Uses standard C and AA batteries for certain configurations.
Product Models / Specification (summary)Basic Dimensions of handle (Unit: mm):
BMY-X01L — Long, thick handle version with fiber-optic illumination — D: 28.5 — H: 150
BMY-X01S — Short, thick handle version with fiber-optic illumination — D: 28.5 — H: 110
BMY-X02L — Long, thin handle version with fiber-optic illumination — D: 18 — H: 150
BMY-X02S — Short, thin handle version with fiber-optic illumination — D: 18 — H: 110
Size of Blade Unit (Unit: mm) — Model — Length/Specifications — Typical use — L(±10%) — B — H(±10%):
X-A50 — 50 — Premature baby — L:50 — B:9.0±1.5 — H:14
X-A65 — 65 — Newborn — L:65 — B:9.0±1.0 — H:14
X-A75 — 75 — Baby — L:75 — B:9.0±1.0 — H:15
X-A90 — 90 — Child — L:90 — B:9.0±1.0 — H:25
X-A105 — 105 — Adult trumpet — L:105 — B:10.0±1.0 — H:28
X-A130 — 130 — Adult medium — L:130 — B:16.0±2.0 — H:38
X-A155 — 155 — Adult large size — L:155 — B:16.0±2.0 — H:45
X-A180 — 180 — Adult extra large — L:180 — B:16.0±2.0 — H:50
X-B50 — 50 — Premature baby — L:50 — B:9.0±1.5 — H:15
X-B65 — 65 — Newborn — L:65 — B:11.0±1.0 — H:15
X-B75 — 75 — Baby — L:75 — B:11.0±1.0 — H:15
X-B85 — 85 — Child — L:85 — B:11.0±1.0 — H:15
X-B105 — 105 — Adult trumpet — L:105 — B:11.0±1.0 — H:15
X-B160 — 160 — Adult medium — L:160 — B:13.5±2.0 — H:16
X-B200 — 200 — Adult large size — L:200 — B:13.5±2.0 — H:17
X-B210 — 210 — Adult extra large — L:210 — B:13.5±2.0 — H:18
X-C105 — 105 — Adult trumpet — L:105 — B:14.0±1.5 — H:33
X-C135 — 135 — Adult medium — L:135 — B:16.0±1.5 — H:46
X-C155 — 155 — Adult large size — L:155 — B:60 — H:60
Laryngoscope Illumination UnitBlade appearance / Blade Length / Typical use / Fiber Guide Beam Lighting Type: Multiple blade models from 50 mm up to 210 mm are supported; illumination (fiber guide beam lighting) ≥ 500 lux for the blade types listed above.
Working ConditionsTemperature: 10°C - 40°C
Humidity: 30% - 75% RH
Atmospheric pressure: 860 hPa - 1060 hPa
Internal battery voltage: DC 2.7 V - DC 3.15 V
Hot tagsLaryngoscope; Fiber Optic Laryngoscope; Laryngoscope Handles; Fiberoptic Endoscopic Evaluation Of Swallowing Equipment; Laryngoscopy Direct With Biopsy; Endoscopy Anesthesia; Emergency Endoscopy
Technical specifications- Product name: Anesthesia Laryngoscope (reusable)
- Structure: blade + handle
- Lighting: LED bulb with fiber guide beam (fiber optic illumination)
- Battery types: standard C and AA batteries (for certain configurations)
- Disinfection: fiber optic tube sterilizable >4000 cycles without disassembly
- Handle model examples: BMY-X01L, BMY-X01S, BMY-X02L, BMY-X02S (D and H dimensions detailed above)
- Blade model examples and dimensions: X-A50 to X-A180, X-B50 to X-B210, X-C105/X-C135/X-C155 (lengths, B and H values detailed above)
- Illumination: ≥500 lux (fiber guide beam lighting type)
- Operating environment: 10℃-40℃, 30%-75% humidity, 860-1060 hPa
- Internal battery voltage range: DC2.7V - DC3.15V