Rigid laryngoscope BMY-X01L
with bladeautoclavable

Rigid laryngoscope - BMY-X01L - Jiangsu Unicron Medical Technology Co., Ltd - with blade / autoclavable
Rigid laryngoscope - BMY-X01L - Jiangsu Unicron Medical Technology Co., Ltd - with blade / autoclavable
Rigid laryngoscope - BMY-X01L - Jiangsu Unicron Medical Technology Co., Ltd - with blade / autoclavable - image - 2
Rigid laryngoscope - BMY-X01L - Jiangsu Unicron Medical Technology Co., Ltd - with blade / autoclavable - image - 3
Rigid laryngoscope - BMY-X01L - Jiangsu Unicron Medical Technology Co., Ltd - with blade / autoclavable - image - 4
Rigid laryngoscope - BMY-X01L - Jiangsu Unicron Medical Technology Co., Ltd - with blade / autoclavable - image - 5
Add to favorites
Compare this product

Characteristics

Shape
rigid
Options
with blade, autoclavable
Working length

50 mm, 65 mm, 75 mm, 85 mm, 90 mm, 105 mm, 130 mm, 135 mm, 155 mm, 160 mm, 180 mm, 200 mm, 210 mm
(2 in, 2.6 in, 3 in, 3.3 in, 3.5 in, 4.1 in, 5.1 in, 5.3 in, 6.1 in, 6.3 in, 7.1 in, 7.9 in, 8.3 in)

Total diameter (mm)

18 mm, 28.5 mm
(0.7 in, 1.1 in)

Description

Product Description
Product Name: Anesthesia Laryngoscope

Main structural Components
The anesthesia laryngoscope consists of a blade and handle. It features an LED light source with fiber-guide beam illumination. The product is reusable.

Applicable scope and applicable people
Scope of application: Used to assist tracheal intubation during clinical anesthesia or emergency care.
User group: Intended for clinicians performing tracheal intubation in anesthesia and emergency settings.

Representative product — Fiber Optic Model
  • Conduction principle: Light is conducted via fiber optic light guide as a cold light source.
  • Position of the bulb: LED bulb located at the front of the handle for prolonged use.
  • Disinfection frequency: Fiber optic tube does not require disassembly and can be sterilized for over 4000 cycles.
  • Required battery model: Uses standard C and AA batteries for certain configurations.


Product Models / Specification (summary)
Basic Dimensions of handle (Unit: mm):
BMY-X01L — Long, thick handle version with fiber-optic illumination — D: 28.5 — H: 150
BMY-X01S — Short, thick handle version with fiber-optic illumination — D: 28.5 — H: 110
BMY-X02L — Long, thin handle version with fiber-optic illumination — D: 18 — H: 150
BMY-X02S — Short, thin handle version with fiber-optic illumination — D: 18 — H: 110

Size of Blade Unit (Unit: mm) — Model — Length/Specifications — Typical use — L(±10%) — B — H(±10%):
X-A50 — 50 — Premature baby — L:50 — B:9.0±1.5 — H:14
X-A65 — 65 — Newborn — L:65 — B:9.0±1.0 — H:14
X-A75 — 75 — Baby — L:75 — B:9.0±1.0 — H:15
X-A90 — 90 — Child — L:90 — B:9.0±1.0 — H:25
X-A105 — 105 — Adult trumpet — L:105 — B:10.0±1.0 — H:28
X-A130 — 130 — Adult medium — L:130 — B:16.0±2.0 — H:38
X-A155 — 155 — Adult large size — L:155 — B:16.0±2.0 — H:45
X-A180 — 180 — Adult extra large — L:180 — B:16.0±2.0 — H:50
X-B50 — 50 — Premature baby — L:50 — B:9.0±1.5 — H:15
X-B65 — 65 — Newborn — L:65 — B:11.0±1.0 — H:15
X-B75 — 75 — Baby — L:75 — B:11.0±1.0 — H:15
X-B85 — 85 — Child — L:85 — B:11.0±1.0 — H:15
X-B105 — 105 — Adult trumpet — L:105 — B:11.0±1.0 — H:15
X-B160 — 160 — Adult medium — L:160 — B:13.5±2.0 — H:16
X-B200 — 200 — Adult large size — L:200 — B:13.5±2.0 — H:17
X-B210 — 210 — Adult extra large — L:210 — B:13.5±2.0 — H:18
X-C105 — 105 — Adult trumpet — L:105 — B:14.0±1.5 — H:33
X-C135 — 135 — Adult medium — L:135 — B:16.0±1.5 — H:46
X-C155 — 155 — Adult large size — L:155 — B:60 — H:60

Laryngoscope Illumination Unit
Blade appearance / Blade Length / Typical use / Fiber Guide Beam Lighting Type: Multiple blade models from 50 mm up to 210 mm are supported; illumination (fiber guide beam lighting) ≥ 500 lux for the blade types listed above.

Working Conditions
Temperature: 10°C - 40°C
Humidity: 30% - 75% RH
Atmospheric pressure: 860 hPa - 1060 hPa
Internal battery voltage: DC 2.7 V - DC 3.15 V

Hot tags
Laryngoscope; Fiber Optic Laryngoscope; Laryngoscope Handles; Fiberoptic Endoscopic Evaluation Of Swallowing Equipment; Laryngoscopy Direct With Biopsy; Endoscopy Anesthesia; Emergency Endoscopy

Technical specifications
  • Product name: Anesthesia Laryngoscope (reusable)
  • Structure: blade + handle
  • Lighting: LED bulb with fiber guide beam (fiber optic illumination)
  • Battery types: standard C and AA batteries (for certain configurations)
  • Disinfection: fiber optic tube sterilizable >4000 cycles without disassembly
  • Handle model examples: BMY-X01L, BMY-X01S, BMY-X02L, BMY-X02S (D and H dimensions detailed above)
  • Blade model examples and dimensions: X-A50 to X-A180, X-B50 to X-B210, X-C105/X-C135/X-C155 (lengths, B and H values detailed above)
  • Illumination: ≥500 lux (fiber guide beam lighting type)
  • Operating environment: 10℃-40℃, 30%-75% humidity, 860-1060 hPa
  • Internal battery voltage range: DC2.7V - DC3.15V