Magnetic transcranial magnetic stimulator YK-7000E
TMS + rTMSfor treatment of neurasthenia

Magnetic transcranial magnetic stimulator - YK-7000E - Jiangsu Yikang Electronic Technology - TMS + rTMS / for treatment of neurasthenia
Magnetic transcranial magnetic stimulator - YK-7000E - Jiangsu Yikang Electronic Technology - TMS + rTMS / for treatment of neurasthenia
Magnetic transcranial magnetic stimulator - YK-7000E - Jiangsu Yikang Electronic Technology - TMS + rTMS / for treatment of neurasthenia - image - 2
Magnetic transcranial magnetic stimulator - YK-7000E - Jiangsu Yikang Electronic Technology - TMS + rTMS / for treatment of neurasthenia - image - 3
Magnetic transcranial magnetic stimulator - YK-7000E - Jiangsu Yikang Electronic Technology - TMS + rTMS / for treatment of neurasthenia - image - 4
Magnetic transcranial magnetic stimulator - YK-7000E - Jiangsu Yikang Electronic Technology - TMS + rTMS / for treatment of neurasthenia - image - 5
Add to favorites
Compare this product

Characteristics

Type of stimulation
magnetic, TMS + rTMS
Application
for treatment of neurasthenia

Description

The YK-7000E is a dual-channel, trolley-type transcranial magnetic stimulation (TMS) therapy device designed for repetitive transcranial magnetic stimulation (rTMS) to construct a three-dimensional magnetic therapy network that stimulates the central nervous system and assists nervous system rehabilitation.

Product overview
The device applies rTMS to regulate brain function via non-invasive magnetic stimulation and integrates complementary non-invasive technologies to enhance therapeutic effects.

Core technology features
  • (I) TMS technology features
    • Non-invasive design: no surgery or puncture required.
    • Precise targeting: can be applied to specific areas of the cerebral cortex.
    • Gentle physical effect: controllable action process suitable for long-term clinical applications.
  • (II) Simulated Bioelectric Postauricular Electrical Stimulation technology
    • Convenient postauricular targeting: electrodes attach behind the ear to precisely target the cerebellar parietal nucleus.
    • Bioelectric simulation adaptation: simulates physiological electrical signals for strong compatibility and reduced stress response in nerve tissue.
    • Adjustable parameters: supports personalized adjustment of stimulation intensity, frequency and other parameters.
  • (III) Magnetic Therapy Cap technology
    • Distributed target coverage: cap integrates multiple magnetic therapy units for multi-target stimulation.
    • Flexible and comfortable ergonomic design; adjustable size to suit different head shapes.
    • Controllable magnetic field parameters: precise adjustment of magnetic field strength and duration.
    • Safe: no side effects reported in the product description.


Scope of application
Suitable as an adjunct treatment for ischemic cerebrovascular disease, neurasthenia and brain injury.

Characteristics
  • Entire process non-invasive: no intracranial intervention required.
  • Precise coverage of multiple targets, individually or synergistically.
  • Personalized adaptation and adjustment to improve treatment outcomes.
  • Safe, compatible, and without side effects; reduces neural tissue stress response.
  • Synergistic effect combining electromagnetic field, bioelectricity and multi-frequency micro-vibration.
  • Three complementary non-invasive technologies working together.
  • Long-lasting and precise dual protection; safe, gentle and easily tolerated.
  • Portable trolley design for easy movement.
  • Multiple language options and CE/ISO certification noted.


Configuration
  • EK-7000J / YK-7000E trolley main unit
  • Smart touch screen
  • Dual-channel design (allows simultaneous treatment of two patients/channels)
  • Smart treatment cap — multiple models available; high-end integrated cap ergonomically designed and adjustable for different head shapes


Technical specifications
  • Dual ultra-clear, low-power, wide-view LCD display with dual-channel output (simultaneous dual-channel operation).
  • Treatment time adjustable from 0 to 99 minutes (step 1 minute); default start-up time 20 minutes; countdown timer with alarm.
  • Magnetic therapy intensity: strong 10 mT–17 mT; weak 3 mT–9 mT.
  • Magnetic field frequency: 50 Hz ±12%.
  • Vibration intensity settings: off / weak / medium / strong corresponding to peak driving voltages 0 V / 10 V / 16 V / 27 V.
  • Vibration frequency settings: off / weak / medium / strong corresponding to 0 Hz / 2 Hz / 5 Hz / 10 Hz.
  • Deluxe ABS universal trolley for mobility.
  • High-end integrated aviation treatment cap, ergonomically designed, comfortable to wear and size-adjustable.

Other Jiangsu Yikang Electronic Technology products

Transcranial magnetic stimulators

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.