OverviewLabotemp PCR Machine LPC-01 is a compact PCR thermocycler for reliable DNA amplification in clinical diagnostics, molecular biology and research laboratories. It accepts 96 × 0.1/0.2 ml PCR tubes or a 96-well PCR plate, offers a module temperature range of 4–105 °C and a maximum heating/cooling ramp rate of 5.5 °C/s to accelerate run times while maintaining reproducibility.
Key Capabilities- Peltier (semiconductor) temperature control for rapid and even temperature changes
- Built-in gradient function (30–105 °C) to optimize assay conditions across samples
- 7-inch color touchscreen for programming, monitoring and quick protocol selection
- Storage for up to 700 programs and support for up to 100 cycles
- Automatic fault detection and power-off protection for data and run security
Why Choose Labotemp PCR Machine LPC-01- Flexible sample formats: 96 × 0.1/0.2 ml tubes or 96-well plate compatibility for standard laboratory workflows
- Gradient capability: enables rapid optimization of annealing temperatures across a plate
- Fast temperature ramping and high uniformity: reduces experiment time while ensuring consistent results across wells
- Large program memory and intuitive touchscreen: streamlines protocol setup and repeatability
Features- Fast thermal cycling with a maximum ramp rate of 5.5 °C/s
- Temperature display accuracy ±0.1 °C; control accuracy ±0.3 °C
- Temperature uniformity ±0.3 °C @ 55 °C across the 96-well block
- Gradient range 30–105 °C (span 1–42 °C)
- 7-inch color touch screen and user-friendly interface
- Program storage up to 700 protocols; up to 100 cycles
- Compact footprint: dimensions 270 × 240 × 150 mm; net weight 4.8 kg
- Safety: automatic fault detection, alarm system and power-off protection
Applications- Molecular biology and gene amplification (PCR assays, cloning prep)
- Clinical and diagnostic testing (pathogen detection, genetic tests)
- Genomics workflows (gene expression studies, sequencing sample prep)
- Forensic analysis and agricultural genetics (DNA identification, plant genetics)
Specification Table- Reaction volume: 1–100 µl
- Module temperature range: 4–105 °C
- Hot lid temperature range: 30–110 °C
- Temperature display accuracy: ±0.1 °C
- Temperature control accuracy: ±0.3 °C
- Temperature uniformity: ±0.3 °C @ 55 °C
- Maximum heating/cooling rate: 5.5 °C/s
- Gradient temperature range: 30–105 °C (span: 1–42 °C)
- Power supply: 100–240 V, 50/60 Hz
- Sample capacity: 96 × 0.1/0.2 ml tubes or 96-well PCR plate
- Program storage: up to 700 programs
- Maximum number of cycles: 100
- Power-off protection: Yes
- Net weight: 4.8 kg; Gross weight: 5.2 kg
- Dimensions (L × W × H): 270 × 240 × 150 mm