Interlocking Intramedullary Nail SystemOverviewThe modular intramedullary nail system is indicated for fixation of proximal humeral, proximal femoral, femoral shaft and tibial fractures. The portfolio includes PFNA, femoral reconstruction (standard and long gamma) nails and tibial interlocking nails with matching locking bolts, blades, lag screws and end caps. Components are mainly titanium alloy; selected femoral nails are available in stainless steel.
Humeral Interlocking Nail- Proximal multiloc screws (4.5 mm, gold): flat-head design reduces risk of screw penetration.
- Four suture holes in the tail enable secure rotator cuff attachment.
- Countersunk screw options minimize implant prominence.
- Use of 3.5 mm (green) locking self-tapping screws (screw-in-screw) can enhance fixation stability.
Multidimensional Fixation of Proximal Humeral Interlocking ScrewThe proximal locking hole maintains angular stability and reduces screw back-out; multi-plane interlocking options limit implant toggling.
Humeral Interlocking Screw (4.0 mm) — Ascending ScrewSelection of an ascending screw provides medial calcar support for proximal humeral fractures.
Proximal Femoral Nail Anti-rotation (PFNA)Application: Used in a variety of proximal femoral fractures including:
- Sub-trochanteric fractures
- Inter-trochanteric fractures
Diameter: Φ9.5–Φ12.0
Length: 170 mm; 200 mm; 240 mm; 320 mm; 340 mm; 360 mm; 380 mm; 400 mm; 420 mm; 440 mm
Material: Titanium Alloy
Matching Locking Bolt: Φ4.8×25 mm – Φ4.8×85 mm
PFNA Blade: Φ10.4×75 mm – Φ10.4×120 mm
End Cap Spec: M10*(16,21,40)
End Cap Material: Titanium Alloy
Femoral Reconstruction Interlocking Nail (II)Application: Used in femoral fractures including:
- Sub-trochanteric fractures
- Inter-trochanteric fractures
- Nonunions
- Femoral shaft fractures
Diameter: Φ9.5–Φ12.0
Length: 320 mm–440 mm
Material: Titanium Alloy
Femoral Reconstruction Interlocking Nail (Standard Gamma Nail)Application: Used in proximal femoral fractures including:
- Sub-trochanteric fractures
- Inter-trochanteric fractures
- Nonunions
Diameter: Φ9.0; Φ10.0; Φ11.0
Length: 220 mm; 240 mm; 260 mm
Material: Titanium Alloy; Stainless Steel
Matching Locking Bolt: Φ4.8×30 mm – Φ4.8×85 mm
Matching Lag Screw: Φ6.0×65 mm – Φ6.0×115 mm
Femoral Reconstruction Interlocking Nail (Long Gamma Nail)Application: Used in proximal and shaft femoral fractures including:
- Sub-trochanteric fractures
- Inter-trochanteric fractures
- Nonunions
- Femoral shaft fractures
Diameter: Φ9.0; Φ10.0; Φ11.0
Length: 300 mm–420 mm
Material: Titanium Alloy; Stainless Steel
Tibial Interlocking Nail (II)Application: Indicated for tibial fractures
Diameter: Φ8.5–Φ10.0
Length: 255 mm–375 mm
Material: Titanium Alloy
End Cap Spec: M8*(12–27)
Matching Locking Bolt Spec: Φ4.4×25 mm – Φ4.4×80 mm; Φ4.8×25 mm – Φ4.8×90 mm
Technical specifications- Materials: Titanium Alloy (majority of components); Stainless Steel available for select femoral nails.
- PFNA diameters: Φ9.5–Φ12.0; PFNA lengths: 170–440 mm.
- PFNA matching locking bolt range: Φ4.8×25–Φ4.8×85 mm; PFNA blade sizes: Φ10.4×75–Φ10.4×120 mm.
- Femoral Reconstruction Nail diameters: Φ9.5–Φ12.0; lengths: 320–440 mm.
- Standard Gamma Nail diameters: Φ9.0, Φ10.0, Φ11.0; lengths: 220 mm, 240 mm, 260 mm; matching lag screw Φ6.0×65–Φ6.0×115 mm.
- Long Gamma Nail lengths: 300–420 mm.
- Tibial Interlocking Nail diameters: Φ8.5–Φ10.0; lengths: 255–375 mm; matching locking bolts Φ4.4×25–Φ4.4×80 mm and Φ4.8×25–Φ4.8×90 mm.
- End cap specifications: PFNA M10*(16,21,40); Tibial M8*(12–27).