Spec. - A(mm) - B(mm) - C(mm) - D(mm) - F(mm) 1# - 51 - 35.4 - 27.2 - 7 - 130 2# - 54 - 37.7 - 28.5 - 8 - 140 3# - 54 - ...
Femoral stem length: 120, 130, 140, 150, 190 mm
Size Length(mm) Femoral Canal Reamer Femoral canal Broach Centralizer Restrictor 0 - 120 - 1(7.5) - 1 - 0 - >Ф11 1 - 130 - 2.5(9.75) ...
Excia® Hip Stem System Less invasive. Modern hip replacement. Excia® straight stems are designed for implant longevity with or without bone cement – with standard or high offset – suitable for all ...
Aesculap®
TrendHip® Hip Stem System Traditional hip replacement The TrendHip® design concept combines the traditional features of a straight tapered and fully surface coated cementless hip stem. The implant ...
Aesculap®
TRJ® Hip Stem Trochanter retaining joint replacement The TRJ® hip prosthesis stem is implanted withoutcement. The stem design is based on many years of experience with a conical ...
Aesculap®
CCD angle: 135, 127 °
... SMS femoral stem has been designed to meet today’s THA challenges in a growing patient population . The stem is designed to achieve a more physiological proximal load transfer and ...
Medacta
CCD angle: 130, 125 °
... PARADOX" A stem matching the femoral canal is implanted line-to-line, resulting in a thin cement mantle. The French technique is intended to maximize the stem size within the medullary ...
Medacta
Femoral stem offset: 35.5, 37.5, 44, 50 mm
CCD angle: 125 °
... mm shortened X-acta stem was designed to facilitate stem implantation through the AMIS approach and reduce bone removal. SUCCESSFUL CLINICAL HISTORY The collarless, double-tapered, polished design ...
Medacta
Femoral stem length: 120, 300 mm
CCD angle: 127.3, 130 °
... remains faithful to the original concept: INITIALE®: cemented primary femoral stem that is also available in a dysplasia version. INITIALE® Revision: cemented revision femoral stem ...
Amplitude Surgical
Femoral stem length: 171, 91 mm
... available. Extra-medullary part evolves with stem’s size: Lateralization and CCD angle are larger on larger sizes. High Offset option collarless — 8 sizes available. Collar starting in the internal axis of the stem: ...
Amplitude Surgical
Femoral stem length: 98, 134 mm
CCD angle: 137, 129 °
... Standard stem corresponds to a modular ACOR® stem with A/R neck and regular anteversion/retroversion values. The joint centre of the Lateralised stem corresponds to a modular ACOR® stem ...
Amplitude Surgical
Femoral stem length: 130, 162 mm
CCD angle: 135 °
The non-cemented stems are made of a titanium alloy. They are coated with TPS (Titanium Plasma Spray) and BONIT® in the proximal area of the hip stem. The cemented versions of the hip stems ...
Femoral stem length: 129, 191 mm
CCD angle: 123, 131 °
... non-cemented stem is based on the principles of biological cortical anchorage, as described by Prof. Dr. K. Zweymüller. This stem design has been in clinical use for more than 30 years. With its conical ...
CCD angle: 126, 135 °
• The range of stems allows the implant to be matched to all bone sizes. • All cementless implants are coated with a titanium plasma+HA coating. • Taper 12/14, completely conical form.
CCD angle: 135, 126 °
• The range of stems allows the implant to be matched to all bone sizes. • Taper 12/14, completely conical form.
Femoral stem length: 7.5, 13.5 mm
Acetabular cup diameter: 22 mm - 28 mm
Femoral head diameter: 42 mm - 62 mm
Femoral Stem Dual Coated (Cementless) used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Bipolar Head Acetabular ...
Zimed Medical
Acetabular cup diameter: 25 mm - 55 mm
Femoral head diameter: 9 mm - 13 mm
HIP JOINT PROSTHESES Calcar Replacement Sandblasting Stem (Cemented) femoral calcar stem, hip replacement; -Range 25-55mm -Diameter:9-13mm -Sandblasting stem -Stainless ...
Zimed Medical
Femoral stem length: 55, 25 mm
Femoral stem offset: 17, 9 mm
Acetabular cup diameter: 42 mm - 62 mm
Calcar Replacement Stem Dual Coated (Cementless) used together products Femoral Head Modular Ø 28 Mm 12/14 Mm Femoral Head Modular Ø 22 Mm 12/14 Mm Bipolar Head Acetabular Screw Acetabular ...
Zimed Medical
CCD angle: 135, 125 °
The EUROSTEM implant is a quadrangular femoral stem with trapezoidal proximal section and a conical distal section inspired by the CORAIL® philosophy and dedicated to hip arthroplasty. The EUROSTEM ...
CCD angle: 135 °
• TA6V ELI + HAP coating for the cementless version and INOC M30NW for the cemented version. • Proximal flaring ensuring tri-axial metaphyseal locking. • Anti rotating longitudinal grooves. • Gripping holes to ease implant positioning. • ...
... replacement in skeletally mature individuals. The system consists of monolithic cemented and press-fit femoral stems, modular CoCr and BIOLOX® delta femoral heads in various sizes ...
... replacement in skeletally mature individuals. The system consists of monolithic cemented and press-fit femoral stems, modular CoCr and BIOLOX® delta femoral heads in various sizes ...
... replacement in skeletally mature individuals. The system consists of monolithic cemented and press-fit femoral stems, modular CoCr and BIOLOX® delta femoral heads in various sizes ...
Femoral stem length: 200, 250 mm
... intended to improve range of motion and reduce impingement risk. Stems grow proportionally in both neck and overall length to provide greater offset and head height for larger patients. Offset+ stems ...
... native physiological bone strain to enhance the quality of stem fixation. The Paragon Stem length is shorter than some of the other bi-planar wedge designs currently on the market. The stem ...
Femoral stem length: 100 mm
... properties. A Morse taper connection provides intra-component strength and stability3 to the taper junction, essential to long term stem performance. A Ti6Al4V locking screw then fixes the proximal component position. Stabilise Longitudinal ...
Femoral stem length: 137, 177 mm
Femoral stem offset: 37.4, 46.9 mm
CCD angle: 132 °
... Proximally tapered stem geometry converts the shear forces to compressive load. • This helps the stem to resist subsidence and medial migration. Extensive Stress Distribution • Low elastic modulus ...
Corentec
• Femoral Component is a typical double-tapered wedge stem, designed to suit the anatomical structure in the marrow cavity. • The section is rectangular-shaped, allowing a strong initial press-fit fixation ...
Corentec
Femoral stem length: 190, 150 mm
Femoral stem offset: 40 mm
CCD angle: 135 °
· Low Height 50mm enables the proximal body to avoid the impingement with the inner corical bone · Although Corentec has the thicker body than others. this option can solve the problem Proxiaml Body : Neck Shape · Patented trapezoidal ...
Corentec
CCD angle: 135 °
... wear resistance: cementes stem is made of REX steel, cementless is of titanium. Cementless mircoporotic surface can be titanium plasma or Hydroxi-apatite as well. With the wide range of stems, resps functioning ...
Sanatmetal
Mirror polished classical Exeter shape with slide & block philosophy which has already proven its advantages during multimillion insertions worldwide
Sanatmetal
Femoral stem length: 3, 10 mm
Heads connect through 12/14 Eurocone to the stems, sizes are in 28 mm and large ones are also available. Raw material is CoCr or ceramics
Sanatmetal
CCD angle: 135, 125 °
The progressive trapezoidal geometry enables optimal adaptation of the stem and both anti-translational and anti-rotational fixation that provides perfect primary stability while preventing the hip prosthesis from sinking. Specifications Standard ...
Surgival
CCD angle: 135 °
Made from High Nitrogen Stainless Steel (ISO 5832- 9). Triple wedge design: The trapezoidal shape in the sagittal and frontal planes offers enhanced primary stability and prevents prosthesis sinking. Polished surface with rounded ...
Surgival
Femoral stem length: 175, 250 mm
CCD angle: 135 °
... preventing rotation, reducing distal rigidity with respect to the metaphyseal portion and improve diaphyseal vascularisation of the femur with the prosthetic. Distal opening that reduces implant rigidity and improves ...
Surgival
Femoral stem length: 250, 150, 190, 200 mm
... Intraoperative Flexibility With three proximal bodies and five distal stems, which all work together regardless of size, a surgeon is able to address deficiencies in both regions of the femur independent ...
Zimmer Biomet
CCD angle: 126, 135 °
... for excellent proximal stability. The shortened stem length and narrow distal top allows for ease of implantation. The POLARSTEM can be used for all standard femoral morphologies. The range of stems ...
... ceramic heads, C-STEM™ AMT is a flexible stem solution for total and hemi-hip replacement procedures. (Please refer to the IFU for indications) The system options available include: Standard offset ...
Depuy Synthes
... rectangular form of the CLP® hip stem assures rotational stability by providing a mechanical interlock with the proximal femoral cortical bone. Unique Contour The unique contour that conforms to the ...
Djo Surgical
Femoral Hip Stem Morphometric wedge femoral stem, an evolution of your conventional tapered wedge stem that is SOMA-designed for today’s diverse THA ...
Stryker
Femoral stem length: 250, 300, 135, 165, 200 mm
Femoral head diameter: 28 mm - 36 mm
... customization to address a wide range of proximal bone-loss situations Flexible Independent neck version and stem placement minimize the potential of femoral fracture and post-operative discloation3
Exactech
Femoral stem length: 95, 145 mm
Femoral stem offset: 38.5 mm
CCD angle: 135 °
TBG Cementless Hip Stem System
Double Medical Technology
Femoral stem length: 130, 150, 170 mm
Femoral stem offset: 35, 40, 37, 49, 46 mm
CCD angle: 117, 135, 126 °
... anatomical shape of the femur Successfully used for 40 years Proven by a wealth of clinical data. Minimal occurrence of periprosthetic fractures Minimally invasive implantation Neutralizes torsional forces: The ...
Waldemar Link
... Features and Benefits Historically Influential The most referenced stem design with over 25 years of clinical use. Standard Length Stem Designed for rotational stability within the femoral ...
CCD angle: 125, 135 °
... Uncemented femoral stem has both vertical and horizontal grooves to provide rotational and axial stability. 4. Uncemented femoral stem neck has standard 12/14 taper ...
CCD angle: 135, 127 °
... hip stems has an established clinical history. Each Profemur® hip stem offers its own philosophy to provide fixation and replace bone anatomy. Tapered wedge stem philosophy Designed ...
Femoral stem length: 95, 135 mm
Femoral stem offset: 32, 53 mm
The UTF (United Tapered Fit) Reduced Stem Primary Hip System offers a dual taper wedge stem design. This taper-fit concept is intended to engage the cortex in the stem corners to provide ...
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining