Radiography X-ray generator NexGen 900
equipment-mountedwith power supply

Radiography X-ray generator - NexGen 900  - Medicatech USA - equipment-mounted / with power supply
Radiography X-ray generator - NexGen 900  - Medicatech USA - equipment-mounted / with power supply
Add to favorites
Compare this product

Characteristics

Type of imagery
for radiography
Ergonomic design
equipment-mounted
Options
with power supply
Output power

40 kW, 50 kW
(54.4 hp, 68 hp)

Description

Overview
The NEXGEN 900 series are high-frequency X-ray generators for clinical radiography. Available in 40 kW (NEXGEN-940, NEXGEN-940pa) and 50 kW (NEXGEN-950), they support fast exposure cycles, compact integration and digital imaging workflows.

Key features
  • High-frequency output for improved image clarity and dose control
  • Consistent 40 kW and 50 kW performance across models
  • Power Assist option (NEXGEN-940pa)
  • Fast exposure and recharge times with minimal warm-up
  • Accurate dose control and optimized tube protection
  • Compact design suitable for integration into DR/CR and mobile systems
  • Reduced maintenance requirements for high-volume environments


Technical specifications
  • Models: NEXGEN-940 (40 kW); NEXGEN-940pa (40 kW, Power Assistance); NEXGEN-950 (50 kW)
  • Output rating: 40 kW (NEXGEN-940 / 940pa), 50 kW (NEXGEN-950)
  • Input power: 230 VAC ±10%, 50/60 Hz, single-phase (NEXGEN-940); 120 VAC ±10%, 50/60 Hz (NEXGEN-940pa); 230 VAC ±10%, 50/60 Hz, three-phase (NEXGEN-950)
  • kV range: 40–125 kV (940 / 940pa); 40–150 kV (950) with 1 kV steps
  • mA range: 10–500 mA (940 / 940pa); 10–630 mA (950)
  • Exposure time range: 0.001–10 s
  • Rotor supply: low speed standard; optional dual speed starter (NEXGEN-950)
  • Maximum outputs: 500 mA @ 80 kV; 400 mA @ 100 kV; 320 mA @ 125 kV (940/940pa); 630 mA @ 80 kV; 500 mA @ 100 kV; 320 mA @ 150 kV (950)
  • Reproducibility: coefficient of variation kV < 0.005; Time < 0.005; mAs < 0.01
  • Accuracy: kV ±(3%+1 kV); mA ±(5%+1 mA); Time ±(1%+1 ms); mAs ±(5%+1 mAs)
  • Linearity: coefficient of linearity < 0.01 (CL = (X1-X2)/(X1+X2), X = mR/mAs)


Applications
  • General radiography for hospitals and imaging centers
  • Integration with digital radiography (DR) and computed radiography (CR) systems
  • High-throughput and mobile imaging suites


Compliance & maintenance
  • Designed to meet clinical accuracy and reproducibility requirements listed above
  • Optimized tube protection features and reduced routine maintenance intervals
  • Support for digital workflows and standard safety practices


Options & ordering
  • Power Assist model: NEXGEN-940pa
  • Optional dual speed starter available for NEXGEN-950
  • Contact manufacturer or distributor for integration, configuration and support

Catalogs

No catalogs are available for this product.

See all of Medicatech USA‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

RSNA 2026
RSNA 2026

29 Nov - 03 Dec 2026 Chicago (USA - Illinois) Hall A - Stand 2601

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.