Analog or digital intraoral X-ray system
wall-mountedon casters70 kV

Analog or digital intraoral X-ray system - Medicatech USA - wall-mounted / on casters / 70 kV
Analog or digital intraoral X-ray system - Medicatech USA - wall-mounted / on casters / 70 kV
Analog or digital intraoral X-ray system - Medicatech USA - wall-mounted / on casters / 70 kV - image - 2
Add to favorites
Compare this product

Characteristics

Technology
analog or digital
Ergonomics
on casters, wall-mounted
Tube voltage (kV)
70 kV, 60 kV, 65 kV

Description

Overview
  • Portable and wall-mountable dental X-ray generator for intraoral imaging with selectable high-voltage outputs and fixed anodic current.
  • Suitable for clinics requiring flexible installation and reliable exposure control.


Key features
  • Dual installation modes: mobile unit or wall-mount to adapt to different clinical workflows.
  • Selectable high voltage: 60 / 65 / 70 kV; anodic current: 5 mA.
  • Wide input range 110–240 V ±10% and 50/60 Hz compatibility for international use.
  • Exposure time range 0.01–2.0 s (R’10 scale) with accuracy ±10% + 1 ms; maximum load 70 kV, 5 mA, 2 s.


Technical specifications
  • Nominal voltage: 110~240 V ± 10%
  • Line frequency: 50/60 Hz
  • Absorbed current: 2.1 A @ 240V~; 5.2 A @ 110V~
  • Absorbed power: 500 VA @ 240V~; 530 VA @ 110V~
  • Maximum apparent line resistance: ≤0.8 Ohm @ 240V~; ≤0.4 Ohm @ 110V~
  • Fuse of the distribution panel F1: ETF-6.3 A / 250V UL/CSA
  • Main fuse (mobile unit) F2: F 6.3 A / 250 V 6.3×32 mm UL/CSA
  • High voltage values (kV): 60 / 65 / 70 kV selectable
  • High voltage accuracy (kV): ± 10%
  • Anodic current (mA): 5 mA
  • Anodic current accuracy (mA): ± 20%
  • Exposure time (s): 0.01 – 2.0 s according to R’10 scale
  • Exposure time accuracy (s): ± 10% +1 ms
  • Maximum load: 70 kV 5 mA 2 s
  • Operation type: Momentary: 2 sec. max


Compliance and safety
  • Fuse and resistance specifications included for safe integration into clinical electrical systems.
  • Designed for dental radiography; installation must follow local regulations and radiation safety guidelines.


Ordering information
  • Specify required configuration when ordering: mobile unit (cart) or wall-mount unit.
  • Contact authorised distributor for options, accessories and installation service.

Catalogs

No catalogs are available for this product.

See all of Medicatech USA‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

RSNA 2026
RSNA 2026

29 Nov - 03 Dec 2026 Chicago (USA - Illinois) Hall A - Stand 2601

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.