GOD blood glucose meter GlucoMen areo GK
electrochemicalfor hospitalsketonemia

GOD blood glucose meter - GlucoMen areo GK - Menarini Diagnostics - electrochemical / for hospitals / ketonemia
GOD blood glucose meter - GlucoMen areo GK - Menarini Diagnostics - electrochemical / for hospitals / ketonemia
GOD blood glucose meter - GlucoMen areo GK - Menarini Diagnostics - electrochemical / for hospitals / ketonemia - image - 2
GOD blood glucose meter - GlucoMen areo GK - Menarini Diagnostics - electrochemical / for hospitals / ketonemia - image - 3
GOD blood glucose meter - GlucoMen areo GK - Menarini Diagnostics - electrochemical / for hospitals / ketonemia - image - 4
Add to favorites
Compare this product

Characteristics

Technology
GOD, electrochemical
Applications
for hospitals
Other measured parameters
ketonemia, with blood ketone meter
Other characteristics
with USB, smartphone-based
Result display time

5 s, 8 s

Sample volume

Min.: 0.0005 ml
(0 US fl oz)

Max.: 0.0008 ml
(0 US fl oz)

Memory capacity

100 unit, 730 unit

Weight

46 g
(1.6 oz)

Length

107 mm
(4.2 in)

Width

58 mm
(2.3 in)

Height

13.5 mm
(0.5 in)

Description

Overview
  • Combined blood glucose and ketone self-monitoring system that performs glycaemia and ketonemia tests in a single meter suitable for people with diabetes.
  • Designed to prioritise measurement accuracy, hypoglycaemia detection and ease of use in clinical and home settings.


Key benefits
  • Analytical performance meeting and exceeding EN ISO 15197:2015 accuracy requirements.
  • High sensitivity under hypoglycaemic levels: validated performance for values below 60 mg/dL to support detection of hypoglycaemic episodes.
  • Stable, long-lasting operation with battery life suitable for prolonged monitoring.
  • Improved readability: integrated top display light for clear results in varied lighting conditions.
  • Compact, thin and lightweight pocket design facilitating portability.
  • Dual-strip concept: one meter supports both blood glucose test strips and ketone test strips.
  • User-oriented interface: large display and navigation buttons, strip ejector feature to reduce contamination risk.
  • Includes eco-friendly pouch made from recycled PET (PVC free) and compatible lancet/strip accessories (Glucoject solutions).
  • Connectivity options: NFC for smartphone data exchange (GlucoLog app), USB cable option and integration with GlucoLog web cloud for remote monitoring and data sharing with healthcare professionals and caregivers.


Multimedia and support
  • Product video available (embedded YouTube demonstration of device operation and features).
  • Video brochure and short clips presenting accuracy, hypoglycaemia detection and long-term performance.


Technical specifications
  • Product: GlucoMen areo GK
  • Manufacturer: A. Menarini Diagnostics S.r.l.
  • Tests: Glycaemia; ketonemia
  • Strip coding: Not required
  • Blood sample: whole fresh capillary
  • Temperature compensation: automatic via integrated thermal sensor
  • Batteries: 2 × 3.0 V lithium (CR2032)
  • Battery life: minimum 900 tests or approximately 1 year (2–3 tests/day)
  • Memory: 730 blood glucose results and 100 ketonemia results with markers, dates and times (cyclical overwrite)
  • Data management: pre/post-meal markers, physical activity and control data available
  • Alarms: up to six audible alarms (three for blood glucose, three for ketonemia)
  • Data transfer: dedicated USB cable or built-in NFC
  • Averages (blood glucose): 1, 7, 14, 30, 60, 90 days
  • Automatic shutdown: 90 s inactivity before test (strip inserted, flashing drop icon); 60 s after test or certain errors; 5 s after some error icons
  • Dimensions: 107 × 58 × 13.5 mm
  • Weight: 46 g (without batteries)
  • Operating conditions: blood glucose test 5–45 °C; ketonemia 10–40 °C; relative humidity ranges: blood glucose 20–90% non-condensing; ketone <85%
  • Storage (instrument): -20–50 °C; relative humidity 20–90%
  • Control solution storage: 4–30 °C
  • Operating environment: EMC compliant
  • EU Directive / Classification: 98/79/EC / Annex II, List B
  • Device standard: EN ISO 15197:2015
  • Blood glucose strips (GlucoMen areo Sensor): unit mg/dL or mmol/L; range 20–600 mg/dL (1.1–33.3 mmol/L); hematocrit range 10–70% (compensated); sample volume 0.5 µL; analysis duration 5 s; method: electrochemical glucose oxidase (GOD) with hexacyanoferrate(III) mediator; storage 4–30 °C, RH 20–90%; expiry unopened 24 months, 12 months after opening bottle
  • Ketone strips (GlucoMen areo ß-Ketone Sensor): unit mmol/L; range 0.1–8.0 mmol/L; hematocrit range 20–60% (compensated); sample volume 0.8 µL; analysis duration 8 s; method: electrochemical ß-hydroxybutyrate dehydrogenase with 1,10-phenanthroline-5,6-dione mediator; storage 4–30 °C; expiry: aluminium-blistered, valid 18 months from manufacture