Characteristics

Technology
GOD, with glucose oxidase, electrochemical
Other measured parameters
ketonemia, with blood ketone meter
Other characteristics
no coding, with USB port, with USB, smartphone-based
Result display time

5 s, 8 s

Sample volume

Min.: 0.0005 ml
(0 US fl oz)

Max.: 0.0008 ml
(0 US fl oz)

Memory capacity

100 unit, 730 unit

Weight

46 g
(1.6 oz)

Length

107 mm
(4.2 in)

Width

58 mm
(2.3 in)

Height

13.5 mm
(0.5 in)

Description

Product overview
  • Self-monitoring system for blood glucose and ketones intended for people with diabetes.
  • Designed for high analytical performance at low glucose values to support hypoglycaemia detection; accuracy compliant with EN ISO 15197:2015.
  • Compact, lightweight meter with built-in display light and non-slip feet for stable placement.


Key features
  • Dual-testing capability: measures blood glucose and ketonemia with the same meter.
  • High accuracy and long-lasting performance (EN ISO 15197:2015 compliant).
  • Built-in display light and large, easy-to-read digits for use in varied lighting conditions.
  • NFC connectivity for data sharing with smartphones; compatible with GlucoLog app and GlucoLog web cloud platform for remote monitoring and sharing with medical staff and caregivers.
  • Thin, pocket-size form factor with strip ejector to avoid contamination and large, robust strips for easy insertion.
  • Memory with pre-/post-meal markers, activity and control markers; up to six audible alarms (three for glucose, three for ketones).
  • Automatic temperature compensation via integrated thermo sensor.


Multimedia
  • Product videos available (embedded YouTube demos and brochure videos).


Package & accessories
  • Meter compatible with GLUCOFIX TECH Sensor (blood glucose strips) and GLUCOFIX TECH ß-Ketone Sensor (ketone strips).
  • Compatible with Glucoject Dual Plus lancets; eco-friendly pocket case available (recycled PET, PVC-free).


Usage & indications
  • Intended for self-monitoring of blood glucose (SMBG) and ketonemia.
  • Also indicated for use in gestational diabetes management.


Caractéristiques / spécifications techniques
  • Product: GLUCOFIX TECH GK
  • Manufacturer: A. Menarini Diagnostics S.r.l.
  • Tests: Glycaemia (blood glucose) and ketonemia
  • Strip coding: Not required
  • Blood sample: fresh capillary whole blood
  • Temperature compensation: automatic via integrated thermo sensor
  • Batteries: 2 × 3.0 V lithium (CR2032)
  • Battery life: minimum 900 tests or about 1 year (based on 2–3 tests/day)
  • Memory: 730 blood glucose results and 100 ketonemia results with markers, dates and times (when full, new results replace oldest)
  • Data management: pre-/post-meal markers, physical activity and control markers
  • Alarms: up to six audible alarms (three for blood glucose, three for ketonemia)
  • Data transfer: via dedicated USB cable or built-in NFC
  • Averages: 1, 7, 14, 30, 60 or 90 day averages (blood glucose)
  • Automatic shutdown: after 90 s inactivity before test (strip inserted), after 60 s post-test inactivity and for certain error states; 5 s after specific error/status icons
  • Dimensions: 107 × 58 × 13.5 mm
  • Weight: 46 g (without batteries)
  • Operating conditions (instrument): blood glucose test 5–45°C; ketonemia test 10–40°C; relative humidity 20–90% (non-condensing) for blood glucose, <85% for ketone test
  • Conservation conditions (instrument): −20–50°C; relative humidity 20–90%
  • Control solution storage temperature: 4–30°C
  • Operating environment: complies with electromagnetic compatibility (EMC) standards
  • EU Directive / Classification: 98/79/EC, Annex II, List B
  • Device standard: EN ISO 15197:2015
  • Blood glucose strip technical data: units mg/dL and mmol/L; test range 20–600 mg/dL (1.1–33.3 mmol/L); hematocrit compensated range 10–70%; strips: GLUCOFIX TECH Sensor; sample volume 0.5 µL; analysis duration 5 seconds; methodology: electrochemical, glucose oxidase (GOD) with hexacyanoferrate(III) mediator; storage 4–30°C, relative humidity 20–90%; expiry: 24 months unopened, 12 months after opening bottle.
  • Ketonemia strip technical data: unit mmol/L; test range 0.1–8.0 mmol/L; hematocrit compensated range 20–60%; strips: GLUCOFIX TECH ß-Ketone Sensor; sample volume 0.8 µL; analysis duration 8 seconds; methodology: electrochemical based on ß-hydroxybutyrate dehydrogenase with 1,10-phenanthroline-5,6-dione mediator; storage 4–30°C; expiry: individually packed aluminium blisters, valid 18 months from manufacturing.