video corpo

Dental implant brush i-Brush1

Dental implant brush - i-Brush1 - Neobiotech
Dental implant brush - i-Brush1 - Neobiotech
Dental implant brush - i-Brush1 - Neobiotech - image - 2
Dental implant brush - i-Brush1 - Neobiotech - image - 3
Dental implant brush - i-Brush1 - Neobiotech - image - 4
Dental implant brush - i-Brush1 - Neobiotech - image - 5
Add to favorites
Compare this product

Description

Short description
Disposable implant brush designed for mechanical debridement and cleansing of implant surfaces in peri-implantitis treatment. Intended for access to narrow and deep non-circumferential defect areas without damaging the implant surface.

Certification
CE certified.

Features
  • Disposable stainless-steel brush for targeted debridement of implant threads
  • Flexible stem to facilitate access to narrow cavities and deep defects
  • Designed for granulation tissue removal and mechanical cleansing of contaminated implant surfaces
  • Suitable for narrow, deep non-circumferential defects where conventional instrumentation is limited
  • Reported clinical use at approximately 8,000 rpm for mechanical cleansing
  • Compatible with adjunctive decontamination: chlorhexidine gluconate, phosphate etching, saline rinsing
  • Can be combined with R-Brush for bulk granulation tissue removal
  • Supports subsequent surface treatments such as air abrasion with β-TCP to promote remineralization

Clinical cases (summaries)
  • Clinical case 1: Peri-implantitis treated with granulation tissue removal and mechanical cleansing using R-Brush and i-Brush1. R-Brush used for bulk tissue removal and mechanical cleansing at ~8,000 rpm with copious irrigation. i-Brush1 applied in narrow, deep non-circumferential defects. After decontamination with chlorhexidine gluconate, the SLA surface was phosphate-etched (10 s) and rinsed with saline. β-TCP powder applied by air abrasion to promote remineralization.
  • Clinical case 2: Peri-implantitis treated with i-Brush1. Pre-operative radiograph documented. Granulation tissue removed by i-brushing, defect filled with bone graft material (e.g., Bio-Oss) and wound closed by suturing. Post-operative radiograph documented.
  • Clinical case 3: One-year follow-up after peri-implantitis treatment with i-Brush1. Initial severe peri-implant bone loss and implant exposure with flap elevation. Each contaminated implant thread cleaned with i-Brush1 for approximately 3 minutes at ~8,000 rpm. i-brushing reported to produce a renewed rough surface; follow-up imaging and clinical assessment performed.

Technical specifications
  • Product type: Disposable implant brush
  • Primary use: Granulation tissue removal and mechanical cleansing in peri-implantitis treatment
  • Recommended operating speed: 2,000–10,000 rpm (clinical reports ~8,000 rpm)
  • Example cleaning time (clinical report): ~3 minutes per contaminated implant thread
  • Tip material: titanium-alloy; brush filaments: stainless steel
  • Compatible adjuncts/procedures: chlorhexidine gluconate decontamination, phosphate etching (10 s), saline rinsing, air abrasion with β-TCP, bone grafting materials (e.g., Bio-Oss)
  • Packaging: disposable, box of 10 units
  • Certifications: CE

Catalogs

No catalogs are available for this product.

See all of Neobiotech‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.