Type B2 biosafety cabinet LABGARD ES TE
laboratoryfor researchfor clean rooms

type B2 biosafety cabinet
type B2 biosafety cabinet
type B2 biosafety cabinet
type B2 biosafety cabinet
type B2 biosafety cabinet
type B2 biosafety cabinet
Add to favorites
Compare this product
 

Characteristics

Class
type B2
Applications
laboratory, for research, for clean rooms, containment
ISO class
ISO class 5
Configuration
benchtop
Certifications
NSF/ANSI 49
Lighting
with LED light
Other characteristics
with HEPA filter, stainless steel, with sloped sliding window
Filtration efficiency

99.99 %

Window opening

203 mm
(7.99 in)

External width

1,362 mm, 1,972 mm
(53.62 in, 77.64 in)

External depth

823 mm
(32.4 in)

External height

1,575 mm
(62.01 in)

Internal width

1,178 mm, 1,788 mm
(46.38 in, 70.39 in)

Internal depth

530 mm
(20.87 in)

Internal height

640 mm
(25.2 in)

Weight

222 kg, 308 kg
(489.43 lb, 679.02 lb)

Description

The NU-560 combines durable construction and an efficient motor with a control system providing the safety and monitoring appropriate for the demanding work done in a Class II Type B2 biological safety cabinet. Overview The NU-560 biological safety cabinet uses a DC ECM motor that economizes energy while evenly distributing laminar downflow air through a flexible plenum and retaining enough power to overcome supply HEPA filter loading and minimize filter changes. This cabinet’s construction provides the user with a work zone whose side and back walls are constructed from a single piece of stainless steel for enhanced containment and easy cleanability. The LED bulbs efficiently illuminate the procedure inside while a single-piece dished work tray traps most spills above it but includes a prop rod to allow cleaning underneath. An outlet is placed on the left front faring and a cord-pass through is built into the right sidewall for the user’s convenience. The exhaust is powered by an external facility blower that is interlocked with the cabinet’s own motor through a redundant system to provide two layers of protection that minimize the risk of blowing air out of the cabinet should the external blower fail: cabinet exhaust is monitored by not only a mechanical pressure switch but also a differential velocity pressure flow grid. A touch screen displays the readings from both this flow grid and a down flow sensor in the work zone at all times for the cabinet operator. Models are available that meet the commonly respected NSF/ANSI 49 standard for biosafety cabinets.

Catalogs

No catalogs are available for this product.

See all of NuAire Laboratory Equipment‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ANALYTICA 2024
ANALYTICA 2024

9-12 Apr 2024 München (Germany) Hall B1.510 - Stand Vide

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.