OCT ophthalmoscope REVO 2 FC130
non-mydriatic retinal cameraOCT pachymetryfundus imaging

OCT ophthalmoscope - REVO 2 FC130 - Optopol Technology - non-mydriatic retinal camera / OCT pachymetry / fundus imaging
OCT ophthalmoscope - REVO 2 FC130 - Optopol Technology - non-mydriatic retinal camera / OCT pachymetry / fundus imaging
Add to favorites
Compare this product

Characteristics

Type of instrument
non-mydriatic retinal camera, OCT ophthalmoscope
Examination
fundus imaging, OCT pachymetry

Description

Product overview
REVO 2 is a next-generation Spectral-Domain OCT platform with integrated widefield color fundus imaging, designed for comprehensive ophthalmic diagnostics. It combines widefield OCT (up to ~115° with optional UWF module) and high-resolution color fundus photography to visualize central and peripheral retinal structures in a single examination. The system includes multimodal fundus imaging (green/blue FAF, FA, ICGA) and embedded AI tools for image enhancement, segmentation, anomaly detection and result support.

Key benefits
  • Unified platform for OCT and fundus imaging with widefield and ultra-widefield options
  • Integrated non-mydriatic 20.3 MP color fundus camera for automated high-resolution retinal capture
  • Optional ultra-widefield (UWF) module for mosaic and single-scan peripheral imaging up to ~200° (mosaic) or ~115° (UWF lens)
  • Full Auto SD-OCT workflow for posterior and anterior segment capture; optional OCT-A angiography
  • Embedded AI: image enhancement (AI DeNoise), segmentation (retina, anterior, cornea), drusen detection/quantification and fundus anomaly detection

Multimodal Fundus Imaging
Selectable autofluorescence and angiography modes to support comprehensive retinal assessment.
  • FAF Green – Green fundus autofluorescence
  • FAF Blue – Blue fundus autofluorescence
  • FA – Fluorescein angiography
  • ICGA – Indocyanine green angiography

Ultra-Widefield Fundus Imaging
UWF Mosaic Photo mode captures peripheral retina using multiple fixation positions and automatically generates true-color ultra-widefield mosaics without pharmacologic dilation. Mosaic configurations include Horizontal ×3, Vertical ×3, ×5, ×9 and Custom ×2–9.

Widefield & Ultra-Widefield OCT
High-resolution OCT (23 mm wide / 6 mm deep). REVO 2 delivers widefield OCT up to 90° and, with the optional UWF module, up to ~115° in a single scan. Supports 3D analysis, Enhancement Mode averaging, Angio OCT and Full Range scanning for extended depth imaging.

Full Auto SD-OCT
One-button acquisition for posterior and anterior segment scans with multiple alignment modes (fully automatic, automatic, manual) and live interactive fundus tracking (AccuTrack / iTracking). Internal OLED and external fixation targets available.

Color Fundus Camera & Fundus Analysis Tools
The non-mydriatic integrated fundus camera provides automated high-resolution imaging and analysis tools including:
  • Single-eye and bilateral imaging
  • Chronological comparison of fundus photographs (×4 and ×8 progression views)
  • Image enhancement: Emboss+, Emboss-, Cobalt, Digital Cobalt, Digital Red-Free
  • Measurement functions: area, distance, C/D
  • AI anomaly detection

AI-Powered features
Embedded AI tools support OCT and fundus workflows:
  • AI Fundus Anomaly Detection – highlights suspicious areas in fundus images
  • AI Drusen Detection & Monitoring – detection and quantification by number, area and volume for longitudinal follow-up
  • AI Segmentation – posterior segment, anterior chamber and cornea segmentation for precise layer boundary detection
  • AI DeNoise – enhances single tomograms to quality comparable to averaged scans

Other imaging modes & modules
  • OCT-A Angiography (optional) – dye-free microvasculature imaging with fast acquisition (1.6 s standard / 3 s high resolution)
  • T-OCT™ Topography (optional) – corneal curvature maps and keratoconus indices
  • B-OCT® Biometry (optional) – automated ocular biometry and integration with OCT
  • IOL Calculation (requires Biometry module and license) – modern IOL formulas and IOLCon.org database support
  • Anterior chamber imaging & OCT gonioscopy – automated anterior analysis and angle mapping without adapters
  • Anterior segment photography & Meibography (infrared) for eyelid and meibomian gland assessment

Technical specifications (key data)
Parameter | REVO 2 FC130 | REVO 2 FC
OCT technology | Spectral-Domain OCT | Spectral-Domain OCT
Scanning speed | 130,000 A-scans/s | 80,000 A-scans/s
Axial resolution | In tissue 5.5 μm; digital 2.8 μm | In tissue 5.5 μm; digital 2.8 μm
Central wavelength | 850 nm | 850 nm
Bandwidth | 50 nm | 50 nm
Lateral resolution | 12 μm | 12 μm
Axial range | Standard 2.8 mm; Full Range ~6.0 mm | Standard 2.8 mm; Full Range ~6.0 mm
Minimum pupil size (OCT) | 2.0 mm | 2.0 mm
Focus adjustment | -25 D to +25 D | -25 D to +25 D
Fundus tracking | Live / interactive (AccuTrack, iTracking) | same
Dimensions / Weight | 490 × 350 × 530 mm / 30 kg | same
Power | 100–240 V, 50/60 Hz; consumption 90–110 VA | same
UWF (optional) - UWF scan angle | ~115° ±5% | ~115° ±5%
Fundus camera | Built-in 20.3-megapixel CMOS, non-mydriatic, color/IR/FAF/FA/ICGA options | same
Fundus camera FOV | Standard 90° (60°) ±5%; mosaic up to 198° | same

Product specifications
  • Product name: REVO 2
  • Brand: Optopol
  • Platform: SD-OCT with integrated widefield fundus camera
  • OCT scanning speed: up to 130,000 A-scans/s (FC130) or 80,000 A-scans/s (FC)
  • Axial resolution: in tissue 5.5 μm; digital 2.8 μm
  • Central wavelength: 850 nm; bandwidth 50 nm
  • Lateral resolution: 12 μm
  • Axial range: standard 2.8 mm; Full Range ~6.0 mm
  • Minimum OCT pupil: 2.0 mm
  • Focus adjustment: -25 D to +25 D
  • Fundus camera: built-in 20.3 MP CMOS, non-mydriatic, color/IR/FAF/FA/ICGA options
  • Fundus camera FOV: standard 90° (60°) ±5%; small pupil 67° (45°) ±5%; mosaic up to 198°
  • UWF optional: ~115° single-scan OCT; mosaic color up to ~200°
  • AI features: anomaly detection, drusen detection & quantification, segmentation (retina/anterior/cornea), DeNoise
  • Angiography: OCT-A modes and FA/ICGA (optional)
  • Dimensions / Weight: 490 × 350 × 530 mm; 30 kg
  • Power: 100–240 V, 50/60 Hz; consumption 90–110 VA

Catalogs

No catalogs are available for this product.

See all of Optopol Technology‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.