video corpo

Phlebology laser M2
dermatologyENT surgerygynecological surgery

Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 2
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 3
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 4
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 5
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 6
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 7
Phlebology laser - M2 - Pioon Medical Laser - dermatology / ENT surgery / gynecological surgery - image - 8
Add to favorites
Compare this product

Characteristics

Applications
dermatology, gynecological surgery, ENT surgery, disc decompression surgery, colorectal surgery, aesthetic medicine, varicose vein treatment, phlebology
Amplifying medium
diode
Ergonomics
tabletop
Laser class
class 4
Wavelength

Min.: 450 nm

Max.: 1,940 nm

Average power

Min.: 10 W

Max.: 60 W

Weight

5 kg
(11.02 lb)

Description

Product overview
The M2 medical diode laser is a multi-wavelength surgical platform offering selectable wavelengths (examples: 450nm, 520nm, 808nm, 980nm, 1064nm, 1210nm, 1470nm, 1940nm). Designed for diverse clinical specialties, it supports high-power single, dual and up to three-wavelength simultaneous outputs, features a 7-inch Retina HD display and the SmartOS 2.0 interface for fast, intuitive operation.

Key features
  • Multi-wavelength selection for tailored clinical use (examples: 808nm, 980nm, 1064nm, 1470nm).
  • High-power output for efficient cutting, coagulation and vaporization.
  • Dual- and triple-wavelength simultaneous output to combine effects for improved haemostasis, precision and healing.
  • Wide clinical applicability: dermatology, ENT, gynecology, proctology, vascular (EVLT), orthopedics (PLDD), general and aesthetic surgery.
  • Integrated safety: overheat and overcurrent protection, automatic fault detection.
  • Professional support: training, maintenance and technical assistance services.


Hardware performance
Robust ABS+PC unibody casing, integrated Pioon‑Eye design with SMA905 fiber interface and laser indicator, global voltage adapter. Powerful CPU enables multi-wavelength simultaneous output; example standard configuration: 980nm 30W + 1470nm 15W. Further wavelength and power customizations available within product capabilities.

Software intelligence
SmartOS 2.0 provides a smartphone-inspired, touch-driven UI with preset protocols, expert customization, rapid parameter adjustment and precise energy control to streamline clinical workflows.

Wavelength combinations
  • 450nm — 10W
  • 520nm — 10W
  • 808nm — 30W
  • 980nm + 1470nm — 60W + 30W
  • 1064nm — 10W
  • 1210nm + 1470nm — 10W + 10W
  • 1470nm — 20W
  • 1940nm — 10W


Clinical procedures & recommended wavelengths (summary)
  • EVLT (endovenous laser treatment): 1470nm and 1940nm for strong water/hemoglobin absorption and effective vein closure.
  • PLDD (percutaneous laser disc decompression): 980nm for precise disc targeting with limited collateral thermal damage.
  • Proctology (hemorrhoids, fistulas): 1470nm for coagulation and tissue ablation.
  • Gynecology (vaginal tightening, wart removal): 980nm and 1470nm for delicate mucosal treatments and regeneration.
  • Aesthetic procedures (laser-assisted facelift, lipolysis): 980nm, 1210nm and 1470nm for fat liquefaction and collagen stimulation.


Medical-grade instruments and accessories
  • Handpieces: proctology, surgical zoom, focusing (300/400µm fiber; spot 1/2/3mm), surgery (SMA905/FC), ENT set (7 cannulae, 200–600µm, autoclavable), Lipo Handpiece Pro (5 cannulae, 600µm), gynecology handpiece (600µm, SMA905).
  • Fibers & tips: polyimide-coated fibers, conical hemorrhoid probe (600µm), radial fibers (SMA905, >90% transmittance, ETO sterilized), Laserlift tips (200–1000µm), bare fibers (200/300/400µm, 3m).
  • Accessories: protective goggles (980–2700nm), multilingual manual, transport box, bare fiber holder, IEC 60601-1 medical-grade plug, optional Bluetooth or waterproof medical-grade foot pedal.


Technical specifications
  • Screen: 7 inches, Retina level
  • Dimensions: 290mm x 250mm x 130mm
  • Shell color: Moon White
  • Storage: 32GB (approx. 1,000,000 protocols + 500 HD tutorials)
  • Fiber connector: SMA905
  • Operating system: SmartOS 2.0
  • Standards: IEC 60601-1:2020; IEC 60601-1-2:2020; IEC 60601-2-22:2019; IEC 60825-1:2014; IEC 62304:2015; IEC 62366-1:2020; ISO 14971:2019; ISO 24971:2020; ISO 10993-1:2018; ISO 15223-1:2021