Measured parameter
ECG, RESP, TEMP, etCO2, NIBP, SpO2
Applications
intensive care, ambulatory, clinical, for animal research, veterinary
Configuration
portable, trolley-mounted
Screen size

12.1 in

Description

Attractive and Durable out casing Ergonomie handle design Anywhere visible design 3 level Andible and visuable Screen can be selected from 10", 12.1" to 15" TFT LCD Durable trim knob 12" color TFT Touch screen,Screen is detachable,Separate module Application:Adult/Pediatric/Neonate/Medicine/Surgery/Operating Room/ ICU/ CCU Built-in rechargeable battery Date Storage: Trend diagram/table: 7*24h NIBP review: 400 events Wave review: 100min Alarm review: 100 alarms events Support drug: conventration titration anaysis ST Segment: ST Segment Range: -0.2mV ~ +2.0mV Accuracy: 0.02mV SPO2 Range: 0 ~ 100%Resolution: 1% Precision: 70% ~ 100%; ±2DIGIT 0% ~ 69%: ±no definition given Pulse Rate Range: 20 ~ 300bpm Resolution: 1bpm Precision: ±3bpm ECG 5-leads: RA, LA, LL, RL, V Lead mode: I, II, III, aVR, aVL, aVF, V Increase: *250, *500, *1000, *2000 Sensivity: > 200uV (Peak-to-Peak value) Input impedance: > 5 (megohm) Bandwish: Surgery: 1 ~ 20Hz Monitor: 0.5 ~ 40Hz Diagnostic: 0.05 ~ 130Hz CMRR: ³ 100dB Polarization Voltage: ± 300mV Baseline Recovering Time: After defibrillator < 3seconds Signal Range: 8mV (Peak-to-Peak value) Calibration Signal: 1mV, precision ±5% RESP: Method: RA-LL impedance Resp Impedance range: 0.3~3 d Base Impedance range: 200 d ~ 4000 d Bandwidth: 0.1 ~ 2.5Hz Resp rate: Adult 0 ~ 120BrPM Neonate/Pediatric: 0 ~ 150BrPM Resolution: 1BrPM Precision: ±2BrPM Asphyxia Alarm: 10 ~ 40 seconds NIBP: Measurement interval of auto mode: 1,2,3,4, 5,10,15,30,60,90,120,180,240,480minutes Measuring Time of STAT Mode: 5 minutes PR range: 40 ~ 240bpm Measure & alarm range: SYS: 40~270mmHg; DIA: 10~215mmHg;MEAN: 20~235mmHg Static pressure range: 0~300mmHg (±3mmHg)

VIDEO

Catalogs

Other Promed Group products

Plug-in Patient monitor

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.