Portable patient monitor PM-12 Plus
trolley-mountedECGRESP

portable patient monitor
portable patient monitor
portable patient monitor
portable patient monitor
portable patient monitor
portable patient monitor
Add to favorites
Compare this product
 

Characteristics

Configuration
portable, trolley-mounted
Measured parameter
ECG, RESP, TEMP, etCO2, NIBP, SpO2
Applications
intensive care, clinical, ambulatory, veterinary, for animal research
Screen size

12.1 in

Weight

5 kg
(11 lb)

Pulse rate

Min.: 20 unit

Max.: 300 unit

Description

12.1-inch high-resolution color TET LCD display. Thinner and lighter in design, convenient and portable for users. Real-time S-T segment analysis, pacemaker detection. Various interfaces: standard screen, trend screen, oxy CRG screen, NIBP list screen, big front screen. 3-level audio/visual alarms. Efficient resistance to interference of defibrillator and HF knife. Up to 400 groups NIBP list, 6000seconds, ECG waveform recall, 60 alarm event records recall, 7-day trend chart in storage. Built-in rechargeable lithium battery, 2-hour working capability. Wireless central monitoring system applicable to ICU/CCU/OR SPO2 Range: 0 ~ 100%Resolution: 1% Precision: 70% ~ 100%; ±2DIGIT 0% ~ 69%: ±no definition given Pulse Rate: Range: 20 ~ 300bpm ECG 5-leads: RA, LA, LL, RL, V Lead mode: I, II, III, aVR, aVL, aVF, V Increase: *250, *500, *1000, *2000 Sensivity: > 200uV (Peak-to-Peak value) Input impedance: > 5 (megohm) Bandwish: Surgery: 1 ~ 20Hz Monitor: 0.5 ~ 40Hz Diagnostic: 0.05 ~ 130Hz CMRR: ³ 100dB Polarization Voltage: ± 300mV Baseline Recovering Time: After defibrillator < 3seconds Signal Range: 8mV (Peak-to-Peak value) Calibration Signal: 1mV, precision ±5% RESP: Method: RA-LL impedance Resp Impedance range: 0.3~3 d Base Impedance range: 200 d ~ 4000 d Bandwidth: 0.1 ~ 2.5Hz Resp rate: Adult 0 ~ 120BrPM Neonate/Pediatric: 0 ~ 150BrPM Resolution: 1BrPM Precision: ±2BrPM Asphyxia Alarm: 10 ~ 40 seconds NIBP: Measurement interval of auto mode: 1,2,3,4, 5,10,15,30,60,90,120,180,240,480minutes Measuring Time of STAT Mode: 5 minutes PR range: 40 ~ 240bpm Measure & alarm range: SYS: 40~270mmHg; DIA: 10~215mmHg;MEAN: 20~235mmHg Static pressure range: 0~300mmHg (±3mmHg)

VIDEO

Other Promed Technology products

Plug-in Patient monitor

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.