Nuclear imaging test phantom
for MRIfor tomographyfor CT scan

Nuclear imaging test phantom - Pure Imaging Phantoms - for MRI / for tomography / for CT scan
Nuclear imaging test phantom - Pure Imaging Phantoms - for MRI / for tomography / for CT scan
Nuclear imaging test phantom - Pure Imaging Phantoms - for MRI / for tomography / for CT scan - image - 2
Nuclear imaging test phantom - Pure Imaging Phantoms - for MRI / for tomography / for CT scan - image - 3
Nuclear imaging test phantom - Pure Imaging Phantoms - for MRI / for tomography / for CT scan - image - 4
Nuclear imaging test phantom - Pure Imaging Phantoms - for MRI / for tomography / for CT scan - image - 5
Add to favorites
Compare this product

Characteristics

Type of calibration
for nuclear imaging, for MRI, for tomography, for CT scan, for PET and SPECT
Area of the body
general purpose
Patient type
pediatric

Description

Product description
A set of 7 transparent PMMA (acrylic) cubes, each 17 × 17 × 17 mm, containing a 5 mm diameter spherical cavity. Cavities can be filled with radionuclide solutions, CT contrast media or MR contrast agents and are sealed with a nylon screw. Supplied as a set for multimodal imaging quality assurance and registration tasks.

Multiple uses of the Nuclear Alignment Markers:
  • Point source markers
    Provide defined reference points for quantitative assessment of alignment accuracy between PET, CT and MR systems, enabling reproducible measurements across repeated acquisitions.
  • Imaging aids
    Support precise image registration in multimodal and fusion imaging workflows and act as stable fiducials for testing co-registration algorithms and validating processing pipelines.
  • Clinical skin markers
    When applied externally, serve as visible fiducials to mark anatomical landmarks for acquisition alignment and to assess registration performance in the presence of patient motion.

Technical specifications
  • Material: PMMA (acrylic)
  • Quantity: set of 7 cubes
  • Cube dimensions: 17 × 17 × 17 mm
  • Spherical cavity diameter: 5 mm
  • Fillable with: radionuclide solutions, CT contrast media, MR contrast agents
  • Seal: nylon screw
  • Delivered: complete set with sealing screws


Handling and safety
  • Intended for use by trained personnel in clinical or research imaging environments.
  • When filled with radionuclides, follow institutional radiation safety regulations and local legislation.
  • Inspect seals and packaging before use; avoid exposure to high heat or mechanical stress to preserve PMMA integrity.