Monopolar cutting electrosurgical unit Vesalius MC
bipolar cuttingmonopolar coagulationbipolar coagulation

Monopolar cutting electrosurgical unit - Vesalius MC - Telea Medical - bipolar cutting / monopolar coagulation / bipolar coagulation
Monopolar cutting electrosurgical unit - Vesalius MC - Telea Medical - bipolar cutting / monopolar coagulation / bipolar coagulation
Monopolar cutting electrosurgical unit - Vesalius MC - Telea Medical - bipolar cutting / monopolar coagulation / bipolar coagulation - image - 2
Add to favorites
Compare this product

Characteristics

Features
monopolar cutting, bipolar cutting, bipolar coagulation, monopolar coagulation
Medical procedure
gynecological surgery, plastic surgery, dermatological surgery
Technology
radiofrequency, high-frequency
Cutting power

90 W, 160 W

Coagulating power

100 W

Frequency

4 MHz, 8 MHz, 12 MHz, 16 MHz

Description

Vesalius MC is monopolar and bipolar device, purposely designed for a wide range of surgical treatments. It is an advanced electrosurgical generator of the Vesalius product line. The MC device has been developed for usage in multiple outpatient surgeries and operating rooms. Thanks to the specific combination of the high frequencies of the QMR Technology, the Vesalius MC product allows cutting and coagulating due to a resonance effect on the tissue. In addition, Vesalius MC has also a fulguration function (spray coagulation). All of the functions can be activated at the same time both from the handpiece and the pedal. Thanks to the QMR Technology the cutting function is caused by a breakdown of molecular bonds at low temperature. Thereby the thermal damage is limited and allows the Surgeon to provide extremely delicate surgical procedures. The bipolar coagulation of Vesalius generators is recognized for precision and effectiveness. Differently from the standard electrosurgical high frequency devices (which cause the vessels collapse and tissue necrosis), Vesalius deploys a peculiar waveform (slightly out of resonance) that increases the temperature up to 63-65°C. This triggers the denaturation processes of fibrinogen which turns into fibrin and coagulates the blood, without thermal damage of vessels. FEATURES Better tissue healing No irrigation required 5 different operating functions Very low working temperature No carbonization of the tissues Reduced lateral thermal diffusion Monopolar and bipolar operating mode FIELDS OF APPLICATION Maxillofacial Surgery Pediatric Surgery

Catalogs

No catalogs are available for this product.

See all of Telea Medical‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.