- Laboratory >
- Laboratory infrastructure >
- Laboratory fume hood
Laboratory fume hoods
... working hours counter for optimum user protection aganist odor and fume contamination, this unit creates a safe working environment. A special hood facilitating the exhaust of solvent fumes ...
LABTECH Solution
Laminar Flow Hood with Lead GlassDedicated to the laboratory and industry use, specifically for the protection of the product manipulated. Moreover, ensures excellent laminar flow at the worktop level ...
Recommended for capturing fumes and gases from hot oil or water baths, heating plates, muffles, stoves and chromatography, as well as any application that generates heat or non-toxic vapour. Not recommended for use with ...
Specially designed to extract combustion fumes and flame vapours. Can also be used in graphite furnaces for atomic absorption instruments to prevent the atoms from spreading into the general laboratory ...
The EdgeGARD® VF is a vertical-flow recirculating air clean bench that provides protection for samples and work procedures where product protection and particulate control are required. ISO Class 4 (Class 10) cleanliness (for 0.5 ...
The Baker Company
... standard for containment - Uses up to 80% less energy than a standard fume hood Description For use in pharmaceutical, chemical, biological, and toxicological laboratory settings. ...
Flow Sciences
... complex conditioning in the laboratory by up to 30% compared to conventional fume cupboard. EXPLORIS EcoPlus® reduces the consumption of expensive conditioned air in the laboratory by ...
... distillation and walk-in fume cupboards are used when a large working height is required, for example in distillations or preparative column chromatography. Distillation fume cupboards are equipped ...
... exhaustive control and great flexibility. For more information, please see our product data sheets. Fume extraction hood Atomic absorption hood Wall-mounted hood Extraction ...
Face velocity: 0.3 m/s - 0.8 m/s
Length: 1,040 mm
Depth: 800 mm
Designed to provide personnel protection from toxic fumes and hazardous volatile vapours, our standard fume hoods are reliable and easy to use. Its inbuilt ventilation system with a front window eliminates ...
Biohazard vertical laminar flow hood, class II A (if provided with the outlet exaust adapter fitting, Class A/B3). The hood is TÜV certified, according to UNI EN 12469. The cabinet has been projected ...
Teknolabo A.S.S.I.
Sterile Laminar flow hood in Class I not Biohazard designed for the protection of both operator and product. The flow activa hood is suitable for the handling of low biological risk pathogens (cat 1 e ...
Teknolabo A.S.S.I.
Horizontal laminar flow hood, Class I not Biohazard. The horizontal air stream, directed towards the operator, is obtained through an HEPA filter, ensuring class 100 sterile conditions in the working room. Motor-fan ...
Teknolabo A.S.S.I.
Face velocity: 0.4 m/s - 0.6 m/s
Power: 250 W
Length: 750, 900, 1,200, 1,500, 1,800 mm
Topair’s Polypropylene Ductless Fume Hood – PRO with EN and ASHRAE certification provides a safe work environment for lab staff working with acids and harsh chemicals. The hood includes ...
TopAir Systems, Inc.
Face velocity: 0.5 m/s
Power: 37, 67 W
Depth: 711 mm
... Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you ...
Air Science
Power: 70 W
Depth: 750 mm
Height: 1,400 mm
Required occupational exposure limits are maintained Testing of the air equipment according to EN 14175 Part 3 (5.4.4) Maximum user safety Robust construction made of chemically resistant, anodised aluminium profiles Transparent side ...
Inertec
This safety workbench protects you reliably in your work in pathology and histology laboratories against inhaling solvent vapors. The table extraction prevents the release of vapors, e.g. formaldehyde or toluene.
Weiss GWE GmbH
Height: 260 cm
Available in the distillation version with table or trolley with lowered top, placed inside the work chamber.
Length: 1,020 mm
Depth: 621 mm
Height: 1,920 mm
Fume hood SHV-1,0-“Laminar-S.” is designed for use in laboratories providing operator’s protection when working with chemically harmful materials and for their effective removal. Application ...
LAMSYSTEMS
Canadian-made vertical and horizontal laminar flow hoods create the ideal environment for excellent product protection, where particulates are not harmful to the operator. The vertical or horizontal airflow blankets the ...
Healthmark
The exhaust unit guarantees a laboratory environment free of pollutants while slicing and preparing histological slide preparations. Airflow travels over the entire working area and is vacuumed out backwards, which provides ...
... tested in accordance with ASHRAE 110 A Crossover Fume Hood A true crossover fume hood for research and teaching spaces. The natural light, sight lines, and ergonomics of a full view ...
Mott Manufacturing
Depth: 800 mm
Height: 1,510 mm
- Glass height transducer with flowmeter and ventilation adjustment - Automatic management of ventilation speed, functions delay and grossing basins rinsing - Foot-pedal for water control valve - Arrangement for DIGIpath ULTRA - Lighting ...
... industry your laboratory is serving, from pharmaceutical to academia, Envair's custom ducted fume cupboards provide first-class protection for scientific professionals. Fully designed and developed ...
Depth: 33 in
Height: 56 in
Designed to reduce turbulence, air foil fume hoods have a gentle slope on the bottom front air foil to reduce exterior air patterns and increase lab safety. To minimize turbulence, the Airfoil Fume Hood ...
Labscape
Height: 56 in
... 100 series airfoil-type fume hood features a 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom, which results in minimized turbulence and increased performance. Like ...
Air Master Systems Corporation
Depth: 23.5 in
Height: 20 in
Bench-top fume hood for DigiPREP Jr. and DigiPREP MS digestion blocks. Replacement air is drawn through the dual HEPA kits offering cleaner ambient air. An adjustable speed blower unit (sold separately, ...
Horizontal laminar flow clean bench LHCB-A10 is a compact structure providing unmediated HEPA-filtered air horizontally over the work area with purification rank of 100 and are equipped with removable protective glass to provide enclosed ...
Your suggestions for improvement: