- Secondary care >
- Orthopedic surgery >
- Distal compression plate
Distal compression plates
Length: 188, 30 mm
... arthrodeses in adults. Volar Rim plates • Precontoured plates for anatomical fit • Lateral lip allowing the plate positioning on the watershed line. TECHNICAL FEATURES Anatomical shape Precontoured ...
Newclip Technics
Length: 44, 54, 64, 74, 94 mm
Thickness: 2 mm
Number of holes: 7, 8, 10, 6, 5 unit
... high technology adopted variable angle distal radius plates are frequently used. Thanks to its cutting-edge development and manufacturing power, Osteonic proudly meets all the demands from markets with Signex Distal ...
OSTEONIC
Length: 138, 68, 82, 96, 124 mm
Thickness: 3 mm
Number of holes: 8, 3, 4, 5, 6 unit
... This Plate is designed to provide fracture fixation and stability for lateral third clavicle fractures, malunions, and nonunions. It is designed to anatomically fit the distal clavicle Multiple distal ...
DTM - Deva Tibbi Malzemeler
Length: 68, 120 mm
Thickness: 3 mm
Number of holes: 8, 9, 12 unit
... Distal Humerus Lateral VAL Plates Properties It allows an off-axis angle of up to 15° with the 2.7 mm diameter angled screw locking option located in the distal part. Screws from the lateral of the ...
... Indikation: As tension band, neutralization or buttress plate in fibula, distal ulna, olecranon and metatarsus. ...
Dieter Marquardt Medizintechnik
... Anatomically pre-formed plate design for right and left leg Rounded edges and flattened plate head minimize the soft tissue irritation High primary stability thanks to Ø 3.0 mm and Ø 3.5 mm locking cortical screws Polyaxial ...
Intercus
Length: 64, 142 mm
Thickness: 2.6 mm
Number of holes: 9, 3 unit
... P. Width: 14.1 mm D. Width: 11.2 mm This Plate is indicated for intra-articular and supracondylar fractures (osteotomies, and nonunions) of the distal humerus *Pre-contured design *Undercuts for reduced vascular ...
Length: 116, 269 mm
Thickness: 3.5 mm
Number of holes: 13, 3 unit
... : – Small Locking Plate Instrument Set – Large Locking Plate Instrument Set Series: Small Locking Plate Part: Distal Bone: Tibia Description Distal Medial ...
Boneunion Medical
Length: 70, 97, 124, 151, 178 mm
Thickness: 2.5 mm
Number of holes: 4, 6, 8, 10, 12 unit
... purpose of stabilization and fixation of fractures in the distal extremities of the radius, providing recovery and alignment of the member. The rigid connection between the locking screws and the plate allows better clinical ...
Ortobio
Length: 152.5, 110, 134, 170, 201.5 mm
Thickness: 2.5, 1.8 mm
Hole diameter: 1.2, 1.9 mm
... and nonlocking screws. The Eonex tibia plates accepts variable angle locking, non-lockingand compression screws indiameters 2.7mm to 3.5mm. ANTEROLATERAL DISTALTIBIAL PLATE •Orientation: Left, Right • Distal ...
Eonex Medical
Length: 100 mm
... fracture fixation system Customisable plate for every patient by thermo forming and cutting to shape Ability to be tailored during the operation to meet the challenging anatomies Low inventory quantities of plates ...
Length: 140.3, 291.8 mm
Number of holes: 4, 13 unit
... 1. Nonunions 2. Malunions 3. Comminuted Fractures 4. Fractures in Osteopenic bone ...
Taeyeon Medical
Length: 66.5, 78.7, 91.1, 103.2, 113.8 mm
Number of holes: 3, 4, 5, 6, 7 unit
... DISTAL CLAVICLE LOCKING COMPRESSION PLATE Fixation of fractures, nonunions, osteotomies and pseudoarthroses of the clavicle, for the treatment of acromioclavicular dislocations, particularly for patients ...
Ortimplant
Length: 84, 192 mm
Hole diameter: 3.5 mm
Number of holes: 9, 3, 12 unit
... The Vortex polyaxial plate system offers solutions for the whole body with 30 plates and only 3 screws and also ensures cross-referencing between instruments. Key advantages: – polyaxial locking plate ...
Sanatmetal
Length: 88, 101, 138, 114, 124 mm
Number of holes: 7, 10, 9, 6, 8 unit
... - Used for clavicle shaft fracture. - Screw: 11.107.51 3.5 Locking Screw 11.105.03 3.5 Cortical Screw 11.105.20 4.0 Cancellous Screw - Instrument Set: 15001888 Samll Bone Fragment Instrument Set ...
Changzhou Zener Medtec
... Trauma System plates and screws are intended to be used for internal bone fixation for bone fractures, fusions, osteotomies and non-unions appropriate for the size and design of the device. The large plate set components ...
Length: 56, 184 mm
Thickness: 2.3 mm
Hole diameter: 2.7, 3.5 mm
... reinforced polymer. •Polyaxial locking screws - up to 10° trajectory variation. •Circumference radiopaque marking outlining plate contour for positioning & follow-up. Features •Radiolucent: Superior fracture imaging. •Unparalleled ...
CarboFix Orthopedics
Length: 95, 110, 125, 140 mm
Number of holes: 6, 8, 10, 12 unit
... to the medial anterior and concave to the lateral anterior. Anatomical plate; right & left. 4 hole option between 6- 12. TRUE LOCK Superior Distal Clavicle Anatomic Plates are made of Ti6Al4V ...
Truemed Medical
... The Aplus Mini Volar Locking Plate is designed based on analysis from the Asian bone database, specifically tailored to the optimal bone curvature of Asian individuals. The plate is shaped to better fit the distal ...
Aplus Biotechnology
... Y-shaped Distal Humeral Locking Compression Plates(Left/Right) ...
Length: 50, 86, 47, 48 mm
... irritation of soft tissues. • The patented screw- plate locking system allows an easy technique and eliminates the possibility of cross-threading between the screw head and the plate. • Up to seven distal ...
Intrauma
Hole diameter: 4, 3.5, 2.7 mm
Number of holes: 6, 5, 4 unit
... ► Self-tapping Cortex Screw ► Stardrive Self-tapping Locking Screw ► Cancellous Screw The plate is intended for temporary fixation, correction or stabilization in the radius anatomical region. ...
Truemed Group
... insertion (only in some plates). The LOCKING PLATES for RADLOCK DISTAL RADIUS are indicated for: Fixation of displaced intra-articular and extra-articular distal radius fractures Correction ...
Surgival
Length: 56, 66 mm
Number of holes: 5, 4 unit
... Bottom undercuts of the shaft part • limited bone-to- plate contact • better blood circulation of periimplant tissues Compression hole • oblong hole for plate positioning • compression ...
ChM
Length: 2.7, 3.5 mm
... 2.7/3.5mm Distal Medial Humerus Locking Plate 2.7/3.5mm Distal Lateral Humerus Locking Plate Type I 2.7/3.5mm Distal Lateral Humerus Locking Plate ...
Irene Ortho
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group