Length: 135, 69 mm
Number of holes: 3, 8 unit
For fracture of the lateral clavicle and dislocations of the acromioclavicular joint Matching screw: Head: 2.4/2.7 Self-tapping Locking Screw Shaft: 3.5 Self-tapping Locking Screw; 3.5 Cortical screw; 3.5 Cancellous Screw; 4.0 Cancellous Screw
Thickness: 2 mm
... edges of the plate for syndesmotic screw placement outside the plate without compromising plate position • 12 Anterolateral / 6 Straight distal fibula plates • ...
Thickness: 2 mm
... edges of the plate for syndesmotic screw placement outside the plate without compromising plate position • 12 Anterolateral / 6 Straight distal fibula plates • ...
Number of holes: 18, 12, 10, 16, 14 unit
Locking Distal Anterolateral Tibial Plate Ø 3.5 mm screw
255.0170432.15 - ¢3.5/¢4.0Pelvic Symphsis pubis plate,Short 255.0170532.15 - ¢3.5/¢4.0Pelvic Symphsis pubis plate,Medium 255.0170632.15 - ¢3.5/¢4.0Pelvic Symphsis pubis plate,Long
345.1280430.15 - ¢3.5 Distal Tibial Anterolateral LCP 4H,L 345.2280430.15 - ¢3.5 Distal Tibial Anterolateral LCP 4H,R 345.1280630.15 - ¢3.5 Distal Tibial Anterolateral LCP 6H,L 345.2280630.15 ...
Aplus AnteroLateral Distal Tibia Locking Plate designs through analysis of the Asian bone database to better fit the anatomy of Asians. The plate is better in correspondence with Asian ...
Length: 200, 80 mm
Number of holes: 12, 7 unit
Distal Tibial Plate Anterior side Recommended screw : Ø 4.5 or Ø 5 mm
This plate and screw used with PIONEER small instrument system
Length: 152.5, 110, 134, 170, 201.5 mm
Thickness: 2.5, 1.8 mm
Hole diameter: 1.2, 1.9 mm
... accept both locking and nonlocking screws. The Eonex tibia plates accepts variable angle locking, non-lockingand compression screws indiameters 2.7mm to 3.5mm. ANTEROLATERAL DISTALTIBIAL ...
Distal screws aligned with the joint surface Secures Volkmann’s triangle and Chaput fragment
Length: 92 mm
Number of holes: 4 unit
Fusion of tibiotalar joint. The plate is recommended to place on the anterior lateral tibia.
... are intended for the fixation of hand and forearm fractures, osteotomies and arthrodeses in adults. DISTAL ULNA PLATES • Antero-lateral positioning, with an anterior bracket. FIXATION TECHNICAL ...
Length: 20, 35 mm
... anterior, anterolateral, or posterior spinal systems made of compatible materials. The system consists of plates and bone screws. All components are made from medical grade titanium or titanium alloy ...
Length: 48, 54, 58, 64 mm
Hole diameter: 10 mm
Number of holes: 5, 7, 8, 6 unit
... Locking Anatomical plate design Short plate version located directly under the subtalar joint (small and large) Long plate version located directly under the subtalar joint with an ...
I.T.S.
Length: 100, 225 mm
Number of holes: 5, 15 unit
... fracture extending into the diaphyseal area. Anatomical plate; right & left . 7 different hole option between 5-15. TRUE LOCK Distal Tibia Anterolateral Anatomic Plates are ...
Length: 100, 85, 115 mm
Thickness: 3 mm
Hole diameter: 4.1 mm
... lock the plate with the screws in order to build a fixed-angle construct. FEATURES Anodized type II Reduced risk of cold welding Good biocompatibility Shaped design for optimal positioning Conical plate ...
AF Medical
Your suggestions for improvement:
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining