{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Sample volume: 0.02, 0.01 ml
... CCP) is a group of cyclic, 10-20 amino acids, and a collection of short peptide chains containing citrulline. In RA, Anti-CCP IgG has high specificity for rheumatoid arthritis detection ...
Result display time: 135 min
Specificity: 96.3, 97, 95.8 %
Sensitivity: 93.7, 87.7, 92.5 %
... diagnostic kits tested and validated at the INMI Spallanzani using samples obtained from COVID-19 patients. One protocol To improve lab throughput, easy automation, and reduced time to diagnosis, the three kits ...
Result display time: 105 min
... Toxoplasma IgM is an ELISA kit for qualitative detection of IgM antibodies to Toxoplasma Gondii, in human serum, as an aid for diagnosis of active Toxoplasma infection. Clinical Significance: Toxoplasma ...
Result display time: 10 min
Sample volume: 0.02 ml
... already within ten minutes. Each BIOHIT Celiac quick test kit contains reagents for 20 tests. Key benefits of BIOHIT Celiac quick test Determination of tTG IgA/G/M ...
... allergen-specific IgE is of considerable importance for both diagnostic and therapeutic purposes. The method for quantitative determination of specific IgE – capture-ELISA is implemented in the Specific IgE ...
Result display time: 10 min - 15 min
Specificity: 99.6 %
Sensitivity: 99.9 %
... methods, such as the HIV Blood Test Kit, HIV Detection Kit, or HIV Diagnosis Kit, to confirm the diagnosis accurately. Explore the convenience and privacy of At-Home HIV Test ...
... This FluoroSpot kit can be set up in many ways – designed for B cell profiling. Intended use This FluoroSpot Flex kit is intended for the enumeration of B cells secreting mouse IgM, IgG, and IgA using ...
Mabtech
Result display time: 105 min
Sample volume: 0.01 ml
... The Anti-GP2 Iso 1 IgA is a quantitative immunoassay for the determination of IgA antibodies against glycoprotein 2 (GP2) isoform 1 in human serum. The Anti-GP2 Iso 1 IgA is intended as an aid in the ...
MEDIPAN GmbH
... Rapid Test is a sandwich lateral flow chromatographic immunoassay for the qualitative detection of antibodies (IgG, IgM, and IgA) anti-Hepatitis C Virus (HCV) in human serum, plasma or whole blood. It is intended to be used as a screening ...
Specificity: 88, 95 %
Sensitivity: 100, 96 %
... M.pneumoniae IgG, IgA and IgM EIA kits provide accurate results by using highly specific antigen: P1 protein The kits come with ready-to-use, well sufficient reagents ...
Result display time: 15 min - 20 min
Specificity: 98.9, 96, 92.5, 91.6 %
Sensitivity: 97.1, 98, 93.7 %
... Detection of IgG, IgM and IgA Antibodies in Human Whole blood, Serum, Plasma Specimen SARS-CoV-2 IgM-IgG-IgA Combined Antibody Rapid Test Kit is a lateral flow chromatographic immunoassay ...
Jiangsu Mole Bioscience
... to prevent irreversible joint destruction. AESKU® Rheumatology line offers a complete panel of routine and research usage kits, including more than 40 different parameters. ...
AESKU.GROUP
Result display time: 30 min
Specificity: 96 % - 97 %
Sensitivity: 96 % - 100 %
... method for the semiquantitative determination of IgG and IgA antibodies alpha gliadin in human serum, using a disposable device applied on the Chorus and Chorus TRIO instruments. The test is based on ...
... Anti-Tissue Transglutaminase IgA Regulatory Status (USA):510(k) Cleared Discipline:Autoimmune ...
Result display time: 120 min
... The kit allows 96 tests, including controls in a split microtiter plate with color-coded strips and breakable wells. Advantages: The total assay time is about 2 hours. High sensitivity and specificity ...
TestLine Clinical Diagnostics
AID Immunoblots are based on Westernblot method and work with electrophoretic separated protein mixes. Unlike lineblots with recombinant protein, AID Immunoblot are produced with total cell lysates of bacteria or viruses. Benefit of this classical method ...
Result display time: 90 min
Specificity: 99.7 %
Sensitivity: 100 %
... Makes lab setup easy when ELISA readers and washers are utilized for a complete testing solution. Performance An internal study has demonstrated that the OPTI SARS-CoV-2 Total Antibody Test is an extremely sensitive ...
Result display time: 90 min
... ELISA kit for the qualitative and semiquantitative detection of IgA antibodies to Chlamydia trachomatis Characteristic: Number of analyzes — 96 analyzes Shelf life — 12 months Storage conditions ...
Equi
... Package Specifications:R1:1×24mL, R2:1×8mL; R1:2×36mL, R2:1×24mL; ...
... The SARS-CoV-2 (COVID-19) IgA ELISA is intended for the qualitative determination of IgA class antibodies against SARS-CoV-2 in human serum or plasma (citrate, heparin) to support the diagnosis of COVID-19 ...
Result display time: 150 min
... Total Ab ELISA is an Enzyme-Linked Immunosorbent Assay (ELISA) intended for the qualitative detection of total antibodies (IgM/IgA/IgG) to SARS-CoV-2 in human serum and plasma. OVERVIEW SGT Anti-SARS-CoV-2 Total Ab ELISA ...
... the result of MAR IgG test is abnormal, the additional test of MAR IgA is then required. The abnormal result of MAR test would be probably diagnosed as immunologic ...
Result display time: 30 s - 300 s
... GLUTEN intolerance rapid test as an immunochromatographic rapid test detects the presence of anti-tTG IgA antibodies in whole blood. Observe the test results immediately within 5 minutes, ...
Result display time: 90 min
... Biomerica's Transglutaminase IgA ELISA is a 1.5 hour quantitative test for the presence of transglutaminase IgA antibodies in human serum. Celiac disease (CD) or gluten-sensitive enteropathy ...
Result display time: 10 min
Specificity: 99 %
Sensitivity: 85 %
... important at this point. INTENDED USE Turklab’s Tuberculosis Test is a serological and rapid immu- nochromatographic assay for the qualitative detection of antibodies (Isotypes of IgG, IgM and IgA) generated against ...
Turklab Tibbi Malzemeler San. Tic. A.S.
the best suppliers
Subscribe to our newsletter
Receive monthly updates on this section.
Please refer to our Privacy Policy for details on how MedicalExpo processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group