Patch monitoring patch FreeStyle Libre 2 Plus
blood glucosehome careclinical

Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical
Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical
Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical - image - 2
Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical - image - 3
Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical - image - 4
Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical - image - 5
Patch monitoring patch - FreeStyle Libre 2 Plus - Abbott Diabetes Care - blood glucose / home care / clinical - image - 6
Add to favorites
Compare this product

Characteristics

Configuration
patch
Measured parameter
blood glucose
Applications
home care, clinical
Patient condition
for diabetes
Options and accessories
wireless, Bluetooth, with patient data management system, with analysis software, with software
Other characteristics
easy-to-use, non-invasive, smartphone-based, ambulatory, continuous, with data interpretation

Description

Overview
The FreeStyle Libre 2 Plus sensor delivers automatic glucose readings every minute and is designed as a discreet, easy-to-apply continuous glucose monitoring (CGM) sensor with up to 15 days of wear. It is intended to support patients and healthcare professionals in routine glucose monitoring and management.

Key benefits
  • Discreet 15-day sensor — easy to apply and comfortable to wear for up to 15 days.
  • Real-time glucose readings — automatic readings available every minute.
  • No fingersticks required in normal use — fingerstick tests are required if alarms/readings do not match symptoms or when prompted during the first 12 hours after application.
  • Proven 15-day accuracy — validated in manufacturer-cited studies to support clinical glucose decisions.
  • Affordability considerations — positioned to reduce out-of-pocket cost for many patients depending on payer coverage.
  • Clinical outcomes — studies report meaningful A1C reductions and improved glycemic management in published trials.


Customizable glucose alarms
The system supports configurable real-time alarms to match clinical and patient needs:
  • Alarms trigger when readings cross user-defined high/low thresholds.
  • Alarms can be silenced for up to 6 hours (silent mode); visual and vibratory notifications may still appear depending on device/phone settings.
  • Alarm notifications are received when alarm settings are enabled and the sensor is within approximately 20 feet (unobstructed) of the reading device.


Integration and data management
  • Authorized integrations with certain Automated Insulin Delivery (AID) partners are available (for example, noted integration with Omnipod 5 AID system).
  • LibreView data management and reporting enable access to current and historical glucose data to support treatment decisions and clinical workflows (software is an aid and not a substitute for professional medical advice).


Use and safety notes
  • Warm-up period: sensor requires 1 hour after application before glucose readings are available.
  • Readings may be unavailable if the sensor is too hot or too cold, if an error or "LO"/"HI" message appears, or when no current reading is obtainable.
  • Fingerstick measurements are required if symptoms do not match sensor readings, during the first 12 hours when prompted, or as otherwise indicated for treatment decisions.
  • Water resistance: sensor is water-resistant to approximately 1 meter (3 feet) for up to 30 minutes; do not immerse longer than 30 minutes.
  • Coverage and out-of-pocket costs vary by insurance and patient; payer criteria may apply.


Regulatory / age information
Indications and age clearances may vary by sensor and system version. Refer to local regulatory status and device labeling for specific age indications (examples: Libre 2 and Libre 2 Plus clearances noted for different pediatric age groups in some jurisdictions).

Clinical and study references
Manufacturer-cited studies, randomized trials, pediatric studies and meta-analyses are referenced to support claims on accuracy and clinical outcomes; consult cited literature and vendor documentation for details.

Technical specifications
  • Wear time: up to 15 days per sensor.
  • Glucose reading frequency: automatic readings every minute.
  • Warm-up period: 1 hour after application.
  • Alarm functionality: customizable high/low alarms; alarms can be silenced up to 6 hours; notifications require sensor within ~20 feet of reading device and alarms enabled.
  • Accuracy: manufacturer-documented 15-day accuracy per cited studies and device manual.
  • Water resistance: up to 1 meter (3 feet) for up to 30 minutes (do not immerse longer than 30 minutes).
  • Pediatric clearance: age indications vary by sensor/system version; check local labeling.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.