video corpo

Sterilization service sterilizer AD7 Prima UP
clinicalsteambenchtop

Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop
Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop
Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop - image - 2
Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop - image - 3
Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop - image - 4
Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop - image - 5
Sterilization service sterilizer - AD7 Prima UP - APOZA Enterprise CO., LTD. - clinical / steam / benchtop - image - 6
Add to favorites
Compare this product

Characteristics

Applications
clinical, for sterilization services
Sterilization procedure
steam
Configuration
benchtop, built-in
Function
automatic, programmable, microprocessor-controlled, with vacuum cycle
Options
with dryer
Capacity

22 l
(5.81 gal)

Temperature range

134 °C
(273.2 °F)

Sterilization cycle time

4 min

Width

50 cm
(19.69 in)

Height

45 mm
(1.8 in)

Description

Summary
Complete sterilization cycles with controlled drying and integrated data export. Includes USB port and built-in thermal printer.

Highlights
  • Data logger + USB port for parameter export (supports up to 32GB)
  • Built-in thermal printer for cycle records
  • Clear LCD/LED display for status and monitoring
  • Rapid sterilization cycle available (4 min at 134℃)
  • 4 pre-programmed sterilization programs
  • Separated dual water tanks (clean and used)
  • Pre-vacuum (vacuum) autoclave variant
  • 6 safety mechanisms


Details
The NewClave Autohouse AD7 Prima UP is designed for straightforward clinical sterilization workflows. It stores sterilization data in an internal logger with capacity for 21 records; when the limit is reached recording restarts from the first entry. Drying is completed within approximately 30 minutes using an automatic door opening mechanism.

The LED control panel provides one-touch access to four pre-set cycles and straightforward monitoring of time and temperature. An emergency rapid program (Program 1) performs sterilization at 134℃ in about 4 minutes. The unit uses a single-use water system with two separate tanks to prevent cross-contamination between clean and used water. Auto drainage prevents overfilling and eases maintenance.

Technical specifications
  • Model series: AD7 Prima UP
  • Chamber capacity: 22 L
  • Sterilization programs: 4 pre-programmed cycles
  • Rapid sterilization: 4 minutes at 134℃ (emergency program)
  • Drying: approx. 30 minutes with automatic door opening
  • Variants: pre-vacuum (vacuum type) and non-vacuum
  • Data logger: stores up to 21 sterilization records; supports large-capacity USB (32GB)
  • Connectivity: USB port for data export
  • Printer: built-in thermal printer
  • Display: clear LCD/LED control panel
  • Water system: separated dual tanks (clean and used)
  • Drainage: automatic water drainage design
  • Safety: 6 safety mechanisms