Fractionated vacuum sterilizers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Capacity: 23, 17 l
Carrying capacity: 6 kg
Sterilization cycle time: 15 min
... resource-saving sterilisation of your instruments. Top Characteristics The new MELAG Vacuclave 123 autoclave – love the quality and the price: Powerful class B vacuum process: Reliable sterilization of up to ...
MELAG
Capacity: 18 l
Carrying capacity: 9, 2 kg
Width: 46 cm
... Quick-Program in only 20 minutes; unwrapped instruments are sterilized in only 10 minutes (inc. fractionated pre- vacuum and drying) High loading capacity of 9 kg: the autoclave can now accommodate ...
MELAG
Capacity: 18 l
Carrying capacity: 9, 2 kg
Width: 46 cm
... Quick-Program in only 20 minutes; unwrapped instruments are sterilized in only 10 minutes (inc. fractionated pre- vacuum and drying) High loading capacity of 9 kg: the autoclave can now accommodate ...
MELAG
Capacity: 50 l - 100 l
Temperature range: 105 °C - 134 °C
Width: 70 cm
... Introduction
The vertical pulse
vacuum
autoclave uses steam as the sterilizing medium and applies repeated
vacuum and steam fill cycles to achieve controlled
vacuum, pressure ...
Capacity: 18 l - 23 l
Temperature range: 105 °C - 134 °C
Sterilization cycle time: 0 min - 99 min
... Introduction
The pulse-
vacuum Class B tabletop
autoclave performs repeated
vacuum pulses and steam injections to remove air and allow saturated steam to reach the set pressure and temperature, ...
Capacity: 200, 300, 150, 360 l
Temperature range: 105 °C - 134 °C
Sterilization cycle time: 0 min - 99 min
... Introduction
The pulse
vacuum
autoclave repeatedly applies
vacuum and injects steam into the sterilization chamber until the target
vacuum degree is reached, then fills saturated ...
Capacity: 25 l - 200 l
Temperature range: 140 °C - 150 °C
Depth: 315 mm - 1,000 mm
... br>Load type | Gravitation | Simple pre- vacuum | Pulsed excess pressure | Fractionated pre- vacuum | Conventional cooling | Rapid cooling with support pressure | Surface drying without vacuum ...
Capacity: 50 l
Temperature range: 116 °C - 134 °C
Sterilization cycle time: 4 min - 120 min
... Product overview
Labotemp Vertical
Autoclave VEA-11 is a fully automatic
autoclave designed for reliable steam sterilization of laboratory instruments, surgical tools, culture media, glassware, dressings, and ...
Labotemp Systems
Capacity: 50 l - 50 l
Temperature range: 0 °C - 134 °C
Sterilization cycle time: 0 min - 99 min
... Overview
Labotemp Vertical Pulse
Vacuum
Sterilizer LPS-106 is a compact pulse
vacuum
autoclave engineered for efficient steam sterilization in hospitals, clinics, research laboratories, ...
Labotemp Systems
Capacity: 360 l
Temperature range: 116 °C - 139 °C
Width: 116 cm
... Product overview
Labotemp Pulse
Vacuum
Sterilizer LPS-105 is a 360 L pulse
vacuum
autoclave engineered for steam sterilization in hospitals, central sterile supply departments ...
Labotemp Systems
Capacity: 18 l - 55 l
Temperature range: 121 °C - 134 °C
Sterilization cycle time: 3 min - 15 min
... Description
- Class B desktop flash autoclave for rapid sterilization of medical and dental instruments
- Pre‑vacuum microprocessor-controlled pump
- Capacity: 18–23 L
- Graphical LCD
Capacity: 22, 17 l
Temperature range: 134 °C
Sterilization cycle time: 4 min
... Product overviewBrand: APOZAModel: Type B 1VProduct type: Class B vacuum autoclave for medical and instrument sterilizationKey featuresClass B ( vacuum) sterilization suitable for packaged instruments ...
Capacity: 17, 22 l
Temperature range: 134 °C
Sterilization cycle time: 4 min - 20 min
... Overview
NewClave Autohouse Type-B (1V) is a Class B
autoclave designed for medical and dental sterilization. It uses
fractionated pre-
vacuum steam sterilization with post-
vacuum ...
Capacity: 80 l - 150 l
... which require intensive subsequent drying. Integrated steam generator Vacuum pump set Exhaust air filtration EAF Complete Lab Fully equipped laboratory autoclave for operation in the level S2 lab. ...
Capacity: 104 l
Temperature range: 105 °C - 136 °C
Width: 890 mm
... production of steam. Maintenance-free diaphragm-type powerful vacuum pump. Fractionated pre- vacuum to eliminate all air bubbles and achieve successful steam penetration. Fractionated ...
Nüve
Capacity: 150 l
Temperature range: 105 °C - 134 °C
Sterilization cycle time: 20 min - 60 min
... Vertical
fractionated-
vacuum autoclave designed for sterilization in pharmaceutical and medical environments; integrates drying and supports fractional
vacuum cycles.
Category ...
JP Selecta
Capacity: 50 l - 169 l
Temperature range: 105 °C - 140 °C
Height: 1,110, 1,060, 1,310 mm
... cloud-based connectivity that complies with FDA, GMP, and GLP standards Vertical laboratory autoclaves with super-drying system The TLV-PD Series vertical autoclaves with super-drying system using a heated jacket ...
RAYPA
Capacity: 16 l
... cost-effective, its' out-standing performance cornes from having more than 30 years of high quality autoclave design experience. PodiaClave+ is a Class B sterilizer available in 16 litre capacity and is fully supported ...
Capacity: 4.5 l
Carrying capacity: 63 kg
Temperature range: 138 °C
... display is very modern and striking. -A real innovation is the new recharging attachment inserted flush to the front of the autoclave front panel. Europa B Evo is a last generation autoclave, developped with the collaboration of ...
Tecno-Gaz
Capacity: 17 l - 21 l
Temperature range: 134 °C
... Fractionated vacuum system 17L or 21L chamber capacity Intelligent closed door drying Integrated datalogger Industry leading cycle times Single use Pull’n Push water system 2 Year warranty The ...
Capacity: 24 l
Carrying capacity: 2.5 kg - 7 kg
Temperature range: 121 °C - 134 °C
... the Phoenix Blu autoclave you decide how long the cycles last. Enough with the preset cycles, for each sterilization cycle you can select the drying time at will (1-5-10 min.) USB PORT & BUILT-IN PRINTER The Phoenix Blu autoclave ...
Medical Trading S.R.L.
Capacity: 22 l
Carrying capacity: 5 kg
Sterilization cycle time: 25 min
... 44-B works with a fractionated pre- vacuum and satisfies the requirements to “Class B”- autoclaves of the European standard EN 13060. The deep vacuum is created by a very high performance ...
... Type B Fractionated Vacuum Autoclave A fractionated vacuum autoclave meeting European Standards for B cycles, vacuums to 0.80bar 3times ...
Capacity: 54 l - 697 l
Temperature range: 100 °C - 134 °C
... Quality Designed and manufactured according to ASME (American Society of Mechanical Engineers) and ABNT (Brazilian Association of Technical Standards) standards. Quality system in compliance with ISO 9001:2000 standard. Internal and external chambers ...
Ortosintese
Capacity: 19 l - 23 l
Carrying capacity: 47 kg - 51 kg
Temperature range: 115 °C - 134 °C
... Main feature: 01. Class B,Pre & post vacuum 02. Display and control by high resolution 5 " color touch screen 03. Sterilization temperatures 115℃, 121 ℃ and 134 ℃ 04. 4 preprogrammed cycles ,1- customized programmed ...
Capacity: 40 l
Width: 620 mm
Height: 489 mm
... powerful vacuum sterilization used for tubal, wrapped, unwrapped and optional liquid sterilization. Vacuum based sterilization is used for instruments with hollow cavities, such as handpieces, suction tubes and syringes. ...
Sturdy Industrial
Capacity: 18 l
Height: 390 mm
Depth: 580 mm
... Advanced software with multilingual display options. Fractionated vacuum system removes air completely and ensures more effective steam penetration. Two test programs: Helix/Bowie & Dick test and Vacuum ...
TAU STERIL
Capacity: 18 l - 45 l
Temperature range: 134 °C - 139 °C
Width: 50.5 cm - 87 cm
... over-pressure, low water level, anti-dry burn, door lock
Capacity: 8 l - 23 l
Temperature range: 134 °C - 139 °C
Width: 44.5 cm - 48 cm
... pressure protection, low water level protection, anti dry burning, safety door lock
laboratory sterilizerCG series
Capacity: 120 l - 5,000 l
Temperature range: max 139.0 °C
... air on temperature through pulse vacuum. Vacuum dehumidification combined with jacket heating is used to dry articles. Finally, empty the sterile air to achieve pressure balance. Therefore, it has two functions of vacuum ...