1. Dental
  2. Dental practice
  3. Dental sterilizer
  4. APOZA Enterprise CO., LTD.
video corpo

Medical sterilizer NewClave Type-B (1V)
dentalsteambenchtop

Medical sterilizer - NewClave Type-B (1V) - APOZA Enterprise CO., LTD. - dental / steam / benchtop
Medical sterilizer - NewClave Type-B (1V) - APOZA Enterprise CO., LTD. - dental / steam / benchtop
Medical sterilizer - NewClave Type-B (1V) - APOZA Enterprise CO., LTD. - dental / steam / benchtop - image - 2
Medical sterilizer - NewClave Type-B (1V) - APOZA Enterprise CO., LTD. - dental / steam / benchtop - image - 3
Medical sterilizer - NewClave Type-B (1V) - APOZA Enterprise CO., LTD. - dental / steam / benchtop - image - 4
Medical sterilizer - NewClave Type-B (1V) - APOZA Enterprise CO., LTD. - dental / steam / benchtop - image - 5
Add to favorites
Compare this product

Characteristics

Applications
medical, dental
Sterilization procedure
steam
Configuration
benchtop
Function
automatic, programmable, with vacuum cycle, fractionated vacuum
Sterilization chamber material
stainless steel
Options
with dryer
Capacity

17 l, 22 l
(4.49 gal, 5.81 gal)

Temperature range

134 °C
(273.2 °F)

Sterilization cycle time

Min.: 4 min

Max.: 20 min

Width

66 cm
(25.98 in)

Height

45 cm
(17.7 in)

Description

Overview
NewClave Autohouse Type-B (1V) is a Class B autoclave designed for medical and dental sterilization. It uses fractionated pre-vacuum steam sterilization with post-vacuum drying to achieve effective sterilization for wrapped and unwrapped, solid, hollow and porous instruments. Available in 17 L and 22 L chamber capacities.

Key features
  • Four one-touch pre-programmed sterilization cycles selectable from an intuitive control panel
  • Fractionated pre-vacuum technology with post-vacuum drying for thorough steam penetration and low residual moisture
  • Speedy program: 4 minutes at 134°C plus 15 minutes drying (≈20 minutes total) for urgent loads
  • Separate clean and used water tanks to maintain sanitation and prevent cross-contamination
  • Automatic water drainage system for safe, hassle-free operation
  • Seven integrated safety mechanisms to protect operator and load
  • High-quality stainless steel chamber for corrosion resistance and durability


Compliance and standards
Designed to meet EN 13060 requirements for Class B small steam sterilizers and tested against EN 867-5. Residual moisture targets: ≤ 0.2% for instruments and ≤ 1.0% for textiles.

Operation & programs
The control interface provides clear one-click selection of time, temperature and safety-monitored cycles. The speedy cycle is optimized for urgent clinical needs, while other programs cover standard wrapped and porous loads.

Water & sanitation
Operates with a single-use water system that separates clean and used water in two dedicated tanks. The design prevents overfilling and simplifies maintenance with an automatic drainage function.

Safety & construction
Equipped with seven safety measures including pressure and temperature interlocks and an emergency release procedure. The chamber is manufactured from high-grade stainless steel for reliable long-term use.

Technical specifications
  • Model: Autohouse Type-B (1V)
  • Product line: NewClave
  • Capacities: 17 L / 22 L
  • Class: EN 13060 Class B
  • Standards: EN 13060, EN 867-5
  • Sterilization method: Fractionated pre-vacuum steam sterilization with post-vacuum drying
  • Speedy cycle: 4 min at 134°C + 15 min drying (≈20 min total)
  • Pre-programmed cycles: 4 (one-click selection)
  • Water system: Two separated tanks (clean and used), single-use water system
  • Auto water drainage: Yes
  • Residual moisture: ≤ 0.2% (instruments), ≤ 1.0% (textiles)
  • Safety mechanisms: 7 integrated safety measures
  • Chamber material: High-quality stainless steel