OverviewThe DxH 690T is a benchtop hematology analyzer designed for mid-volume clinical laboratories. It delivers automated CBC with differential, advanced cellular characterization and built-in data handling in a compact tabletop configuration.
Quality That Counts- Near-native-state characterization for robust RBC, PLT and WBC differentials
- High first-run confidence to reduce reruns and reflex testing
- Intelligent smear optimization to improve slide interpretation consistency
Productivity That Liberates- Predictable hematology workflows for simplified workload planning
- Reliable flagging to focus technologist attention where required
Savings That Empower- Customizable automated QA/QC with daily reminders and remote support
- Fewer reflex tests to save time and reagent costs
- Reduced hematology reagent consumption
- Reallocation of up to 200 minutes daily previously used for reflex testing
- Lower overheads (electricity, maintenance)
Monocyte Distribution Width (MDW)MDW is a regulatory-cleared hematological biomarker available on DxH 690T (and DxH 900). Reported automatically as part of routine CBC-diff with the Early Sepsis Indicator application, MDW assists in identifying adults at risk of severe infection or sepsis in the Emergency Department.
Technical specifications- Methodology: Enhanced Coulter Principle, VCS 360 with DataFusion
- Parameters: CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV. Differential: NE%, LY%, MO%, EO%, BA%, NRBC%, NE#, LY#, MO#, EO#, BA#, NRBC#. MDW (when enabled). Retic: RET, RET#, MRV, IRF. Body Fluids (CSF, serous, synovial): RBC, TNC.
- Throughput (tests per hour): Up to 100 samples/hour
- Sample volumes: Whole blood: 165 μL aspiration. Predilute: 50 μL whole blood into 200 μL diluent
- Analytical measuring ranges — Whole blood (CBC): WBC (x10^3 cells/μL): 0.050–400.000; RBC (x10^6 cells/μL): 0.005–8.500; HGB (g/dL): 0.10–25.50; MCV (fL): 50.00–150.00; RDW (%): 10.00–40.00; RDW-SD (fL): 15.00–150.00; PLT (x10^3 cells/μL): 3.0–3000.0; MPV (fL): 5.00–25.00
- Body fluids (analytical ranges): TNC (cells/mm^3): 20–89,000; RBC (cells/mm^3): 1,000–6,200,000
- Data management: Up to 50,000 patient results with histograms, scatter plots and demographics; 100,000 results with graphics for power computer
- Quality assurance: QC with Levy-Jennings graph; XB/XM moving averages; daily check; intelligent quality monitoring; MRV, IRF; customizable calibration and QC reminders; auto-export of QC
- Acoustic noise level: ≤ 60 dBa
- EMC / interference immunity: Complies with EN 61326-1 and EN 61326-2-6 for product-level EMC and IVD devices
- Power consumption: DxH 690T SPM: 520 W (1775 BTU/h); Monitor: 35 W (120 BTU/h); DxH Power Computer: 160 W (546 BTU/h)
- Dimensions & weight: Width: 76.2 cm; Height: 90.17 cm (cover closed) / 113.03 cm (cover open); Depth: 83.82 cm (including removable back panel) / 80.00 cm (excluding panel); Weight: ~141.97 kg (with monitor) / ~136.98 kg (without monitor)
- Additional clearance: 15.2 cm per side for troubleshooting; 3.8 cm behind for cooling
- Maintenance & service: Preventative maintenance schedule with customer care visits; minimum downtime: 30 minutes daily in cleaner with automatic checks
- Support: Onboard IFU and instructional videos, automated QC/calibration reminders, PROService
- Research use only (RUO) parameters: BFM, BFM#, BFP#, EGC, EGC#, HLR, HLR#, LHD, MAF, MSCV, PCT, PDW, RDWR, RDWR-SD, RSF, UGC, UGC#, UWROP, WDOP, WNOP, WROP, CPD (refer to RUO addendum). RUO parameters not for IVD use.