CO2 laboratory incubator CB 56
hot aircarbon dioxidefor scientific research

CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research - image - 2
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research - image - 3
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research - image - 4
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research - image - 5
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research - image - 6
CO2 laboratory incubator - CB 56 - BINDER GmbH - hot air / carbon dioxide / for scientific research - image - 7
Add to favorites
Compare this product

Characteristics

Type
hot air, CO2, carbon dioxide
Applications
for cell cultures, for scientific research, medical
Configuration
benchtop, not specified
Chamber material
stainless steel
Number of doors
1-door
Other characteristics
temperature-control, with humidifier, with decontamination system, infrared
Temperature range

50 °C
(122 °F)

Capacity

53 l
(14 gal)

Description

Product description
The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories.

Benefits
  • Safe – cell cultures receive maximum protection against contamination
  • Reliable – constant well-being conditions for the cells
  • Smart – simple routine cleaning and convenient operation
  • Economical – efficient operation without consumables

Important characteristics
  • Optimized double-pan humidification system with condensation protection
  • Tried-and-tested anti-contamination concept with 180°C hot air sterilization
  • Hot-air sterilizable CO₂ sensor with single-beam infrared technology
  • Seamless inner chamber made of stainless steel with flanges as shelf support system
  • Fanless interior with Venturi CO₂ gas mixing nozzle
  • Intuitive touchscreen controller
  • Internal data recording, can be read out in open format via USB interface
  • Fault diagnosis system with visual and acoustic alarm
  • Interfaces: Ethernet, USB, zero-voltage alarm contact
  • Fail-safe CO₂ system for protecting the pH of cell cultures

Technical specifications (key values)
  • Article Number (examples): 9040-0197 / 9040-0198
  • Designation (examples): CB056-230V / CB056UL-120V
  • Option model: Standard
  • Temperature range: +4 °C above ambient temperature to 50 °C
  • Temperature uniformity at 37 °C: 0.3 ± K
  • Temperature fluctuation at 37 °C: 0.1 ± K
  • Recovery time after door was opened for 30 s at 37 °C: 5 min
  • Humidity range: 90 ...95 % RH
  • CO₂ range: 0 ...20 Vol.-% CO₂
  • CO₂ measuring technology: IR (infrared)
  • CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂: 5 min
  • Rated voltage (examples): 200...230 V or 100...120 V
  • Power frequency: 50/60 Hz
  • Nominal power: 0,8 kW
  • Unit fuse: 10,0 A (200...230 V) / 16,0 A (100...120 V)
  • Phase (Nominal voltage): 1~
  • Interior volume: 53 L
  • Net weight (unit empty): 53 kg
  • Load per rack: 10 kg
  • Permitted load: 30 kg
  • Wall clearance back: 100 mm
  • Wall clearance sidewise: 50 mm
  • Housing width (net): 528 mm
  • Housing height (net): 674 mm
  • Housing depth (net): 545 mm
  • Interior width: 400 mm
  • Interior height: 400 mm
  • Interior depth: 330 mm
  • Inner doors: 1
  • Unit doors: 1
  • Number of shelves (std./max.): 2 / 3
  • Sound-pressure level: 41 dB(A)
  • Energy consumption at 37 °C: 45 Wh/h

Caractéristiques / spécifications techniques
  • Model name: CB 56
  • Brand: BINDER
  • Article numbers: 9040-0197 (example) / 9040-0198 (example)
  • Designation (examples): CB056-230V / CB056UL-120V
  • Option model: Standard
  • Temperature range: +4 °C above ambient to 50 °C
  • Temperature uniformity at 37 °C: 0.3 ± K
  • Temperature fluctuation at 37 °C: 0.1 ± K
  • Recovery time (temp) after 30 s door opening at 37 °C: 5 min
  • Humidity range: 90–95 % RH
  • CO₂ range: 0–20 Vol.-% CO₂
  • CO₂ measurement: IR single-beam infrared (hot-air sterilizable)
  • CO₂ recovery time after 30 s door opening at 5 % CO₂: 5 min
  • Interfaces: Ethernet, USB, zero-voltage alarm contact
  • Rated voltage options: 200...230 V or 100...120 V
  • Power frequency: 50/60 Hz
  • Nominal power: 0.8 kW
  • Unit fuse: 10.0 A (200...230 V) / 16.0 A (100...120 V)
  • Phase: single-phase (1~)
  • Interior volume: 53 L
  • Net weight (empty): 53 kg
  • Load per rack: 10 kg
  • Permitted load (total): 30 kg
  • Wall clearance (back): 100 mm
  • Wall clearance (sidewise): 50 mm
  • Net width: 528 mm
  • Net height: 674 mm
  • Net depth: 545 mm
  • Interior width: 400 mm; interior height: 400 mm; interior depth: 330 mm
  • Inner doors / unit doors: 1 / 1
  • Number of shelves (std./max.): 2 / 3
  • Sound-pressure level: 41 dB(A)
  • Energy consumption at 37 °C: 45 Wh/h

VIDEO

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Lab-Supply Dresden
Lab-Supply Dresden

8-08 Sep 2026 Dresden (Germany)

  • More information
    Lab-Supply Hamburg
    Lab-Supply Hamburg

    3-03 Nov 2026 Hamburg (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.