Product descriptionThe durable and affordable CB-S series incubators are designed for routine cell cultivation and cell production workflows in laboratories and academic environments. The units provide contamination protection through automatic 180 °C hot-air sterilization and ensure stable pH control via drift-free infrared CO₂ measurement in real time.
Benefits- Safe – maximum protection against contamination for cell cultures
- Reliable – constant, controlled environment for reproducible results
- Smart – straightforward routine cleaning and easy operation
- Economical – efficient operation without disposable consumables
Important characteristics- Humidification system with condensation protection
- Proven anti-contamination concept with 180 °C hot-air sterilization (auto-sterilization)
- CO₂ sensor using infrared technology (drift-free IR measurement)
- Seamless stainless-steel inner chamber with safety inner glass door
- CO₂ gas mixing jet with Venturi effect
- PID controller with clear LCD display
- Internal data logger; measured values exportable in open format via USB
- Troubleshooting system with visual and acoustic alarms
- Interfaces: Ethernet, USB, potential-free alarm contact
DataArticle Number: 9040-0223 | 9040-0224
Designation: CBS260-230V | CBS260UL-120V
Option model: Standard
Performance Data - TemperatureArticle Number: 9040-0223 | 9040-0224
Temperature range: +6 °C above ambient temperature to 50 °C
Temperature uniformity at 37°C: 0.4 ± K
Temperature fluctuation at 37°C: 0.1 ± K
Recovery time after door was opened for 30 s at 37°C: 8 min
Performance Data - ClimateArticle Number: 9040-0223 | 9040-0224
Humidity range: 90 ...95 % RH
Gas DataArticle Number: 9040-0223 | 9040-0224
CO2 range: 0 ...20 Vol.-% CO2
CO2 measuring technology: IR
CO2 recovery time after door was opened for 30 s at 5 vol. % CO2: 5 min
Electrical dataArticle Number: 9040-0223 | 9040-0224
Rated Voltage: 200...230 V (9040-0223) | 100...120 V (9040-0224)
Power frequency: 50/60 Hz
Nominal power: 1,5 kW
Unit fuse: 10,0 A (230 V) | 16,0 A (120 V)
Phase (Nominal voltage): 1~
Dimensions and weightsArticle Number: 9040-0223 | 9040-0224
Interior volume: 267 L
Net weight of the unit (empty): 116 kg
Load per rack: 10 kg
Permitted load: 40 kg
Wall clearance back: 100 mm
Wall clearance sidewise: 50 mm
Housing dimensions (not incl. fittings and connections)Width net: 740 mm
Height net: 1,020 mm
Depth net: 785 mm
Internal DimensionsInterior width: 620 mm
Interior height: 750 mm
Interior depth: 575 mm
Inner doors: 1
Unit doors: 1
Environment-specific dataSound-pressure level: 41 dB(A)
Energy consumption at 37°C: 55 Wh/h
FixturesNumber of shelves (std./max.): 2/8
Options, accessories & services (selection)- Accessories: stacking adapter, stacking frame, base, stainless steel perforated shelves
- Analog output 4-20 mA for temperature and CO2 (8012-1839)
- Access ports with silicone plug (30 mm) - positions: back (8012-2729), left (8012-2730), right (8012-2731)
- Gas cylinder connection set for CO2 (8012-0014)
- Calibration certificates and calibration services (multiple options)
- Maintenance contracts (BRONZE / SILVER / GOLD) and commissioning services
Technical characteristics / specifications- Model: CB-S 260
- Article numbers: 9040-0223 (200...230 V), 9040-0224 (100...120 V)
- Interior volume: 267 L
- Temperature range: +6 °C above ambient to 50 °C
- Temperature uniformity at 37°C: 0.4 ± K; fluctuation: 0.1 ± K
- CO2 range: 0 ...20 Vol.-% CO2; measuring tech: IR (infrared)
- Humidity control: condensation protection; humidification with water pan
- Hot air sterilization: +180°C auto-sterilization
- Controller: PID with LCD (clear) and internal data logger (USB export)
- Interfaces: Ethernet, USB, potential-free alarm contact
- Net weight (empty): 116 kg; nominal power: 1.5 kW
- Shelves: standard 2, max. 8; load per rack: 10 kg; permitted total load: 40 kg
- Sound level: 41 dB(A); energy consumption at 37°C: 55 Wh/h
- External dimensions (W×H×D): 740 × 1,020 × 785 mm (net)