Product descriptionThe CB-S 170 CO₂ incubator is a durable, economical unit intended for routine cell culture workflows in cell production and academic laboratories. Contamination is mitigated by automatic 180°C hot-air sterilization; CO₂ control is maintained by a drift-free infrared (IR) CO₂ sensor with real-time measurement.
Benefits- Safe – maximum protection against contamination for cell cultures
- Reliable – stable environmental conditions (temperature, humidity, CO₂)
- Smart – straightforward routine cleaning and user-friendly operation
- Economical – efficient operation without disposable consumables
Important characteristics- Humidification system with condensation protection
- Proven anti-contamination concept with 180°C hot-air sterilization
- Drift-free IR CO₂ sensor for real-time CO₂ measurement
- Seamless stainless steel inner chamber
- CO₂ mixing jet using Venturi effect
- PID controller with clear LCD display
- Internal data logger; measured values exportable in open format via USB
- Troubleshooting system with visual and acoustic alarms
- Interfaces: Ethernet, USB, potential-free alarm contact
Technical specifications (selected)Article Number: 9040-0219 | 9040-0220 | 9040-0221 | 9040-0222
Designation: CBS170-230V | CBS170-230V-L | CBS170UL-120V | CBS170UL-120V-L
Option model: Standard / left-hand hinge variants
Temperature range: +6 °C above ambient to 50 °C
Temperature uniformity at 37 °C: 0.3 ± K
Temperature fluctuation at 37 °C: 0.1 ± K
Recovery time after 30 s door open at 37 °C: 6 min
Humidity range: 90–95 % RH
CO₂ range: 0–20 Vol.-% CO₂
CO₂ measuring technology: IR (infrared); CO₂ recovery time after 30 s door open at 5 Vol.-% CO₂: 5 min
Rated voltage: 200–230 V (some variants 100–120 V); 50/60 Hz
Nominal power: 1.3 kW
Unit fuse: 10.0 A (200–230 V) / 16.0 A (100–120 V)
Phase: 1~
Interior volume: 170 L
Net weight (empty): 96 kg
Load per rack: 10 kg | Permitted total load: 30 kg
Wall clearance back/side: 100 mm / 50 mm
Dimensions (net): W 680 mm × H 870 mm × D 715 mm
Interior dimensions (W × H × D): 560 mm × 600 mm × 505 mm
Number of doors (inner/outer): 1 / 1
Shelves (std./max.): 2 / 6
Sound-pressure level: 41 dB(A)
Energy consumption at 37 °C: 45 Wh/h
Accessories & Services (examples)- Accessories: stacking frame/adapter, base, perforated stainless steel shelves
- Calibration certificates (temperature and CO₂) and extended calibration options
- Analog outputs 4–20 mA for temperature and CO₂
- Access ports (left/right/back), door lock, copper interior fittings
- Software: APT-COM™ management editions (BASIC / PROFESSIONAL / GLP)
- Services: maintenance contracts, IQ/OQ and qualification services, commissioning, warranty extension
Characteristics / technical specifications- Model: CB-S 170
- Volume: 170 L
- Temperature range: +6 °C above ambient to 50 °C
- CO₂ range: 0–20 Vol.-% CO₂
- Humidity control: 90–95 % RH (condensation-protected)
- Sterilization: automatic 180 °C hot-air sterilization
- CO₂ sensor: infrared (IR), drift-free real-time measurement
- Controller: PID with clear LCD; internal data logger with USB export (open format)
- Interfaces: Ethernet, USB, potential-free alarm contact
- Dimensions (net): 680 × 870 × 715 mm; interior: 560 × 600 × 505 mm
- Weight (empty): 96 kg
- Power: 1.3 kW; voltage variants 200–230 V or 100–120 V; 50/60 Hz
- Shelves: 2 standard, up to 6; load per shelf 10 kg; total permitted load 30 kg
- Noise: 41 dB(A); Consumption at 37 °C: 45 Wh/h