Brushless motor 16X561
for surgical power toolsfor dental handpiecesfor laboratory automation

Brushless motor - 16X561 - Boreasa Technologies Co., Ltd - for surgical power tools / for dental handpieces / for laboratory automation
Brushless motor - 16X561 - Boreasa Technologies Co., Ltd - for surgical power tools / for dental handpieces / for laboratory automation
Add to favorites
Compare this product

Do you want to buy directly? Visit our shop.

Characteristics

Applications
for surgical power tools, medical industry, for dental handpieces, for medical analyzer, for medical ventilators, for medical equipment, for electronic assembly, surgical screwdriver, for surgical equipment, for fastening screwdrivers, for industrial electric grippers, gas detection, for humanoid robot, for thrombolysis device, for infusion pumps, for biopsy system, for contrast injector, for surgical robotics, for exoskeleton, for cosmetic hand tools, for power hand tools, for pruning shears, for diaphragm pump, for laboratory automation
Operational mode
brushless, hall sensor
Current type
DC
Power

120 W
(0 hp)

Diameter

16 mm
(0.63 in)

Description

Specifications (at 25°C): Model: 16X561184 | 16X561245 Voltage supply: 18 V | 24 V No-load speed: 56,620 rpm | 60,280 rpm No-load current: 271 mA | 240 mA Max. continuous torque: 24.61 mNm | 26.05 mNm Max. continuous current: 8.12 A | 6.87 A Nominal speed: 54,214 rpm | 58,002 rpm Nominal torque: 18.61 mNm | 19.78 mNm Nominal current: 7.17 A | 6.08 A Nominal power: 105 W | 120 W Power density: 9.33 W/cm³ | 10.66 W/cm³ Max. efficiency: 91.3 % | 91.6 % Torque constant: 3.03 mNm/A | 3.80 mNm/A Speed constant: 3,152 rpm/V | 2,516 rpm/V Speed torque gradient: 135 rpm/mNm | 121 rpm/mNm Terminal resistance: 0.130 Ω | 0.182 Ω Terminal inductance: 0.0115 mH | 0.0176 mH Thermal data: Ambient working temperature: -40 … 100 °C Max. winding temperature: 155 °C Mechanical data: Mechanical time constant: 1.21 ms Max. speed: 80,000 rpm Ball bearings preload: 2.5 N Max. axial load (dynamic): 2.5 N Max. axial force for press fits (static): 85 N Max. radial load [mm from flange]: 10 N [5] Miscellaneous: Number of poles: 2 Number of phases: 3 Rotor inertia: 0.853 g·cm² Typical noise level [rpm]: 35 dB(A) [50,000 rpm] Weight of motor: 75 g

Catalogs

16X561
16X561
1 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

Medica 2025
Medica 2025

17-20 Nov 2025 Dusseldorf (Germany) Hall 8A - Stand R08

  • More information
    SPS 2025
    SPS 2025

    25-27 Nov 2025 Nuremberg (Germany) Hall 3 - Stand 3-470

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.