Hip isokinetic dynamometer A8 mini5
kneeankleelbow

Hip isokinetic dynamometer - A8 mini5 - Guangzhou Yeecon Medical Equipment Industrial - knee / ankle / elbow
Hip isokinetic dynamometer - A8 mini5 - Guangzhou Yeecon Medical Equipment Industrial - knee / ankle / elbow
Add to favorites
Compare this product

Characteristics

Area of the body
knee, ankle, hip, elbow, shoulder, wrist

Description

Short Description
  • Power head torque setting range: ≥ 0 Nm to 250 Nm
  • Angular velocity adjustment range: ≥ 0.05°/s to 360°/s
  • Minimum output angular velocity: 0.05°/s (1% full-scale error tolerance)
  • Power head shaft rotation angle: ≥ 360°
  • Power supply: AC 220 V, 50 Hz; Rated power: 800 W


Product Introduction
The A8 mini5 integrates isokinetic, isometric and isotonic testing and training with continuous passive motion (CPM), progressive CPM, elastic resistance and proprioceptive modes in a single portable bedside unit. It supports quantitative functional assessment and interactive virtual-scene training, and provides comparative kinematic feedback for clinical rehabilitation of neurological and sports-related injuries. The device supports 22 standard motion patterns across six major joints and enables bedside and clinic-based interventions across early, intermediate and late recovery stages.

Functional Features
  • Seven training modes: isokinetic, isometric, isotonic, CPM, progressive CPM, elastic resistance and proprioceptive training to cover evaluation and full-cycle musculoskeletal rehabilitation workflows.
  • Portable bedside isokinetic unit with compact form factor and unrestricted mobility for bedside early rehabilitation and diverse clinical environments.
  • High-precision power actuator with minimum angular velocity 0.05°/s and 1% full-scale error tolerance for accurate assessment and ultra-early intervention.
  • Continuously adjustable angular velocity and variable torque output enabling concurrent training of agonist and antagonist muscle groups.
  • Interchangeable joint attachments (12) including shoulder, elbow-shoulder, wrist, hip-knee, ankle and steering-wheel accessories to cover more than 20 types of motion testing and training.
  • Built-in IoT data interface for synchronous collection and integration of assessment and training data.


6 Major Joints, 22 Standard Motion Patterns
  • Shoulder abduction / adduction
  • Horizontal shoulder flexion (horizontal adduction) & horizontal abduction
  • PNF D2
  • Shoulder internal rotation / external rotation
  • PNF D1
  • Shoulder flexion / extension
  • Elbow flexion / extension
  • Forearm pronation / supination
  • Wrist radial deviation / ulnar deviation
  • Wrist flexion / extension
  • Seated knee flexion / extension
  • Prone knee flexion / extension
  • Supine knee flexion / extension
  • Hip abduction / adduction
  • Hip internal rotation / external rotation
  • Supine ankle plantarflexion / dorsiflexion
  • Prone ankle plantarflexion / dorsiflexion


Technical Specifications
  • Model: A8 mini5
  • Training modes: isokinetic, isometric, isotonic, CPM, progressive CPM, elastic resistance, proprioceptive training
  • Power head torque setting range: ≥ 0 Nm to 250 Nm
  • Angular velocity adjustment range: ≥ 0.05°/s to 360°/s
  • Minimum output angular velocity: 0.05°/s (1% full-scale error tolerance)
  • Power head shaft rotation angle: ≥ 360°
  • Interchangeable joint attachments: 12 (shoulder, elbow-shoulder, wrist, hip-knee, ankle, steering wheel accessories)
  • Supported joints: shoulder, elbow, wrist, hip, knee, ankle (22 motion patterns)
  • Power supply: AC 220 V, 50 Hz
  • Rated power: 800 W
  • Built-in IoT data interface for synchronous data collection and integration
  • Portable bedside unit for diversified clinical applications and early rehabilitation

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

MEDICA 2026
MEDICA 2026

16-19 Nov 2026 Düsseldorf (Germany) Hall 4 - Stand J18

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.