Product DetailsConcentrator refers to the amount of a substance in a defined space. Concentration is especially used for concentrating or preparing sample in batches in laboratory.
- Used in Drug screening, hormone analysis, liquid phase
- Also known as Laboratory Concentrator
Key Features- Elegant appearance, with elevation operation panel, flowmeter, waterproof button, safe and reliable
- Good compatibility, suitable for test tubes (diameter 10 ~ 29mm), conical flask, centrifuge tube, the sample capacity of 1 ~ 50ml
- Free up and down needle valve tube, independent adjustable controls gas flow at each sample location
- Circular turntable structure, 360-degree rotation, convenient sample support into and out of the water bath, easy to operate
- 12 position, each sample position are numbered, spring tube position
- LED real-time displays temperature and time, water bath
- All use of stainless steel, all components are anti-corrosion and resistant to organic solvents
- When concentrated toxic solvents, the entire system can be placed in a fume hood
- Built-in level sensor, anti-dry protection
- Suitable for a variety of test tubes, so that the gas needle is aimed at the center of the test tube, and the experimental effect is great
SpecificationsTemp. Control Range: R.T.+5°C ~100°C
Temp. Setting Range: 5 °C ~ 100 °C
Temp. Uniformality @ 60 °C: ±1 °C
Temp. Display Accuracy: 0.1 °C
Heating Speed: ≤30 min (40 °C to 100 °C )
Time Range: 1 min~99 h 59 min
Accommodates Sample: 12
Test tube range: Φ10~29 mm/ Liquid volume 1~50 ml
Needle Plate Max. Lift Stroke: 200 mm
Gas-in Joint Outer Diameter: Φ7 mm
Maximum gas pressure: 0.2 MPa
Maximum gas flow: 15 L/min
Needle Length: 100 mm
Inner dimension: 260 x 150 mm
Voltage: AC 220 V, 50/60 Hz
Power: 1000 W
Fuse: 250V, 8A, Φ5 x 20
Dimension (WxDxH): W.390 x D.300 x H.850 mm
Net Weight: 9.5 kgs
Technical Characteristics / Specifications- Temp. Control Range: R.T.+5°C ~100°C
- Temp. Setting Range: 5 °C ~ 100 °C
- Temp. Uniformality @ 60 °C: ±1 °C
- Temp. Display Accuracy: 0.1 °C
- Heating Speed: ≤30 min (40 °C to 100 °C )
- Time Range: 1 min~99 h 59 min
- Accommodates Sample: 12
- Test tube range: Φ10~29 mm/ Liquid volume 1~50 ml
- Needle Plate Max. Lift Stroke: 200 mm
- Gas-in Joint Outer Diameter: Φ7 mm
- Maximum gas pressure: 0.2 MPa
- Maximum gas flow: 15 L/min
- Needle Length: 100 mm
- Inner dimension: 260 x 150 mm
- Voltage: AC 220 V, 50/60 Hz
- Power: 1000 W
- Fuse: 250V, 8A, Φ5 x 20
- Dimension (WxDxH): W.390 x D.300 x H.850 mm
- Net Weight: 9.5 kgs