Laboratory concentrator CON15-SC
samplebenchtop

Laboratory concentrator - CON15-SC - labstac - sample / benchtop
Laboratory concentrator - CON15-SC - labstac - sample / benchtop
Add to favorites
Compare this product

Characteristics

Applications
sample, laboratory
Other characteristics
benchtop

Description

Product Overview
Concentrator refers to the amount of a substance in a defined space. Concentration is especially used for concentrating or preparing sample in batches in laboratory.
  • Used in Drug screening, hormone analysis, liquid phase
  • Also known as Laboratory Concentrator

Key Features
  • The height of the air chamber plate can be adjusted. The length of a standard gas needle is 150 mm
  • LED displays immediate temperature and operation is simple and convenient
  • Built in overheat protection, automatic fault detection and alarm devices
  • The entire equipment can be put into ventilation cabin when concentration sample is in toxic solvents
  • Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the surface accelerates liquid evaporator sample concentration
  • Unique patented design for air channel control system, enhances air tightness and reduces potential leakage; easy to operate air needle to realize channel switch; the switching state/channel is clear at a glance

Specifications
Temp. Control Range: R.T.+5°C ~100°C
Temp. Setting Range: 5 °C ~ 150 °C
Temp. Stability @ 40 ~100 °C: ±0.5 °C
Temp. Stability @ 100~150 °C: ±1 °C
Block Temp. Uniformity @ 100 °C: ±0.5 °C
Block Temp. Uniformity @ 150 °C: ±1 °C
Temp. Display Accuracy: 0.1 °C
Heating Speed: ≤30 min (40 °C to 150 °C )
Time Range: 1 min ~99 h 59 min
Needle Plate Max. Lift Stroke: 285 mm
Gas-in Joint Outer Diameter: Φ7 mm
Nitrogen Pressure: ≤0.1 MPa
Nitrogen Flow Rate: 0~10 L/min
Needle Length: 150 mm
Sample Capacity: 1 standard block
Voltage: AC 220 V/AC 110 V, 50/60 Hz
Power: 200 W
Fuse: 250 V, 2 A / 3 A, Φ5 x 20
Dimension (WxDxH): W.200xD.230xH.525 mm
Net Weight: 5.1 kgs

Optional Accessories
Accessory Code | Name | Specification | Dia. of hole | Hole bottom shape | Block dimension
3800507005 | Block | 6 mm x 12 | 6.5 mm | Round bottom | 95.5x76.5x50 mm
3800507006 | Block | 7 mm x 12 | 7.5 mm | Round bottom | 95.5x76.5x50 mm
3800507010 | Block | 15 mm x 12(7ml tube) | 15.5 mm | Round bottom | 95.5x76.5x50 mm
3800507011 | Block | 16 mm x 12(10ml/15ml tube) | 16.5 mm | Round bottom | 95.5x76.5x50 mm
3800507012 | Block | 19 mm x 12 | 19.5 mm | Round bottom | 95.5x76.5x50 mm
3800507013 | Block | 20 mm x 6 | 20.5 mm | Round bottom | 95.5x76.5x50 mm
3800507018 | Block | 1.5 ml x 12 | 10.8 mm | Round bottom | 95.5x76.5x50 mm
3800507019 | Block | 2.0 ml x 12 | 10.8 mm | Round bottom | 95.5x76.5x50 mm
3800507020 | Block | 0.2 ml x 12 | 6.1 mm | Round bottom | 95.5x76.5x50 mm
3800507021 | Block | Customized | Customized | Round bottom | 95.5x76.5x50 mm
3800507007 | Block | 10 mm x 12 | 10.5 mm | Round bottom | 95.5x76.5x50 mm
3800507008 | Block | 12 mm x 12 | 12.5 mm | Round bottom | 95.5x76.5x50 mm
3800507009 | Block | 13 mm x 12 | 13.5 mm | Round bottom | 95.5x76.5x50 mm
3800507014 | Block | 26 mm x 6 | 26.5 mm | Round bottom | 95.5x76.5x50 mm
3800507015 | Block | 28 mm x 4(50ml tube) | 28.5 mm | Flat bottom | 95.5x76.5x50 mm
3800507016 | Block | 40 mm x 2 | 40.5 mm | Round bottom | 95.5x76.5x50 mm
3800507017 | Block | 0.5 ml x 12 | 8 mm | Cone bottom | 95.5x76.5x50 mm

Technical Characteristics / Specifications
  • Temp. Control Range: R.T.+5°C ~100°C
  • Temp. Setting Range: 5 °C ~ 150 °C
  • Temp. Stability @ 40 ~100 °C: ±0.5 °C
  • Temp. Stability @ 100~150 °C: ±1 °C
  • Block Temp. Uniformity @ 100 °C: ±0.5 °C
  • Block Temp. Uniformity @ 150 °C: ±1 °C
  • Temp. Display Accuracy: 0.1 °C
  • Heating Speed: ≤30 min (40 °C to 150 °C )
  • Time Range: 1 min ~99 h 59 min
  • Needle Plate Max. Lift Stroke: 285 mm
  • Gas-in Joint Outer Diameter: Φ7 mm
  • Nitrogen Pressure: ≤0.1 MPa
  • Nitrogen Flow Rate: 0~10 L/min
  • Needle Length: 150 mm
  • Sample Capacity: 1 standard block
  • Voltage: AC 220 V/AC 110 V, 50/60 Hz
  • Power: 200 W
  • Fuse: 250 V, 2 A / 3 A, Φ5 x 20
  • Dimension (WxDxH): W.200xD.230xH.525 mm
  • Net Weight: 5.1 kgs

Catalogs

No catalogs are available for this product.

See all of labstac‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.