Product DetailsConcentrator refers to the amount of a substance in a defined space. Concentration is especially used for concentrating or preparing sample in batches in laboratory.
- Used in Drug screening, hormone analysis, liquid phase
- Also known as Laboratory Concentrator
Key Features- The heater heats the sample rapidly to the evaporation temperature, and at the same time, the gas is blown to the surface of the solution through the gas needle, which promotes rapid evaporation of the solution and concentration of the sample
- The height of the air cavity can be adjusted. The length of a standard gas needle is 80 mm
- The entire equipment can be put into ventilation cabinet when the concentration sample in toxic solvents
- Built in overheat protection, automatic fault detection and fault beep alarm devices
- LED displays immediate temperature and diminishing time. Operation is simple
SpecificationsTemp. Control Range: R.T.+5°C ~100°C
Temp. Setting Range: 5 °C ~ 150 °C
Temp. Stability @ 40 ~100 °C: ±0.5 °C
Temp. Stability @ 100~150 °C: ±1 °C
Block Temp. Uniformity @ 100°C: ±0.5 °C
Block Temp. Uniformity @ 150 °C: ±1 °C
Temp. Display Accuracy: 0.1 °C
Heating Speed: ≤30 min (40 °C to 150 °C )
Time Range: 1 min ~99 h 59 min
Air cavity Max. Lift Stroke: 275 mm
Gas-in Joint Outer Diameter: Φ7 mm
Nitrogen Pressure: ≤0.1 MPa
Nitrogen Flow Rate: 0~10 L/min
Needle Length: 80 mm
Sample Capacity: 1 standard plate block
Voltage: AC 220 V/AC 110 V, 50/60 Hz
Power: 400 W
Fuse: 250 V, 2 A / 3 A, Φ5 x 20
Dimension (WxDxH): W.220xD.260xH.445 mm
Net Weight: 5.5 kgs
Optional AccessoriesAccessory Code: 3800506005 | Name: Block 17 | Suitable Concentrator: NDK200-1A | Description: 0.2ml x 96 PCR plate | Dimension: 78x114x26 mm
Accessory Code: 3800506006 | Name: Block 18 | Suitable Concentrator: NDK200-1A | Description: flat bottom plate block | Dimension: 81x123x19 mm
Caractéristiques / Spécifications techniques- Model: CON13-96
- Temp. Control Range: R.T.+5°C ~100°C
- Temp. Setting Range: 5 °C ~ 150 °C
- Temp. Stability @ 40 ~100 °C: ±0.5 °C
- Temp. Stability @ 100~150 °C: ±1 °C
- Block Temp. Uniformity @ 100°C: ±0.5 °C
- Block Temp. Uniformity @ 150 °C: ±1 °C
- Temp. Display Accuracy: 0.1 °C
- Heating Speed: ≤30 min (40 °C to 150 °C )
- Time Range: 1 min ~99 h 59 min
- Air cavity Max. Lift Stroke: 275 mm
- Gas-in Joint Outer Diameter: Φ7 mm
- Nitrogen Pressure: ≤0.1 MPa
- Nitrogen Flow Rate: 0~10 L/min
- Needle Length: 80 mm
- Sample Capacity: 1 standard plate block
- Voltage: AC 220 V/AC 110 V, 50/60 Hz
- Power: 400 W
- Fuse: 250 V, 2 A / 3 A, Φ5 x 20
- Dimension (WxDxH): W.220xD.260xH.445 mm
- Net Weight: 5.5 kgs