1. Products
  2. Laboratory evaporator
  3. MSP, a Division of TSI
video corpo

Laboratory vaporizer Turbo II™ 2852NP

Laboratory vaporizer - Turbo II™ 2852NP - MSP, a Division of TSI
Laboratory vaporizer - Turbo II™ 2852NP - MSP, a Division of TSI
Laboratory vaporizer - Turbo II™ 2852NP - MSP, a Division of TSI - image - 2
Laboratory vaporizer - Turbo II™ 2852NP - MSP, a Division of TSI - image - 3
Laboratory vaporizer - Turbo II™ 2852NP - MSP, a Division of TSI - image - 4
Add to favorites
Compare this product

fo_shop_gate_exact_title

Characteristics

Applications
laboratory

Description

MSP's Turbo II™ Vaporizer 2852NP is designed for applications that require low to mid vapor flow rates. Based off of the field proven, highly reliable, and low-maintenance MSP Turbo™ Vaporizers, the new 2852NP provides stable vapor concentrations while maintaining a very small footprint. The 2852NP also has a liquid shut-off valve, and can be used with any liquid flow controller that has an integrated flow control valve. - Dimensions: 190 mm x 84 mm x 114 mm (7.5'' x 3.3'' x 4.5'') - Weight: 2.5 kg (5.6 lb) - Fittings: Carrier Gas Inlet - 1/4 in. VCR female split nut, Liquid Inlet - 1/8 in. VCR female, Vapor Outlet - 1/4 in. VCR female split nut, Compressed Air - 4 mm instant tube fitting - Wetted Parts: SS 316, PEEK, Elgiloy®, Nickel - Leak Integrity: ≤ 1x 10^-8 Pa·m^3/s Helium - Heater Power Requirements: 208 VAC, 60 Hz, 450 W - Carrier Gas: Inert gas recommended - Max Carrier Gas Flow: 2.0 standard liters/min N2 @ 50 psig - Max Liquid Flow: 7 g/min (TEOS or equivalent) - System Pressure Limit: 150 psig - Compressed Air: 90 to 110 psig - Temperature Range: 40°C to 180°C - Temperature Sensor: 2 type Ƙ thermocouples - Accessories: Power cable included (3 m). AMP CPC, 4 pin connector with 3 flying leads on opposite end Specifications subject to change without notice. Max Carrier Flow, Heater Power (W) and Line Voltage are factory adjustable, visit www.tsi.com/contact to request more information. Max. liquid flow is process dependent. The spec assumes a vaporizer temperature of 180°C, max. carrier gas flow and pressure <50 Torr immediately downstream of the vaporizer. Appropriate venting is required.

Catalogs

No catalogs are available for this product.

See all of MSP, a Division of TSI‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.