video corpo

Real-time PCR system MQ96-X4
fluorescence96-wellfor fast PCR

real-time PCR system
real-time PCR system
Add to favorites
Compare this product
 

Characteristics

Technology
real-time, fluorescence
Number of wells
96-well
Applications
for fast PCR, for genotyping, for sequencing, for molecular diagnostic
Block format
interchangeable
Configuration
portable, mobile
Other characteristics
with touchscreen, high-performance, with heating block, wireless
Temperature range

Min.: 15 °C
(59 °F)

Max.: 100 °C
(212 °F)

Weight

30.5 kg
(67.24 lb)

Description

MQ96-X4 is a special instrument for real-time fluorescence detection. it integrates PCR amplification, fluorescence detection and data analysis. it can monitor the growth process of fluorescence quantity in each test tube in real time at the same time as the amplification. After the amplification, the software automatically processes the experimental data,carries on the quantitative / qualitative, melting curve or genotyping analysis to the sample, displays and prints the experimental results such as the initial concentration of the sample. Technical Specification Excitation light source: 4 monochrome high efficiency LED Fluorescence channel number: 4-channel Supporting dye: F1: FAM/SYBR Green etc. F2: Cy5 etc. F3: VIC/HEX/JOE /TET etc. F4: FAM/SYBR Green etc. F5: ROX/Texas Red etc. Detection device: Highly sensitive silicon photomultiplier(MPPC) Detection mode: Time resolved real-time scanning Fluorescence reading position: Top read Excitation/detection range: - 455-680nm Sensitivity: Single copy gene Resolution: In the single reaction, 1.33 times copy number difference can be distinguished Dynamic range: - Top read Excitation/detection range: - Ten orders of magnitude(1-1010 copy) Temperature control Sample capacity: 96 Thermal cycling technique: - Peltier Reaction volume: 10-50μl Maximum module rise and cooling rate: 4℃/s Temperature range: - 15-100 ℃ Temperature accuracy: ≤±0.2℃ Hot cover technique: Adjustable from room temperature to 115℃ Temperature uniformity: Top read Excitation/detection range: - ≤±0.2℃ Number of temperature gradient: 12 columns Temperature gradient range of temperature difference: - 0-24 ℃ Dimension: - 480*360*365mm Weight: - 30.5KG
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.