Bone densitometry test phantom BMD
for tomographyfor CT scanfor radiography

Bone densitometry test phantom - BMD - Pure Imaging Phantoms - for tomography / for CT scan / for radiography
Bone densitometry test phantom - BMD - Pure Imaging Phantoms - for tomography / for CT scan / for radiography
Bone densitometry test phantom - BMD - Pure Imaging Phantoms - for tomography / for CT scan / for radiography - image - 2
Bone densitometry test phantom - BMD - Pure Imaging Phantoms - for tomography / for CT scan / for radiography - image - 3
Add to favorites
Compare this product

Characteristics

Type of calibration
for bone densitometry, for tomography, for CT scan, for radiography
Area of the body
spine, general purpose, femur, whole body

Description

Overview
Precision-engineered rod phantoms for quantitative bone mineral density (BMD) calibration in CT and micro-CT systems. Manufactured using calcium hydroxyapatite (CaHA) embedded in a stable matrix, supplied as paired rods at defined mineral concentrations to ensure reproducible reference points for BMD analysis.

General details
  • Each set includes paired rods at 0.3 g/cm³ and 1.25 g/cm³ CaHA for calibration across a clinically and preclinically relevant density range.
  • Multiple diameters available to accommodate specimen sizes from small-animal models to human-scale samples.
  • Compatible with clinical CT, micro-CT and other X-ray imaging systems for quantitative BMD calibration and validation.

Specification
Small Diameter Set (2 mm – 4 mm)
Designed for high-resolution imaging of small specimens:
  • 2 mm rods: for very small bones such as mouse models
  • 4 mm rods: for small-animal studies including rat bones
  • Enables precise calibration in micro-CT systems with fine voxel sizes

Medium Diameter Set (8 mm – 16 mm)
Versatile option for mid-sized specimens:
  • Suitable for rabbit, sheep and human tissue samples
  • Balances resolution and signal for standard CT and micro-CT applications
  • Ideal for translational research and preclinical studies

Large Diameter Set (32 mm)
Optimised for larger anatomical structures:
  • Designed for human and large-animal bones, including vertebrae
  • Provides robust signal and uniformity in clinical CT environments
  • Ensures accurate BMD calibration at larger field-of-view settings

Key Features
  • Dual-density rods: 0.3 and 1.25 g/cm³ CaHA
  • Multiple diameters for species- and specimen-specific applications
  • Designed for stability and reproducibility
  • Compatible with CT, micro-CT and other X-ray imaging systems
  • Provided as paired rods per set for direct comparative calibration

Applications
  • Bone mineral density calibration
  • Longitudinal preclinical bone studies
  • Clinical CT quality assurance (QA)
  • Cross-system and multi-site standardization

CT Images
Representative CT and micro-CT slices and renderings illustrating rod placement, contrast and imaging performance for the different diameters and densities are available to support protocol optimization.

Technical specifications
  • Material: Calcium hydroxyapatite (CaHA) embedded in a stable matrix
  • Mineral concentrations: paired rods at 0.3 g/cm³ and 1.25 g/cm³ CaHA
  • Available diameters/sets: Small 2 mm–4 mm; Medium 8 mm–16 mm; Large 32 mm
  • Intended modalities: Clinical CT, micro-CT, other X-ray imaging systems
  • Primary uses: Quantitative BMD calibration, QA, preclinical longitudinal studies, cross-site standardization
  • Form factor: Rod phantoms supplied as paired rods per set