OverviewPrecision-engineered rod phantoms for quantitative bone mineral density (BMD) calibration in CT and micro-CT systems. Manufactured using calcium hydroxyapatite (CaHA) embedded in a stable matrix, supplied as paired rods at defined mineral concentrations to ensure reproducible reference points for BMD analysis.
General details- Each set includes paired rods at 0.3 g/cm³ and 1.25 g/cm³ CaHA for calibration across a clinically and preclinically relevant density range.
- Multiple diameters available to accommodate specimen sizes from small-animal models to human-scale samples.
- Compatible with clinical CT, micro-CT and other X-ray imaging systems for quantitative BMD calibration and validation.
SpecificationSmall Diameter Set (2 mm – 4 mm)Designed for high-resolution imaging of small specimens:
- 2 mm rods: for very small bones such as mouse models
- 4 mm rods: for small-animal studies including rat bones
- Enables precise calibration in micro-CT systems with fine voxel sizes
Medium Diameter Set (8 mm – 16 mm)Versatile option for mid-sized specimens:
- Suitable for rabbit, sheep and human tissue samples
- Balances resolution and signal for standard CT and micro-CT applications
- Ideal for translational research and preclinical studies
Large Diameter Set (32 mm)Optimised for larger anatomical structures:
- Designed for human and large-animal bones, including vertebrae
- Provides robust signal and uniformity in clinical CT environments
- Ensures accurate BMD calibration at larger field-of-view settings
Key Features- Dual-density rods: 0.3 and 1.25 g/cm³ CaHA
- Multiple diameters for species- and specimen-specific applications
- Designed for stability and reproducibility
- Compatible with CT, micro-CT and other X-ray imaging systems
- Provided as paired rods per set for direct comparative calibration
Applications- Bone mineral density calibration
- Longitudinal preclinical bone studies
- Clinical CT quality assurance (QA)
- Cross-system and multi-site standardization
CT ImagesRepresentative CT and micro-CT slices and renderings illustrating rod placement, contrast and imaging performance for the different diameters and densities are available to support protocol optimization.
Technical specifications- Material: Calcium hydroxyapatite (CaHA) embedded in a stable matrix
- Mineral concentrations: paired rods at 0.3 g/cm³ and 1.25 g/cm³ CaHA
- Available diameters/sets: Small 2 mm–4 mm; Medium 8 mm–16 mm; Large 32 mm
- Intended modalities: Clinical CT, micro-CT, other X-ray imaging systems
- Primary uses: Quantitative BMD calibration, QA, preclinical longitudinal studies, cross-site standardization
- Form factor: Rod phantoms supplied as paired rods per set