Radiography test phantom
for CT scanfor tomographyfor MRI

Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI
Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI
Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI - image - 2
Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI - image - 3
Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI - image - 4
Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI - image - 5
Radiography test phantom - Pure Imaging Phantoms - for CT scan / for tomography / for MRI - image - 6
Add to favorites
Compare this product

Characteristics

Type of calibration
for radiography, for CT scan, for tomography, for MRI, for ultrasound imaging
Area of the body
ear

Description

Product description: The Adult Ear Phantom reproduces the complex external and internal ear anatomy for research, development and testing of hearing‑related devices and acoustic systems. It is designed for multi‑modal imaging (MRI, CT/X‑Ray, Ultrasound) and can be customised to project specifications. Phantom tissues are manufactured to match realistic T2 relaxation times, optimising results for T2‑weighted MRI and providing very good Proton Density imaging performance. T1‑weighted imaging is achievable with realistic contrast within an approximate 100 ms range. The ear phantom is supplied as a stand‑alone unit or can be integrated into complete skull or head phantoms.

Anatomy:
  • Ear cartilage tissue
  • Bone with ear canal
  • Acoustically accurate skin‑mimicking tissue

Comes with:
  • Adult Ear Phantom
  • User manual and assembly instructions
  • 2‑year warranty and unlimited customer support
  • Hard carry case

CT scans: Provided CT images illustrate ear anatomy and bone/ear canal features for CT/X‑Ray evaluation.

Technical specifications:
  • Imaging modalities supported: MRI (T2‑weighted, Proton Density, T1‑weighted within ~100 ms), CT/X‑Ray, Ultrasound
  • Phantom tissues matched to realistic T2 relaxation times
  • Very good Proton Density imaging performance
  • T1‑weighted imaging realistic within ~100 ms
  • Customisable to project requirements
  • Available as stand‑alone or integrated into full skull/head phantoms
  • Includes user manual and assembly instructions
  • Includes 2‑year warranty and unlimited customer support
  • Supplied with hard carry case

Catalogs

No catalogs are available for this product.