Forced convection laboratory incubator Incucenter
benchtop1-doorheating

Forced convection laboratory incubator - Incucenter - Renggli AG / Salvislab - benchtop / 1-door / heating
Forced convection laboratory incubator - Incucenter - Renggli AG / Salvislab - benchtop / 1-door / heating
Forced convection laboratory incubator - Incucenter - Renggli AG / Salvislab - benchtop / 1-door / heating - image - 2
Forced convection laboratory incubator - Incucenter - Renggli AG / Salvislab - benchtop / 1-door / heating - image - 3
Forced convection laboratory incubator - Incucenter - Renggli AG / Salvislab - benchtop / 1-door / heating - image - 4
Add to favorites
Compare this product

Characteristics

Type
forced convection
Configuration
benchtop
Number of doors
1-door
Other characteristics
temperature-control, heating, high-temperature, with decontamination system
Temperature range

Max.: 110 °C
(230 °F)

Min.: 5 °C
(41 °F)

Capacity

40 l, 80 l, 160 l, 240 l, 400 l
(10.6 gal, 21.1 gal, 42.3 gal, 63.4 gal, 105.7 gal)

Description

Overview
SalvisLab Incucenter are precision laboratory incubators designed for clinical and industrial laboratories as well as quality control applications. The IntelliFan-System ensures uniform temperature distribution independent of load. The inner safety-glass door allows optical monitoring without heat loss. SalvisTEQ controller provides intuitive operation and process reliability.

Key features
  • SalvisTEQ controller with touch display
  • Fast heating and accurate temperature control
  • High energy efficiency
  • Supports decontamination up to +110 °C
  • Real-time clock with process time logging
  • Safety class 3.3
  • USB and RJ45 (LAN) interfaces
  • Standard 6 mm entry port (options available)
  • Fresh air filter and ambient temperature probe


Variants
IC40
  • External dimensions (W×H×D) mm: 650×510×510
  • Internal dimensions (W×H×D) mm: 385×370×305
  • Internal volume: 40 L
  • Shelves (standard/max): 2 / 5
  • Temperature range: approx. >5 °C above ambient to 110 °C
  • Temperature variation at 37/110 °C (±°C): 0.3 / 0.8
  • Temperature fluctuation at 37 °C (±°C): 0.2
  • Heating-up time to 37 °C: 10 min
  • Recovery time: 3 min
  • Power: 500 W
  • Controller: SalvisTEQ (touch)
  • Ports: USB, RJ45

IC80
  • External dimensions (W×H×D) mm: 750×540×600
  • Internal dimensions (W×H×D) mm: 485×400×395
  • Internal volume: 80 L
  • Shelves (standard/max): 2 / 5
  • Temperature range: approx. >5 °C above ambient to 110 °C
  • Temperature variation at 37/110 °C (±°C): 0.3 / 0.8
  • Temperature fluctuation at 37 °C (±°C): 0.2
  • Heating-up time to 37 °C: 14 min
  • Recovery time: 3 min
  • Power: 800 W
  • Controller: SalvisTEQ (touch)
  • Ports: USB, RJ45

IC160
  • External dimensions (W×H×D) mm: 800×720×680
  • Internal dimensions (W×H×D) mm: 535×580×475
  • Internal volume: 160 L
  • Shelves (standard/max): 2 / 8
  • Temperature range: approx. >5 °C above ambient to 110 °C
  • Temperature variation at 37/110 °C (±°C): 0.5 / 1.2
  • Temperature fluctuation at 37 °C (±°C): 0.2
  • Heating-up time to 37 °C: 20 min
  • Recovery time: 5 min
  • Power: 1000 W
  • Controller: SalvisTEQ (touch)
  • Ports: USB, RJ45

IC240
  • External dimensions (W×H×D) mm: 890×820×720
  • Internal dimensions (W×H×D) mm: 625×680×515
  • Internal volume: 240 L
  • Shelves (standard/max): 2 / 8
  • Temperature range: approx. >5 °C above ambient to 110 °C
  • Temperature variation at 37/110 °C (±°C): 0.5 / 1.8
  • Temperature fluctuation at 37 °C (±°C): 0.2
  • Heating-up time to 37 °C: 26 min
  • Recovery time: 5 min
  • Power: 1200 W
  • Controller: SalvisTEQ (touch)
  • Ports: USB, RJ45

IC400
  • External dimensions (W×H×D) mm: 990×920×900
  • Internal dimensions (W×H×D) mm: 725×780×695
  • Internal volume: 400 L
  • Shelves (standard/max): 2 / 10
  • Temperature range: approx. >5 °C above ambient to 110 °C
  • Temperature variation at 37/110 °C (±°C): 0.5 / 2.0
  • Temperature fluctuation at 37 °C (±°C): 0.2
  • Heating-up time to 37 °C: 33 min
  • Recovery time: 5 min
  • Power: 1200 W
  • Controller: SalvisTEQ (touch)
  • Ports: USB, RJ45


Options
  • Product temperature controller
  • Program and user package
  • Process graph (data logging)
  • Redundant PT-100 probe
  • LAN interface
  • Additional memory
  • Additional USB or RJ45 interface
  • Entry port 20 mm or 40 mm
  • IQ/OQ draft paper, 3 hard copies
  • Two freely assignable analog outputs
  • Programmable power socket
  • Calibration to + point
  • Potential-free contact


Accessories
  • Wire shelves (standard)
  • Fresh air filter
  • Product temperature probe PT-100


Technical specifications
  • Temperature range up to +110 °C (supports decontamination)
  • IntelliFan-System for uniform temperature distribution
  • Inner safety-glass door for optical process monitoring without heat loss
  • Real-time clock with process time logging
  • Safety class: 3.3
  • Interfaces: USB, RJ45 (LAN)
  • Display: Touch screen (SalvisTEQ controller)
  • Standard entry port: 6 mm (options: 20 mm, 40 mm)
  • Fresh air filter and ambient temperature probe
  • Model-specific data provided per model: IC40, IC80, IC160, IC240, IC400
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.