1. Medical Technical Facilities
  2. Monitoring
  3. NIBP simulator
  4. SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD

Blood pressure measurement simulator ZCE837
monitoringNIBPemergency care

Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care
Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care
Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care - image - 2
Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care - image - 3
Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care - image - 4
Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care - image - 5
Blood pressure measurement simulator - ZCE837  - SICHUAN ZHONGCE INSTRUMENT TECHNOLOGY CO.,LTD - monitoring / NIBP / emergency care - image - 6
Add to favorites
Compare this product

Characteristics

Procedure
for blood pressure measurement, monitoring, NIBP
Application
for general care, for clinical care, emergency care
Form
monitor
Configuration
portable
Technology
computerized
Options
with electronic console
Other characteristics
wireless

Description

Overview
The ZCE837 series non-invasive blood pressure simulator is designed for verification and calibration of non-invasive blood pressure (NIBP) monitors and patient monitors that use the oscillometric principle. It integrates an electric pressure pump, a high-precision pressure sensor and a programmable pulse simulator to reproduce physiological pressure and pulse waveforms.

Key features
  • Precise pressure generation for systolic, diastolic and mean arterial pressure simulation
  • Programmable pulse rate and pulse amplitude to reproduce physiological conditions
  • High-precision pressure sensor for stable and repeatable outputs
  • Electric pressure pump with controlled ramp and rapid response
  • Simple cuff connection and straightforward setup for test benches


Applications
  • Verification and calibration of oscillometric NIBP monitors
  • Manufacturing and final testing of patient monitors
  • Service centers and maintenance laboratories
  • Clinical engineering and hospital equipment acceptance testing


Technical components
  • Electric pressure pump, high-precision pressure sensor and programmable pulse generator
  • User controls for parameter adjustment and real-time readout
  • Output/cuff port and interfaces for integration with test systems


Benefits
  • Supports accurate, repeatable calibration routines
  • Helps ensure reliable NIBP measurements in clinical and manufacturing environments
  • Reduces device downtime by enabling on-site verification and maintenance


Ordering information
  • ZCE837 series units are available with optional calibration certificate and accessories
  • Contact the supplier for configuration, calibration and after-sales support