Blood glucose meter with speaking mode Safe AQ Voice
with lancing devicevoice

Blood glucose meter with speaking mode - Safe AQ Voice - Sinocare - with lancing device / voice
Blood glucose meter with speaking mode - Safe AQ Voice - Sinocare - with lancing device / voice
Blood glucose meter with speaking mode - Safe AQ Voice - Sinocare - with lancing device / voice - image - 2
Blood glucose meter with speaking mode - Safe AQ Voice - Sinocare - with lancing device / voice - image - 3
Add to favorites
Compare this product

Characteristics

Other characteristics
with lancing device, with speaking mode, voice
Result display time

5 s

Sample volume

0.0006 ml
(0 US fl oz)

Memory capacity

10 unit

Length

84 mm
(3.3 in)

Width

60 mm
(2.4 in)

Height

26 mm
(1 in)

Description

Intended use

  • The Safe AQ Voice blood glucose monitoring system is intended for in vitro diagnostic use only and must not be used for diagnosis or screening of diabetes.


Kit contents

  • Safe AQ Voice blood glucose meter
  • Safe AQ blood glucose test strips
  • Blood glucose control solution


Key features

  • FAD‑GDH enzyme system: minimally affected by blood oxygen.
  • Fast test time: results in ~5 seconds.
  • Patented painless lancing device and non‑interference design.
  • Voice prompt reporting and red/green light warning for ease of use.
  • Very small sample volume: 0.6 μL.
  • Electrochemical reaction example: C6H12O6 + K3Fe(CN)6 → FAD‑GDH → C6H12O7 + K4Fe(CN)6; K4Fe(CN)6 → K3Fe(CN)6 + e-


Technical specifications

  • Sample volume: 0.6 μL
  • Sample type: fresh capillary whole blood (also venous whole blood)
  • Calibration: plasma equivalent
  • Measurement range: 20–600 mg/dL (1.1–33.3 mmol/L)
  • Units: mg/dL or mmol/L
  • Hematocrit range: 30%–60%
  • Test strip shelf life: 24 months
  • Meter dimensions: 84 × 60 × 26 mm
  • Storage temperature (meter): -20 °C to 55 °C
  • Operating conditions: 10 °C to 35 °C; ≤ 80% relative humidity
  • Power: 2 × AAA alkaline batteries, 3V DC
  • Battery life: >1000 tests (typical)
  • Memory: stores 10 test results
  • Design: handheld
  • Estimated device service life: up to 10 years (based on 7 tests/day estimate)


Maintenance & user instructions

  • Users must perform routine maintenance and follow the instructions in the user manual.
  • Refer to the user manual for cleaning, calibration checks, replacement of consumables and safety information.
  • Comply with local regulations for medical devices and waste disposal.