Data transfer module PPG-2TF-660 2.0
data acquisitiondriverdata processing

Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing - image - 2
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing - image - 3
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing - image - 4
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing - image - 5
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing - image - 6
Data transfer module - PPG-2TF-660 2.0 - WhaleTeq Co., Ltd - data acquisition / driver / data processing - image - 7
Add to favorites
Compare this product

Characteristics

Function
data transfer, data acquisition, data processing, driver
Application
telemonitoring
Data
SpO2
Options
USB, electronic, for automation

Description

Overview
The PPG-2TF-660 2.0 Transmittance SpO2 module is a laboratory-grade signal generator designed for evaluation, validation and production testing of transmittance pulse oximeters when paired with the AECG100 main unit or the SECG 5.0 AIO Multi Vital Sign Simulator. It reproduces low-perfusion conditions down to a Perfusion Index (PI) of 0.01% and supports diverse skin-tone optical scenarios and high heart rates to enable repeatable SpO2 verification. The module allows establishment of device-specific SpO2 R curves and fine adjustment of waveform parameters for precise, repeatable algorithm verification.

Functions
  • Basic waveform output: PPG waveform, sine, triangle and square outputs with coarse and fine adjustments; DC offset testing supported.
  • PPG signal generation: Simultaneous red and infrared analog signals with adjustable characteristic points including Systolic Peak (SP), Dicrotic Notch (DN) and Diastolic Peak (DP).
  • Adjustable PWTT (Pulse Wave Transit Time): Synchronized ECG and PPG output with adjustable PTT timing differences (PTTp and PTTf) for algorithm validation.
  • Blood oxygen R-curve simulation: Create device-specific R curves to validate SpO2 and PI specifications; automatic calculation of red/IR DC references and custom R-curve generation.
  • Saving test parameters: Store parameters across test items for integrated, repeatable testing and reduced human error.
  • Raw data playback: Playback of raw waveform data and reproduction of clinically recorded or custom waveforms.
  • Simple automated test: Support for software-controlled automated testing and manual editing of auto-sequences for sequence tests.


Highlights
  • Wide testing range with broad light intensity adjustment and dynamic light detection to meet varied finger testing conditions.
  • Built-in reflectance table for simulating signals from different fingers and time-accurate, realistic scenarios.
  • 14 types of ambient light signal superposition and respiration variation simulations integrated.
  • Rapid DUT R-curve establishment for quality consistency testing; includes example R-curves from major manufacturers as reference.
  • Provided Software Development Kit (SDK) for flexible development of test programs and automated workflows.


Ordering & Package
  • Part No.: 100-AE00018
  • Model No.: PPG-2TF-660 2.0
  • Model Name: Transmittance SpO2 module
  • Package contents: PPG-2TF-660 2.0 x1; USB Type-C to Type-C cable (male to male, 150cm, black) x1; MCX (RF) male to BNC cable (30cm) x2.
  • Compatible main units: AECG100 (main console for ECG/PPG testing) and SECG 5.0 AIO (Multi Vital Sign Simulator).


Downloads / Documentation
Datasheet and user manuals available for the product and for pairing with AECG100 and SECG 5.0 AIO.

Technical Specifications
  • Heart Rate: Setting range 10—300 BPM; Minimum step 1 BPM; Accuracy ±1 BPM.
  • LED DC Level Reference Output: Setting range 300—3000 mV; Minimum step 1 mV.
  • LED AC Level Reference Output: Setting range 0.1—300 mV; Minimum step 0.01 mV.
  • PI (AC level / DC level): 0.01%—20% (varies with AC or DC level).
  • LED1 Absolute Irradiance (100%): 2.36 mW/m^2nm; Accuracy ±10%.
  • LED2 Absolute Irradiance (ambient light): 0.25 mW/m^2nm; Accuracy ±10%.
  • LED Scan Rate: 50—40 kHz (Normal mode / Standalone mode); 10 kHz (Raw data mode); timing accuracy ±5 μs.
  • PD Sample Rate: 250 kHz (Single channel); accuracy ±5 μs.
  • PD Response Time: Rising/Falling 1 μs typical (varies with DUT light intensity).
  • SpO2 Test Mode: Setting range 1%—100%; Minimum step 1%; Accuracy: 91%—100%: ±1% + specified DUT accuracy; 81%—90%: ±2% + DUT accuracy; 71%—80%: ±3% + DUT accuracy; Below 70%: unspecified accuracy.
  • SpO2 Test Mode Parameters (defaults): Output waveform PPG; BPM default 60 BPM; SpO2 default 98%.
  • Red channel defaults: PI range 0.01—20.000% (default 2.000%); AC 0.1—300 mV (default 12.50 mV); DC 300—3000 mV (default 625 mV); Output DC offset 0—2000 mV.
  • Infrared channel defaults: PI range 0.01—20.000% (default 4.000%); AC 0.1—300 mV (default 25.00 mV); DC 300—3000 mV (default 625 mV); Output DC offset 0—2000 mV.
  • PPG Test Mode Parameters: Output waveform Sine / Triangle / Square / PPG; BPM 10—300 BPM (default 60); Frequency 0.17—5 Hz (default 1.00); DC range 300—3000 mV (default 625 mV).
  • PPG Time Parameters (defaults): SP (Systolic Peak) time default 150 ms; DN (Dicrotic Notch) default 360 ms; DP (Diastolic Peak) default 460 ms; time resolution 1 ms.
  • Noise Generator (Time): Frequency options off / 0.5 / 1 / 2 / 3 / 5 / 10 / 25 / 50 / 60 / 100 / 120 / 1K / 5K Hz / White Noise; Amplitude 0.05—2.00 mV.
  • Respiration: Respiration rate 1—150 BrPM (default 20 BrPM); Inhale-Exhale ratio options 1:1–1:5; Wave modulation: Baseline / Amplitude / Frequency; Baseline modulation variation R/IR 1—16% (default 1%).
  • Apnea selection: Duration 1—60 s (default 10 s); Cycle 1—10 min (default 1 min).
  • Auto Test (SpO2 Test Mode) Parameters: BPM 10—300 BPM; SpO2 0—100% (default 98%); IR–PI 0.01—20% (default 2.4%); Transmission rate presets for neonatal, dark & thick finger, dark medium, normal medium, light & medium, light & thin finger (default Normal Medium Finger).
  • Data collection method note: Use a spectrometer with a 2-inch integrating sphere fixed on the DUT to measure LED absolute irradiance; when paired with AECG100 supports Normal / Standalone / Raw data modes; when paired with SECG 5.0 AIO only Raw data mode applies.